The set command is used to close or open the UE test loop mode E according to UE test loop procedures as defined in
TS 36.509 clause 5.4.2, clause 5.4.4c and clause 5.4.5 for V2X over E-UTRA PC5, and in 3GPP TS 38.509 [178] clause 5.3.2, clause 5.3.3 and clause 5.3.4.3. The AT command is only applicable when test mode is activated, see clause
15.2. The
<status> indicates whether the UE test loop mode E is closed or opened. If
<status>=0, the parameters
<direction>,
<format>,
<length> and
<monitor_list> are as required provided to configure UE test loop mode E.
The UE test loop mode E provides means for either transmitting or receiving of V2X communication packets, and the
<direction> indicates the direction of communication under test. For communication receive operation,
<direction>=0 and the UE test loop mode E provides counting of successfully received STCH PDCP SDUs for V2X over E-UTRA PC5 or STCH SDAP SDUs for V2X over NR PC5, PSCCH transport blocks and PSSCH transport blocks. The parameters
<format>,
<length> and
<monitor_list> must be provided. For communication transmit operation,
<direction>=1 and the UE test loop mode E provides trigger for transmission of IP packets for V2X communication message on STCH. The parameters
<format>,
<length> and
<monitor_list> are not used and ignored if received. The parameter
<sl_mimo> indicates the number of spatial layer(s) used for NR PSSCH transmission for UE which supports SL MIMO, and is not used and ignored if UE doesn't support SL MIMO. All parameters are discarded when
<status>=1 or when the UE test mode is deactivated.
The read command returns the current settings.
The test command returns values supported as compound values.
<status>
integer type. Indicates the state of UE test loop E.
0
closed
1
opened
<direction>
integer type. Indicates the direction of communication under test.
0
communication receive
1
communication transmit
<format>
integer type. Indicates the format of the
<monitor_list> parameter.
1
binary format
<length>
integer type. Indicates the number of 24 bit Destination Layer-2 IDs in the parameter
<monitor_list>.
<monitor_list>
string of octets. This parameter contains all 24 bit Destination Layer-2 IDs to monitor for V2X communication. The type of string is in the format as specified by
<format>. The number of 24 bit Destination Layer-2 IDs is given by
<length>. The parameter shall not be subject to conventional character conversion as per +CSCS.
<sl_mimo>
integer type. Indicates the number of spatial layer(s) used for NR PSSCH transmission when
<direction>=1.
0
1 layer
1
2 layers