Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 23.433  Word version:  19.3.0

Top   Top   Up   Prev   Next
0…   4…   7…   8…   9.2…   9.2.2.3…   9.2.3…   9.2.4…   9.3…   9.3.2.2…   9.3.3…   9.3.4…   9.4…   9.5…   9.5.3…   9.5.4…   9.6…   9.7…   9.7.3…   9.7.4…   9.8…   9.9…   9.9.3…   9.10…   9.10.3…   9.11…   9.11.3…   9.12…   A…   C   D…

 

4  Overviewp. 13

4.1  Generalp. 13

This clause gives a functionality overview for SEALDD service.

4.2  Application signalling and data transmissionp. 13

This SEALDD functionality provides a mechanism for application signalling data transmission and application media data transmission between VAL client(s) and VAL server(s). The SEALDD enabled regular connection management procedures (e.g. connection establishment, connection deletion) are specified in clause 9.2. For supporting URLLC feature, the SEALDD layer can establish E2E redundant transmission with packet duplication and elimination, as specified in clause 9.3.
Up

4.3  Transmission quality measurement and transmission optimizationp. 13

The transmission quality measurement procedure specified in clause 9.7, supports the E2E transmission quality measurement between SEALDD client and SEALDD server, and exposes the transmission reports to VAL servers and other consumers (e.g. SEALDD server, NSCE server, etc). Based on the SEALDD enabled E2E transmission measurement result, the SEALDD layer can provide transmission optimization scheme (e.g. triggering redundant transmission, switching another SEALDD server) to improve transmission quality by interacting with 5GC. The transmission optimization procedures are specified in clause 9.9.
Up

4.4  Data transmission rate controlp. 13

The SEALDD layer can provide the differentiated data delivery service with different bandwidth/transmission rate experience for VAL users, considering the network conditions (e.g. QoS monitoring, ECN marking for L4S report), which is described in clause 9.8.

4.5  Service continuity supportp. 13

This functionality is provided to support service continuity due to UE mobility or load balance. The SEALDD layer can maintain the transport layer connection by interacting SEALDD context, and requesting 5GC to perform seamless data transmission (e.g. IP replacement procedure, simultaneous connectivity). The service continuity support procedures are specified in clause 9.6.

4.6  Data storagep. 13

The SEALDD server supports the data storage and storage management for VAL server, SEALDD client and other SEALDD servers, etc, the corresponding procedure is specified in clause 9.5.

5  Business relationshipsp. 13

5.1  Generalp. 13

The clause specifies the business relationships between the various stakeholders like VAL user, VAL service provider, SEALDD provider and PLMN operator.

5.2  Business relationship option-Ap. 14

Figure 5.2-1 shows the business relationship option-A that exist and that are needed to support a single VAL user.
Reproduction of 3GPP TS 23.433, Fig. 5.2-1: Business relationship option-A for VAL services
Up
The VAL user belongs to a VAL service provider based on a VAL service agreement between the VAL user and the VAL service provider. The VAL service provider can have VAL service agreements with several VAL users. The VAL user can have VAL service agreements with several VAL service providers.
The VAL service provider and the PLMN operator can be part of the same organization, in which case the business relationship between the two is internal to a single organization.
The VAL service provider can have SEAL provider arrangements with multiple SEAL providers and the SEAL provider can have PLMN operator service arrangements with multiple PLMN operators. The SEAL provider and the VAL service provider or the PLMN operator can be part of the same organization, in which case the business relationship between the two is internal to a single organization.
The PLMN operator can have PLMN operator service arrangements with multiple VAL service providers and the VAL service provider can have PLMN operator service arrangements with multiple PLMN operators. As part of the PLMN operator service arrangement between the VAL service provider and the PLMN operator, PLMN subscription arrangements can be provided which allows the VAL UEs to register with PLMN operator network.
Up

