B.2.7  Additional DRX active timep. 77

This clause captures evaluation results for additional DRX active time.
  • ZTE evaluated the extension for additional active time if UE does not receive UE specific data scheduled by a PDCCH CRC scrambled by the XR-specific RNTI within current active time.
  • OPPO evaluated additional On Duration triggered by dynamic signaling such as a DCI to receive data that arrives after the On Duration expires.
  • Nokia evaluated the Extension of Active Time (EAT) to extend DRX active time if XR frame does not arrive before the On Duration timer expires.
  • vivo compared the additional DRX active time and R17 PDCCH monitoring adaptation scheme.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of DL satis­fied UE% of UL satis­fied UE% of DL + UL satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE52R1-2212596Always on---H1111--90.15%0.00%0%-Note 1
ZTE15R1-2212596Aligned CDRXAligned every 50ms124H111188.36%100%88.36%-1.99%7.5%-Note 1
ZTE16R1-2212596Additional active time + aligned CDRXAligned every 50ms54H111190%100%90%-0.17%14.18%-Note 1,2
NOTE 1:
Jitter range = [-8,8]ms
NOTE 2:
additional active time = original DRX On duration
Based on the evaluation results in Table B.2.7-1, the following observations can be made:
  • For FR1, DL and UL joint evaluation, InH, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from ZTE that:
    • on top of eCDRX, additional active time provides:
      • power saving gain of 14.18% for all UEs
      • capacity gain of -0.17%.
    • eCDRX as the performance reference provides:
      • power saving gain of 7.5% for all UEs
      • capacity gain of -1.99%.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of DL satis­fied UE% of UL satis­fied UE% of DL + UL satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE54R1-2212596Always on---H77--90.48%0.00%--Note 1
ZTE19R1-2212596Aligned CDRXAligned every 50ms125H7790%100%90%-0.53%7.5%-Note 1
ZTE20R1-2212596Additional active time + aligned CDRXAligned every 50ms65H7788.1%100%88.1%-2.63%15.16%-Note 1,2
NOTE 1:
Jitter range = [-8,8]ms
NOTE 2:
additional active time = original DRX On duration
Based on the evaluation results in Table B.2.7-2, the following observations can be made:
  • For FR1, DL and UL joint evaluation, InH, high load, VR 45Mbps traffic at 60fps and 10ms PDB, it is observed from ZTE that:
    • on top of eCDRX, additional active time provides:
      • power saving gain of 15.16% for all UEs
      • capacity gain of -2.63%.
    • eCDRX as the performance reference provides:
      • power saving gain of 7.5% for all UEs
      • capacity gain of -0.53%.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of DL satis­fied UE% of UL satis­fied UE% of DL + UL satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE56R1-2212596Always on---H121296.53%100%96.53%0.00%0%-
ZTE23R1-2212596Aligned CDRXAligned every 50ms64H121284%100%84%-12.98%21.2%-
ZTE24R1-2212596Additional active time + aligned CDRXAligned every 50ms64H121288.19%100%88.19%-8.64%21.3%-Note 1
NOTE 1:
additional active time = original DRX On duration
Based on the evaluation results in Table B.2.7-3, the following observations can be made:
  • For FR1, DL and UL joint evaluation, InH, high load, CG 30Mbps traffic at 60fps and 15ms PDB, it is observed from ZTE that:
    • on top of eCDRX, additional active time provides:
      • power saving gain of 21.3% for all UEs
      • capacity gain of -8.64%.
    • eCDRX as the performance reference provides:
      • power saving gain of 21.2% for all UEs
      • capacity gain of -12.98%.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE53R1-2212596Always on---H111190.15%0.00%0%-Note 1
ZTE17R1-2212596Aligned CDRXAligned every 50ms124H111188.36%-1.99%10.4%-Note 1
ZTE18R1-2212596Additional active time + aligned CDRXAligned every 50ms54H111190%-0.17%30%-Note 1,2
vivoR1-2208660Always On---L510100%0%0%-
vivoR1-2208660R17 PDCCH monitoring adaptation16.6784L510100%0%23.36%-Note 3,4
vivoR1-2208660Additional On-Duration16.6744L510100%0%18.73%-Note 5
vivoR1-2208660Always On---H101092.50%0.0%0%-
vivoR1-2208660R17 PDCCH monitoring adaptation16.6784H101092.22%-0.3%19.28%-Note 3,4
vivoR1-2208660Additional On-Duration16.6744H101091.49%-1.1%14.68%-Note 5
NOTE 1:
Jitter range = [-8,8]ms
NOTE 2:
additional active time = original DRX On duration
NOTE 3:
PDCCH skipping is indicated in the DCI that schedules a dummy PDSCH after all the HARQ-ACK processes of transmissions have been completed
NOTE 4:
applying R17 sparse SSSG with PDCCH monitoring every 2 slots when DRX Onduration starts and switch to dense SSSG with PDCCH monitoring every 1 slot after detecting DCI scheduling XR traffic burst
NOTE 5:
additional DRX onduration length is 4ms
Based on the evaluation results in Table B.2.7-4, the following observations can be made:
  • For FR1, DL only, InH, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from ZTE that:
    • with eCDRX, additional active time provides:
      • power saving gain of 30% for all UEs
      • capacity gain of -0.17%.
