Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TR 38.835  Word version:  18.0.1

Top   Top   Up   Prev   Next
1…   4…   5…   6   A   B…   B.1.2   B.1.3   B.1.4   B.1.5   B.1.6   B.1.7   B.1.8   B.1.9   B.1.10   B.2…   B.2.2   B.2.3   B.2.4   B.2.5   B.2.6   B.2.7   B.2.8   B.2.9   B.2.10   B.2.11   B.2.12   B.2.13   B.2.14   B.2.15   B.2.16   B.2.17   B.2.18   C…

 

B.2.8  Multiple active CDRX configurationsp. 85

This clause captures evaluation results for multiple active CDRX configurations for multiple XR traffic flows.
  • Ericsson and InterDigital evaluated the multiple active CDRX configurations separately for XR video and the other traffics.
  • vivo compared multiple active CDRX configurations and a single active CDRX configuration with SPS or a single active CDRX configuration only.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of DL satis­fied UE% of UL satis­fied UE% of DL + UL satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
EricssonR1-2210922Always On---H55--94.0%0.0%0%0%
EricssonR1-2210922R15/16 DRX (Long DRX)1084H55--90.7%-3.5%3.0%3.3%
EricssonR1-2210922R15/16 DRX (Short DRX)424H55--85.9%-8.6%6.9%7.2%
EricssonR1-2210922Matched CDRX33.3104H55--0%-100.0%18.4%-Note 2
EricssonR1-2210922Multi-flow DRX & Matched CDRX33.3104H55--88.4%-6.0%13.4%13.6%Note1,2
EricssonR1-2210922Multi-flow DRX & two-stage DRX & Matched CDRXouter DRX: 33.3;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4H55--81.8%-13.0%16.9%17.2%Note2,3
NOTE 1:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 0ms.
NOTE 2:
Matched CDRX has (drx_offset=3, traffic_time_offset=1 ms, drx-LongCycle=33 ms)
NOTE 3:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 4ms.
Based on the evaluation results in Table B.2.8-1, the following observations can be made:
  • For FR1, DL + UL joint evaluation, DU, high load, VR 30Mbps traffic at 30fps with 10ms PDB and DL audio with 10ms PDB, it is observed from Ericsson that:
    • eCDRX with a single CDRX configuration provides:
      • power saving gain of 18.4% for all UEs
      • capacity gain of -100%
    • Multiple CDRX configurations + eCDRX provides:
      • power saving gain of 13.4%
      • capacity gain of -6.0%
    • Multiple CDRX configurations + eCDRX + two-stage DRX provides:
      • power saving gain of 17.2%
      • capacity gain of -13.0%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of DL satis­fied UE% of UL satis­fied UE% of DL + UL satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
EricssonR1-2210922Always On---H77--90.1%0.0%--
EricssonR1-2210922R15/16 DRX (Long DRX)1084H77--86.3%-4.2%2.7%2.6%
EricssonR1-2210922R15/16 DRX (Short DRX)424H77--78.7%-12.7%6.4%6.4%
EricssonR1-2210922Matched CDRX22.2104H77--0%-100.0%12.3%-Note 2
EricssonR1-2210922Multi-flow DRX & Matched CDRX22.2104H77--85.9%-4.7%10.1%10.0%Note1,2
EricssonR1-2210922Multi-flow DRX & two-stage DRX & Matched CDRXouter DRX: 22.2;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4H77--71.3%-20.9%13.1%12.8%Note1,2
NOTE 1:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 0ms.
NOTE 2:
Matched CDRX has (drx_offset=9, traffic_time_offset=2 ms, drx-LongCycle=22 ms)
Based on the evaluation results in Table B.2.8-2, the following observations can be made:
  • For FR1, DL + UL joint evaluation, DU, high load, VR 45Mbps traffic at 30fps with 10ms PDB and DL audio with 10ms PDB, it is observed from Ericsson that:
