Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TR 38.835  Word version:  18.0.1

Top   Top   Up   Prev   Next
1…   4…   5…   6   A   B…   B.1.2   B.1.3   B.1.4   B.1.5   B.1.6   B.1.7   B.1.8   B.1.9   B.1.10   B.2…   B.2.2   B.2.3   B.2.4   B.2.5   B.2.6   B.2.7   B.2.8   B.2.9   B.2.10   B.2.11   B.2.12   B.2.13   B.2.14   B.2.15   B.2.16   B.2.17   B.2.18   C…

 

B.2.4  Two-stage CDRX On Durationp. 66

This clause captures evaluation results for two-stage CDRX On Duration
  • Ericsson evaluated the two-stage DRX solution with multiple inner On Durations within the outer On Duration and compared its performance with that of R17 PDCCH monitoring adaptation.
  • vivo compared R17 PDCCH monitoring adaptation and the two-stage On-Duration by performance evaluations.
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of DL satis­fied UE% of UL satis­fied UE% of DL + UL satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
Ericsson35R1-2210922Always On---H88--90.1%0.0%--Note1
Ericsson38R1-2210922Matched CDRX16.6104H88--85.5%-5.1%7.2%7.1%Note1,2
Ericsson40R1-2210922PDCCH skipping & matched CDRX16.6104H88--84.7%-6.0%7.6%7.6%Note1,2
Ericsson41R1-2210922R17 SSSG switching (sparse SSSG:2 ms on / 2 ms off) & matched CDRX16.6104H88--66.0%-26.7%10.3%10.3%Note1,2
Ericsson42R1-2210922R17 SSSG switching (sparse SSSG:1 ms on / 1 ms off) & matched CDRX16.6104H88--79.8%-11.4%10.7%10.7%Note1,2
Ericsson43R1-2210922R17 SSSG switching (sparse SSSG: 1 ms on / 1 ms off) & PDCCH skipping & matched CDRX16.6104H88--79.9%-11.3%11.3%11.2%Note1,2
Ericsson44R1-2210922Two-stage DRX & matched CDRXouter DRX: 16.6;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4H88--80.2%-11.0%9.1%9.1%Note1,3
Ericsson45R1-2210922Two-stage DRX & matched CDRXouter DRX: 16.6;
inner DRX: 2
outer ODT: 10;
inner ODT: 1
4H88--81.5%-9.5%10.7%10.7%Note1,3
Ericsson46R1-2210922Two-stage DRX & PDCCH skipping & matched CDRXouter DRX: 16.6;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4H88--79.8%-11.4%9.5%9.5%Note1,3
Ericsson47R1-2210922Two-stage DRX & PDCCH skipping & matched CDRXouter DRX: 16.6;
inner DRX: 2
outer ODT: 10;
inner ODT: 1
4H88--80.7%-10.4%11.5%11.5%Note1,3
NOTE 1:
the DL traffic has a second flow for audio with 30ms PDB
NOTE 2:
Matched CDRX cycle has (drx_offset=3, traffic_time_offset=2 ms, drx-LongCycle=16 ms)
NOTE 3:
Outer CDRX cycle has (drx_offset=3, traffic_time_offset=2 ms, drx-LongCycle=16 ms)
Based on the evaluation results in Table B.2.4-1, the following observations can be made:
  • For FR1, DL + UL joint evaluation, DU, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from Ericsson that:
    • two-stage CDRX On Duration provides:
      • mean power saving gain of 10.20% in the range of 9.10% to 11.50% for all UEs
      • mean capacity gain of -10.58% in the range of -11.4% to -9.5%
    • sparse PDDCH monitoring followed by SSSG switching as the performance reference provides:
      • mean power saving gain of 10.77% in the range of 10.30% to 11.30% for all UEs
      • mean capacity gain of -16.47% in the range of -26.7% to -11.3%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
