Information | Source | Description |
---|---|---|
UL/DL packet drop rate GTP-U | OAM (see NOTE 2) | UL/DL packet drop rate measurement on GTP path on N3. |
UL/DL packet delay GTP | OAM (see NOTE 2) | UL/DL packet delay measurement round trip on GTP path on N3. |
E2E UL/DL packet delay (see NOTE 3) | UPF | End-to-End (between UE and UPF) packet delay measurements between the UE and the UPF. |
UL/DL packet drop/loss rate of RAN part | OAM (see NOTE 2) | UL/DL packet drop/loss rate measurement of RAN part. |
NOTE 1:
The information in this Table is provided both as the base to compare with the redundant transmission performance as well as when redundant transmission is enabled.
NOTE 2:
Refer to clause 5.1 of TS 28.552 for the performance measurement in NG-RAN and clause 5.4 of TS 28.552 for the performance measurement in UPF. In addition, Annex A of TS 28.552 describes various performance measurements.
NOTE 3:
Refer to clause 5.33.3 of TS 23.501 for the packet delay measurement in the UPF.
|
Information | Source | Description |
---|---|---|
DNN | SMF | Data Network Name associated for URLLC service. |
UP with redundant transmission | SMF | Redundant transmission is setup or terminated. |
Information | Source | Description |
---|---|---|
E2ELatencyIssueType | MDAF | Indication the type of the E2E latency issue. The allowed value is one of the enumerated values: RAN latency issue, CN latency issue. |
AffectedObjects | MDAF | The managed object instances of subnetwork, managed elements or network slices where the latency issue happens. |
Information | Description |
---|---|
UE group ID or UE ID, any UE | Identifies the UE(s) for which the statistic applies by a list of SUPIs, or a group of UEs by a list of Internal-Group-Ids. |
DNN | Data Network Name associated for URLLC service. |
Spatial validity | Area where the Redundant Transmission Experience statistics applies. If Area of Interest information was provided in the request or subscription, spatial validity should be the requested Area of Interest. |
Time slot entry (1..max) | List of time slots during the Analytics target period. |
> Time slot start | Time slot start within the Analytics target period. |
> Duration | Duration of the time slot. If a Temporal granularity size was provided in the request or subscription, the Duration is greater than or equal to the Temporal granularity size. |
> Observed Redundant Transmission Experience | Observed Redundant Transmission Experience related information during the Analytics target period. |
>> UL/DL packet drop rate GTP-U (NOTE 2) | Observed UL/DL packet drop rate on GTP-U path on N3 (average, variance). |
>> UL/DL packet delay GTP-U (NOTE 2) | Observed UL/DL packet delay round trip on GTP-U path on N3 (average, variance). |
>> E2E UL/DL packet delay (NOTE 2) | Observed End-to-End (between UE and UPF) UL/DL packet delay (average, variance). |
>> E2E UL/DL packet loss rate (NOTE 2) (NOTE 3) | Observed End-to-End (between UE and UPF) UL/DL packet loss (average, variance) |
> Redundant Transmission Status | Redundant Transmission Status, i.e. redundant transmission was activated or not activated for the time slot entry. |
> Ratio | Percentage on which UE, any UE, or UE group experience the packet drop rate and packet delay. |
NOTE 1:
The Observed Redundant Transmission Experience can be further derived by SMF from the observed UL/DL packet drop rate GTP-U and UL/DL packet delay GTP-U.
NOTE 2:
This information element is an analytics subset that can be used in "list of analytics subsets that are requested" and only applicable when Target of Analytics Reporting is for a single UE.
NOTE 3:
The NWDAF outputs the analytics on E2E UL/DL packet loss rate based on the input UL/DL packet drop rate on N3 and UL/DL packet drop/loss rate of RAN part.
|
Information | Description |
---|---|
UE group ID or UE ID, any UE | Identifies the UE(s) for which the prediction applies by a list of SUPIs, or a group of UEs by a list of Internal-Group-Ids. |
DNN | Data Network Name associated for URLLC service. |
Spatial validity | Area where the estimated Redundant Transmission Experience predictions applies. If Area of Interest information was provided in the request or subscription, spatial validity should be the requested Area of Interest. |
Time slot entry (1..max) | List of predicted time slots. |
>Time slot start | Time slot start time within the Analytics target period. |
> Duration | Duration of the time slot. |
> Predicted Redundant Transmission Experience | Predicted Redundant Transmission Experience related information during the Analytics target period. |
>> UL/DL packet drop rate GTP-U (NOTE 2) | Predicted UL/DL packet drop rate on GTP-U path on N3 (average, variance). |
>> UL/DL packet delay GTP-U (NOTE 2) | Predicted UL/DL packet delay round trip on GTP-U path on N3 (average, variance). |
>> E2E UL/DL packet delay | Predicted End-to-End (between UE and UPF) UL/DL packet delay (average, variance). |
>> E2E UL/DL packet loss rate (NOTE 4) | Predicted End-to-End (between UE and UPF) UL/DL packet loss rate (average, variance). |
>Redundant Transmission Status (NOTE 3) | Redundant Transmission Status, i.e., redundant transmission is activated or not activated for the time slot entry. |
> Ratio | Percentage on which the UE, any UE, or UE group may efficiently use the PDU session with redundant transmission. |
> Confidence | Confidence of this prediction. |
NOTE 1:
The Predicted Redundant Transmission Experience can be further derived by the SMF from the predicted UL/DL packet drop rate GTP-U and UL/DL packet delay GTP-U and based on which the SMF can decide to start redundant transmission or not.
NOTE 2:
This information element is an analytics subset that can be used in "list of analytics subsets that are requested" and only applicable when Target of Analytics Reporting is for a single UE.
NOTE 3:
The list of predicted time slots and predicted redundant transmission experience is provided to the consumer when both the redundant transmission status is activated and not activated.
NOTE 4:
The NWDAF outputs the prediction on E2E UL/DL packet loss rate based on the input UL/DL packet drop rate on N3 and UL/DL packet drop/loss rate of RAN part.
|