    • eCDRX with a single CDRX configuration provides:
      • power saving gain of 12.3% for all UEs
      • capacity gain of -100%
    • Multiple CDRX configurations + eCDRX provides:
      • power saving gain of 10.1%
      • capacity gain of -4.7%
    • Multiple CDRX configurations + eCDRX + two-stage DRX provides:
      • power saving gain of 13.1%
      • capacity gain of -20.9%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
vivoR1-2211024Always On---L510100%0%--
vivoR1-2211024One active CDRX for video16.6784L510100%0%11.70%-
vivoR1-2211024One active CDRX for video and SPS for audio16.6784L510100%0%9.81%-
vivoR1-2211024Multiple CDRXs16.6784L510100%0%9.72%-Note1
vivoR1-2211024Multiple CDRXs16.6784L510100%0%9.52%-Note2
vivoR1-2211024Always On---H101092.09%0.0%--
vivoR1-2211024One active CDRX for video16.6784H101091.07%-1.1%9.23%-
vivoR1-2211024One active CDRX for video and SPS for audio16.6784H101091.66%-0.5%8.14%-
vivoR1-2211024Multiple CDRXs16.6784H101091.02%-1.2%8.04%-Note1
vivoR1-2211024Multiple CDRXs16.6784H101091.46%-0.7%6.95%-Note2
NOTE 1:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 0ms.
NOTE 2:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 2ms.
Based on the evaluation results in Table B.2.8-3, the following observations can be made:
  • For FR1, DL-only evaluation, InH, high load, VR 30Mbps traffic at 60fps with 10ms PDB and DL audio, it is observed from vivo that:
    • multiple CDRX configurations with eCDRX provides:
      • mean power saving gain of 7.50% in the range of 6.95% to 8.04%
      • mean capacity gain of -0.95% in the range of -1.2% to -0.7%
    • single eCDRX + SPS performance reference provides:
      • power saving gain of 8.14%
      • capacity gain of -0.5%
    • single eCDRX performance reference provides:
      • power saving gain of 9.23%
      • capacity gain of -1.1%
  • For FR1, DL-only evaluation, InH, low load, VR 30Mbps traffic at 60fps with 10ms PDB and DL audio, it is observed from vivo that:
    • multiple CDRX configurations with eCDRX provides:
      • mean power saving gain of 9.62% in the range of 9.52% to 9.72%
      • mean capacity gain of 0%
    • single eCDRX + SPS performance reference provides:
      • power saving gain of 9.81%
      • mean capacity gain of 0%
    • single eCDRX performance reference provides:
      • power saving gain of 11.70%
      • capacity gain of 0%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
InterDigital5R1-2211842Always On---H3391.70%0.0%0.0%-
InterDigital6R1-2211842Single CDRX Config1082H3383.30%-9.2%6.22%-
InterDigital7R1-2211842Multi-CDRX Config Set 133106H3372.20%-21.3%12.82%-Note1
InterDigital7R1-2211842Multi-CDRX Config Set 133106H3372.20%-21.3%6.97%-Note1,6
InterDigital8R1-2211842Multi-CDRX Config Set 233124H3372.20%-21.3%18.09%-Note2
InterDigital8R1-2211842Multi-CDRX Config Set 233124H3372.20%-21.3%12.54%-Note2,6
vivoR1-2211024Always On---L36100%0.0%0.0%-Note5
vivoR1-2211024One active CDRX for video33.3384L360.00%-100.0%41.06%-Note5
vivoR1-2211024One active CDRX for video and SPS for audio33.3384L36100%0.0%20.70%-Note5
vivoR1-2211024Multiple CDRXs33.3384L36100%0.0%19.84%-Note3,5
vivoR1-2211024Multiple CDRXs33.3384L36100%0.0%18.81%-Note4,5
vivoR1-2211024Always On---H6694.91%0.0%0.0%-Note5
vivoR1-2211024One active CDRX for video33.3384H660.00%-100.0%37.32%-Note5
vivoR1-2211024One active CDRX for video and SPS for audio33.3384H6694.44%-0.5%19.02%-Note5