Ericsson1R1-2210922Always On---H8891.7%0.0%0.0%0.0%
Ericsson4R1-2210922Matched CDRX16.6104H8887.2%-4.9%10.5%11.4%Note 1
Ericsson6R1-2210922PDCCH skipping & matched CDRX16.6104H8887.3%-4.8%15.8%16.0%Note 1
Ericsson7R1-2210922R17 SSSG switching (sparse SSSG: 2 ms on / 2 ms off) & matched CDRX16.6104H8853.9%-41.2%15.5%16.0%Note 1
Ericsson8R1-2210922R17 SSSG switching (sparse SSSG: 1 ms on / 1 ms off) & matched CDRX16.6104H8878.4%-14.5%16.4%16.5%Note 1
Ericsson9R1-2210922R17 SSSG switching (sparse SSSG: 1 ms on / 1 ms off) & PDCCH skipping & matched CDRX16.6104H8878.9%-14.0%20.2%20.4%Note 1
Ericsson10R1-2210922Two-stage DRX & matched CDRXouter DRX: 16.6;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4H8879.2%-13.6%14.8%15.1%Note 2
Ericsson11R1-2210922Two-stage DRX & matched CDRXouter DRX: 16.6;
inner DRX: 2
outer ODT: 10;
inner ODT: 1
4H8880.2%-12.5%16.2%16.6%Note 2
Ericsson12R1-2210922Two-stage DRX & PDCCH skipping & matched CDRXouter DRX: 16.6;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4H8878.6%-14.3%19.2%19.4%Note 2
Ericsson13R1-2210922Two-stage DRX & PDCCH skipping & matched CDRXouter DRX: 16.6;
inner DRX: 2
outer ODT: 10;
inner ODT: 1
4H8880.4%-12.3%20.4%20.6%Note 2
Ericsson18R1-2210922Always On---L28100%0.0%0.0%0.0%
Ericsson20R1-2210922Matched CDRX16.6104L28100%0.0%12.8%12.8%Note 1
Ericsson23R1-2210922PDCCH skipping & matched CDRX16.6104L28100%0.0%22.5%22.5%Note 1
Ericsson24R1-2210922R17 SSSG switching (sparse SSSG: 2 ms on / 2 ms off) & matched CDRX16.6104L2882.9%-17.1%18.2%18.2%Note 1
Ericsson25R1-2210922R17 SSSG switching (sparse SSSG: 1 ms on / 1 ms off) & matched CDRX16.6104L28100%0.0%19.2%19.2%Note 1
Ericsson26R1-2210922R17 SSSG switching (sparse SSSG: 1 ms on / 1 ms off) & PDCCH skipping & matched CDRX16.6104L28100%0.0%26.6%26.6%Note 1
Ericsson27R1-2210922Two-stage DRX & matched CDRXouter DRX: 16.6;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4L28100%0.0%16.7%16.7%Note 2
Ericsson28R1-2210922Two-stage DRX & matched CDRXouter DRX: 16.6;
inner DRX: 2
outer ODT: 10;
inner ODT: 1
4L28100%0.0%19.0%19.0%Note 2
Ericsson29R1-2210922Two-stage DRX & PDCCH skipping & matched CDRXouter DRX: 16.6;
inner DRX: 4
outer ODT: 10;
inner ODT: 2
4L28100%0.0%25.9%25.9%Note 2
Ericsson30R1-2210922Two-stage DRX & PDCCH skipping & matched CDRXouter DRX: 16.6;
inner DRX: 2
outer ODT: 10;
inner ODT: 1
4L28100%0.0%27.0%27.0%Note 2
NOTE 1:
Matched CDRX cycle has (drx_offset=3, traffic_time_offset=2 ms, drx-LongCycle=16 ms)
NOTE 2:
Outer CDRX cycle has (drx_offset=3, traffic_time_offset=2 ms, drx-LongCycle=16 ms)
Based on the evaluation results in Table B.2.4-2, the following observations can be made:
  • For FR1, DL only, DU, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from Ericsson that:
    • two-stage CDRX On Duration provides:
      • mean power saving gain of 17.65% in the range of 4.80% to 20.40% for all UEs
      • mean capacity gain of -13.18% in the range of -14.30% to -12.30%
    • sparse PDDCH monitoring followed by SSSG switching as the performance reference provides:
      • mean power saving gain of 17.37% in the range of 15.50% to 20.20% for all UEs