    • eCDRX as the performance reference provides power:
      • saving gain of 10.4% for all UEs
      • capacity gain of -1.99%.
  • For FR1, DL only, InH, low load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from vivo that:
    • on top of eCDRX, additional active time provides:
      • power saving gain of 18.73% for all UEs
      • capacity gain of 0%
    • eCDRX with R17 PDCCH monitoring adaptation as the performance reference provides:
      • power saving gain of 23.36% for all UEs
      • capacity gain of 0%
  • For FR1, DL only, InH, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from vivo that:
    • with eCDRX, additional active time provides:
      • power saving gain of 14.68% for all UEs
      • capacity gain of -1.1%
    • eCDRX with R17 PDCCH monitoring adaptation as the performance reference provides:
      • power saving gain of 19.28% for all UEs
      • capacity gain of -0.3%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE57R1-2212596Always On---H121296.53%0.00%0%-
ZTE25R1-2212596Aligned CDRXAligned every 50ms64H121284%-12.98%30.9%-
ZTE26R1-2212596Aligned CDRXAligned every 50ms86H121288.89%-7.91%20.6%-
ZTE27R1-2212596Additional active time + aligned CDRXAligned every 50ms64H121288.19%-8.64%32.4%-Note 1
NokiaR1-2209535Always On Baseline---H6690.00 %0.00%0.0%--
Nokia1R1-2209535C-DRX with EAT1680H6651.38 %-42.91%30.33 %-Note 2
Nokia2R1-2209535C-DRX with EAT1660H6649.86 %-44.60%30.40 %-Note 2
Nokia3R1-2209535C-DRX with EAT1640H6651.80 %-42.44%30.43 %-Note 2
Nokia4R1-2209535C-DRX with EAT1620H6651.80 %-42.44%30.43 %-Note 2
NOTE 1:
additional active time = original DRX On duration
NOTE 2:
Extension timer = 1ms
Based on the evaluation results in Table B.2.7-5, the following observations can be made:
  • For FR1, DL only, InH, high load, CG 30Mbps traffic at 60fps and 15ms PDB, it is observed from ZTE that:
    • on top of eCDRX, additional active time provides:
      • power saving gain of 32.4% for all UEs
      • capacity gain of -8.64%.
    • eCDRX as the performance reference provides:
      • mean power saving gain of 25.75% in the range of 20.6% to 30.9% for all UEs
      • mean capacity gain of -10.45% in the range of -12.985 to -7.91%.
  • For FR1, DL only, InH, high load, CG 30Mbps traffic at 60fps and 15ms PDB, it is observed from Nokia that:
    • Extension of active time provides:
      • mean power saving gain of 30.40% for all UEs in the range of 30.33% to 30.43%
      • mean capacity gain of -43.10% for all UEs in the range of -44.60% to -42.44%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE55R1-2212596Always on---H7790.48%0.00%0.00%-Note 1
ZTE21R1-2212596Aligned CDRXAligned every 50ms125H7790%-0.53%8.47%-Note 1
ZTE22R1-2212596Additional active time + aligned CDRXAligned every 50ms65H7788.1%-2.63%20%-Note 1,3
ZTE39R1-2212596Always on---H7790%0.00%0.00%-Note 2
ZTE41R1-2212596Aligned CDRXAligned every 50ms145H7788.10%-2.11%4.60%-Note2
ZTE40R1-2212596Aligned CDRXAligned every 50ms125H7780%-11.11%9.46%-Note2
ZTE42R1-2212596Additional active time + aligned CDRXAligned every 50ms24H7789.48%-0.58%19%-Note2,3
ZTE44R1-2212596PDCCH Skipping (duration = 2ms,4ms)Aligned every 50ms145H7772.62%-19.31%10.84%-Note2
ZTE43R1-2212596PDCCH skipping with dummy grant (duration = 4ms,8ms)Aligned every 50ms145H7780.95%-10.1%13.03%-Note2
NOTE 1:
Jitter range = [-8,8]ms, STD = 2.9ms
NOTE 2:
Jitter range = [-8,8]ms, STD = 5ms
NOTE 3:
additional active time = original DRX On duration
Based on the evaluation results in Table B.2.7-6, the following observations can be made:
  • For FR1, DL only, InH, high load, VR 45Mbps traffic at 60fps and 10ms PDB, it is observed from ZTE that:
  • on top of eCDRX, additional active time provides mean:
    • power saving gain of 19.5% in the range of 19% to 20% for all UEs
    • mean capacity gain of -1.61% in the range of -2.63% to -0.58%.