vivoR1-2211024Multiple CDRXs33.3384H6693.98%-1.0%18.34%-Note3,5
vivoR1-2211024Multiple CDRXs33.3384H6694.44%-0.5%16.85%-Note4,5
NOTE 1:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 6ms.
NOTE 2:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 4ms.
NOTE 3:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 0ms.
NOTE 4:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 2ms.
NOTE 5:
DL audio has 10ms PDB
NOTE 6:
PSG is calculated w.r.t. single CDRX scheme
Based on the evaluation results in Table B.2.8-4, the following observations can be made:
  • For FR1, DL only evaluation, InH, high load, AR 30Mbps traffic at 30fps with 10ms PDB and DL audio, it is observed from InterDigital that:
    • Multiple CDRX configurations provides:
      • mean power saving gain of 15.54% in the range of 12.82% to 18.09%
      • mean capacity gain of -21.3%
    • performance reference a single CDRX configuration provides:
      • power saving gain of 6.22% for all UEs
      • capacity gain of -9.2%
  • For FR1, DL-only evaluation, InH, high load, VR 30Mbps traffic at 30fps with 10ms PDB and DL audio with 10ms PDB, it is observed from vivo that:
    • multiple CDRX configurations with eCDRX provides:
      • mean power saving gain of 17.60% in the range of 16.85% to 18.34%
      • mean capacity gain of -0.75% in the range of -1.0% to -0.5%
    • performance reference single eCDRX + SPS provides:
      • power saving gain of 19.02%
      • capacity gain of -0.5%
    • performance reference single eCDRX provides:
      • power saving gain of 37.32%
      • capacity gain of -100%
  • For FR1, DL-only evaluation, InH, low load, VR 30Mbps traffic at 30fps with 10ms PDB and DL audio with 10ms PDB, it is observed from vivo that:
    • multiple CDRX configurations with eCDRX provides:
      • mean power saving gain of 19.33% in the range of 18.81% to 19.84%
      • capacity gain of 0%
    • performance reference single eCDRX + SPS provides:
      • power saving gain of 20.70%
      • capacity gain of 0%
    • performance reference single eCDRX provides:
      • power saving gain of 41.06%
      • capacity gain of -100%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
InterDigital1R1-2211842Always On---H33100%0.0%0.0%-
InterDigital2R1-2211842Single CDRX Config1082H33100%0.0%7.647%-
InterDigital3R1-2211842Multi-CDRX Config Set 133106H3394.40%-5.6%12.082%-Note1
InterDigital3R1-2211842Multi-CDRX Config Set 133106H3394.40%-5.6%4.73%-Note1,3
InterDigital4R1-2211842Multi-CDRX Config Set 233124H3391.70%-8.3%17.16%-Note2
InterDigital4R1-2211842Multi-CDRX Config Set 233124H3391.70%-8.3%10.23%-Note2,3
NOTE 1:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 6ms.
NOTE 2:
for the second CDRX, CDRX cycle = 10ms, ODT = 2ms, IAT = 4ms.
NOTE 3:
PSG is calculated w.r.t. single CDRX scheme
Based on the evaluation results in Table B.2.8-5, the following observations can be made:
  • For FR1, DL only evaluation, InH, high load, CG 30Mbps traffic at 30fps with 15ms PDB and DL audio, it is observed from InterDigital that:
    • single CDRX configuration provides:
      • power saving gain of 7.647% for all UEs
      • capacity gain of 0%
    • Multiple CDRX configurations provides:
      • mean power saving gain of 14.62% in the range of 12.08% to 17.16%
      • mean capacity gain of -6.95% in the range of -8.3% to -5.6%
Up

Up   Top   ToC