      • mean capacity gain of -23.23% in the range of -41.20% to -14.00%
  • For FR1, DL only, DU, low load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from Ericsson that:
    • two-stage CDRX On Duration provides:
      • mean power saving gain of 22.15% in the range of 6.70% to 27.00% for all UEs
      • mean capacity gain of 0%
    • sparse PDDCH monitoring followed by SSSG switching as the performance reference provides:
      • mean power saving gain of 21.33% in the range of 18.20% to 26.60% for all UEs
      • mean capacity gain of -5.70% in the range of 0.00% to -17.10%
sourcedata row indexTdoc sourcePower saving schemeCDRX cycle (ms)ODT (ms)IAT (ms)Load H/L#UE /cellfloor (Capa­city)% of satis­fied UECapa­city gain (%)Mean PSG of all UEs (%)Mean PSG of satis­fied UEs (%)Addi­tional Assump­tions
vivoR1-2211024Always On---L510100%0.0%0.0%-
vivoR1-2211024R17 PDCCH monitoring adaptation16.6784L510100%0.0%23.36%-Note1,2
vivoR1-2211024R17 PDCCH monitoring adaptation16.6784L510100%0.0%25.39%-Note1,3
vivoR1-2211024Two-stage CDRXOuter CDRX: 16.67
Inner CDRX: 4
Outer CDRX: 10
Inner CDRX: 2
Outer CDRX: 4
Inner CDRX: 4
L510100%0.0%21.52%-Note4
vivoR1-2211024Always On---H101092.50%0.0%0.0%-
vivoR1-2211024R17 PDCCH monitoring adaptation16.6784H101092.22%-0.3%19.28%-Note1,2
vivoR1-2211024R17 PDCCH monitoring adaptation16.6784H101088.52%-4.3%21.84%-Note1,3
vivoR1-2211024Two-stage CDRXOuter CDRX: 16.67
Inner CDRX: 4
Outer CDRX: 10
Inner CDRX: 2
Outer CDRX: 4
Inner CDRX: 4
H101086.89%-6.1%16.36%-Note4
NOTE 1:
PDCCH skipping is indicated in the DCI that schedules a dummy PDSCH after all the HARQ-ACK processes of transmissions have been completed
NOTE 2:
applying R17 sparse SSSG with PDCCH monitoring every 2 slots when DRX Onduration starts and switch to dense SSSG with PDCCH monitoring every 1 slot after detecting DCI scheduling XR traffic burst
NOTE 3:
applying R17 sparse SSSG with PDCCH monitoring every 4 slots when DRX Onduration starts and switch to dense SSSG with PDCCH monitoring every 1 slot after detecting DCI scheduling XR traffic burst
NOTE 4:
4ms CDRX cycle and 2ms ODT for inner CDRX
Based on the evaluation results in Table B.2.4-3, the following observations can be made:
  • For FR1, DL only, InH, high load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from vivo that:
    • two-stage CDRX On Duration provides:
      • power saving gain of 16.36% for all UEs
      • capacity gain of -6.1%
    • sparse PDDCH monitoring followed by SSSG switching as the performance reference provides:
      • mean power saving gain of 20.56% in the range of 19.28% to 21.84% for all UEs
      • mean capacity gain of -2.3% in the range of -4.3% to -0.3%
  • For FR1, DL only, InH, low load, VR 30Mbps traffic at 60fps and 10ms PDB, it is observed from vivo that:
    • two-stage CDRX On Duration provides:
      • power saving gain of 21.52% for all UEs
      • mean capacity gain of 0.0%
    • sparse PDDCH monitoring followed by SSSG switching as the performance reference provides:
      • mean power saving gain of 24.38% in the range of 23.36% to 25.39% for all UEs
      • mean capacity gain of 0.0%
Up

Up   Top   ToC