5.3  Business relationship option-Bp. 14

Figure 5.3-1 shows the business relationship option-B that exist and that are needed to support a single VAL user.
Reproduction of 3GPP TS 23.433, Fig. 5.3-1: Business relationship option-B for VAL services
Up
The VAL user belongs to a VAL service provider based on a VAL service agreement between the VAL user and the VAL service provider. The VAL service provider can have VAL service agreements with several VAL users. The VAL user can have VAL service agreements with several VAL service providers.
The VAL user can have PLMN operator service arrangements with the PLMN operator. The PLMN operator service arrangement includes the UE subscription arrangement which allows the VAL UEs to register with operator network.
The VAL service provider can have SEALDD provider arrangements with multiple SEALDD providers and the SEALDD provider can have SEALDD provider arrangements with multiple VAL service providers.
The PLMN operator can have PLMN operator service arrangements with multiple SEALDD service providers and the SEALDD service provider can have PLMN operator service arrangements with multiple PLMN operators. The SEALDD service provider and the PLMN operator can be part of the same organization, in which case the business relationship between the two is internal to a single organization.
Up

6  Architectural requirementsp. 15

6.1  Generalp. 15

6.1.1  Descriptionp. 15

The general architecture requirements specified in clause 4.1 of TS 23.434 are applicable for SEALDD service. This clause specifies the general requirements for SEALDD service.

6.1.2  Requirementsp. 15

[AR-6.1.2-a]
The SEALDD service shall provide a discovery mechanism to support data delivery between VAL client(s) and VAL servers(s) considering different deployments of VAL server(s) (e.g. cloud or edge).

6.2  Data transmission requirementsp. 16

6.2.1  Descriptionp. 16

This clause specifies the data transmission requirements for SEALDD service.

6.2.2  Requirementsp. 16

[AR-6.2.2-a]
The SEALDD service shall provide a mechanism for application signalling data transmission and application media data transmission between VAL client(s) and VAL server(s).
[AR-6.2.2-b]
The SEALDD service shall provide a mechanism to support the data transmission quality requirement configurations and measurements for the application data transmission between VAL client(s) and VAL server(s).
[AR-6.2.2-c]
The SEALDD service shall provide a mechanism for application data transmission between VAL client(s) and VAL server(s) with guaranteed quality.
[AR-6.2.2-d]
The SEALDD service shall provide a mechanism for application data packaging and un-packaging to support the data transmission between VAL client(s) and VAL server(s).
[AR-6.2.2-e]
The SEALDD service shall provide a mechanism for E2E redundant data transmission between VAL client and VAL server.
[AR-6.2.2-f]
The SEALDD service shall provide a mechanism to support the packet/data duplication, elimination and error recovery between VAL client and VAL server.
Up

6.3  Data storage requirementsp. 16

6.3.1  Descriptionp. 16

This clause specifies the data storage requirements for SEALDD service.

6.3.2  Requirementsp. 16

[AR-6.3.2-a]
The SEALDD service shall provide a mechanism for data storage supporting the CRUD operations.
[AR-6.3.2-b]
The SEALDD service shall provide a mechanism to support the data storage status management.

6.4  SEALDD server discovery and selection requirementsp. 16

6.4.1  Descriptionp. 16

This clause specifies the SEALDD server discovery and selection requirements for SEALDD service.

6.4.2  Requirementsp. 16

[AR-6.4.2-a]
The SEALDD service shall provide a mechanism for supporting the SEALDD server discovery and selection for VAL server.
[AR-6.4.2-b]
The SEALDD service shall provide a mechanism to provide the information of SEALDD server to VAL/SEALDD client.

6.5  MSGin5G message transfer requirementsp. 17

6.5.1  Descriptionp. 17

This clause specifies the MSGin5G message transfer requirements for SEALDD service.

6.5.2  Requirementsp. 17

[AR-6.5.2-a]
The SEALDD service shall provide a mechanism to support the SEALDD traffic transmission using MSGin5G message.

6.6  Data transmission bandwidth control requirementsp. 17

6.6.1  Descriptionp. 17

This clause specifies the data transmission bandwidth control requirements for SEALDD service.

6.6.2  Requirementsp. 17

[AR-6.6.2-a]
The SEALDD service shall provide a mechanism to support the transmission bandwidth control for VAL application.

Up   Top   ToC