The sensitivity/frequency characteristics shall be as follows:
The sending sensitivity frequency response, measured either from the mouth reference point (MRP) to the digital interface or from the MRP to the SS audio output (digital output of the reference speech decoder of the SS), shall be within a mask, which can be drawn between the points given in
Table 9. The mask is drawn with straight lines between the breaking points in
Table 1 on a logarithmic (frequency) - linear (dB sensitivity) scale.
Compliance shall be checked by the relevant test described in
TS 26.132.
The sensitivity/frequency characteristics shall be as follows:
The receiving sensitivity frequency response, measured either from the digital interface to the DRP with diffuse-field correction or from the SS audio input (analogue or digital input of the reference speech encoder of the SS) to the DRP with diffuse-field correction, shall be within a mask, which can be drawn with straight lines between the breaking points in
Table 10 on a logarithmic (frequency) - linear (dB sensitivity) scale.
Compliance shall be checked by the relevant test described in
TS 26.132.