  • eCDRX performance reference provides:
    • mean power saving gain of 7.51% in the range of 4.60% to 9.46% for all UEs
    • mean capacity gain of -4.58% in the range of -11.11% to -0.53%.
  • eCDRX + PDCCH skipping performance reference provides:
    • mean power saving gain of 11.94% in the range of 10.84% to 13.03% for all UEs
    • mean capacity gain of -14.71% in the range of -19.31% to -10.1%.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
OPPO1R1-2211490Always On---H5590.18%0.0%0.0%0.0%
OPPO3R1-2211490Non-uniform CDRX cycle pattern{17,17,16}102H5588.77%-1.6%18.72%19.43%
OPPO4R1-2211490Non-uniform CDRX cycle pattern with dynamic additional ODT{17,17,16}42H5590.18%0.0%30.86%32.33%Note1
NOTE 1:
another DRX On Duration time indicated by DCI is 4ms
Based on the evaluation results in Table B.2.7-7, the following observations can be made:
  • For FR1, DL only, DU, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from OPPO that:
    • on top of eCDRX, additional active time provides:
      • power saving gain of 30.86% for all UEs
      • capacity gain of 0.0%
    • eCDRX as the performance reference provides:
      • power saving gain of 18.72% for all UEs
      • capacity gain of -1.6%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
ZTE58R1-2212596Always on---H7791.16%0.00%0%-Note 1
ZTE34R1-2212596Aligned CDRXAligned every 50ms145H7787%-4.56%4.86%-Note 1
ZTE35R1-2212596Additional active time + aligned CDRXAligned every 50ms25H7790.48%-0.75%20.53%-Note 1,2
ZTE36R1-2212596PDCCH skipping (duration = 2ms, 4ms)Aligned every 50ms145H7782%-10.05%9.2%-Note 1
ZTE28R1-2212596Always On---H7791.16%0.00%0.0%-
ZTE29R1-2212596Aligned CDRXAligned every 50ms85H7789.8%-1.49%23%-
ZTE30R1-2212596Aligned CDRXAligned every 50ms105H7790.48%-0.75%16%-
ZTE31R1-2212596Additional active time + aligned CDRXAligned every 50ms25H7791.84%0.75%26.24%-Note 2
ZTE32R1-2212596Additional active time + aligned CDRX + PDCCH skipping (duration = 2ms)Aligned every 50ms25H7791.16%0.00%33.5%-
ZTE33R1-2212596PDCCH skipping (duration = 2ms, 4ms)Aligned every 50ms105H7784%-7.9%24%-Note2
ZTE46R1-2212596Always on---H7790%0.00%0%-Note3
ZTE47R1-2212596Aligned CDRXAligned every 50ms145H7785%-5.56%4.50%-Note3
ZTE48R1-2212596Additional active time + aligned CDRXAligned every 50ms24H7784%-6.67%18%-Note3
ZTE49R1-2212596PDCCH Skipping (duration = 2ms,4ms)Aligned every 50ms145H7774%-17.78%9.6%-Note3
ZTE50R1-2212596PDCCH skipping with dummy grant (duration = 4ms,8ms)Aligned every 50ms145H7780%-11.11%12%-Note3
NOTE 1:
Jitter range = [-8,8]ms, STD = 2.9ms
NOTE 2:
additional active time = original DRX On duration
NOTE 3:
Jitter range = [-8,8]ms, STD = 5ms
Based on the evaluation results in Table B.2.7-8, the following observations can be made:
  • For FR1, DL only, DU, high load, VR 45Mbps traffic at 60fps and 10ms PDB, it is observed from ZTE that:
    • with eCDRX, additional active time provides:
      • mean power saving gain of 24.57% in the range of 18% to 33.50% for all UEs
      • mean capacity gain of -1.67% in the range of -6.67% to 0.75%
    • eCDRX performance reference provides:
      • mean power saving gain of 12.09% in the range of 4.50% to 23% for all UEs
      • mean capacity gain of -3.09% in the range of -5.56% to -0.75%
    • eCDRX + PDCCH skipping performance reference provides:
      • mean power saving gain of 13.70% in the range of 9.20% to 24% for all UEs
      • mean capacity gain of -11.71% in the range of -17.78% to -7.90%