6. Definitions
FC-MGMT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, Counter64, transmission FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC ifIndex FROM IF-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB; fcMgmtMIB MODULE-IDENTITY LAST-UPDATED "200504260000Z" -- 26 April 2005 ORGANIZATION "IETF IPS (IP-Storage) Working Group" CONTACT-INFO " Keith McCloghrie Cisco Systems, Inc. Tel: +1 408 526-5260 E-mail: kzm@cisco.com Postal: 170 West Tasman Drive San Jose, CA USA 95134 " DESCRIPTION "This module defines management information specific to Fibre Channel-attached devices.
Copyright (C) The Internet Society (2005). This version of this MIB module is part of RFC 4044; see the RFC itself for full legal notices." REVISION "200504260000Z" -- 26 April 2005 DESCRIPTION "Initial version of the Fibre Channel Mgmt MIB module." ::= { transmission 56 } fcmgmtObjects OBJECT IDENTIFIER ::= { fcMgmtMIB 1 } fcmgmtNotifications OBJECT IDENTIFIER ::= { fcMgmtMIB 2 } fcmgmtNotifPrefix OBJECT IDENTIFIER ::= { fcmgmtNotifications 0 } fcmgmtConformance OBJECT IDENTIFIER ::= { fcMgmtMIB 3 } --******************************** -- Textual Conventions -- FcNameIdOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The World Wide Name (WWN) associated with a Fibre Channel (FC) entity. WWNs were initially defined as 64-bits in length. The latest definition (for future use) is 128-bits long. The zero-length string value is used in circumstances in which the WWN is unassigned/unknown." SYNTAX OCTET STRING (SIZE(0 | 8 | 16)) FcAddressIdOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A Fibre Channel Address ID, a 24-bit value unique within the address space of a Fabric. The zero-length string value is used in circumstances in which the WWN is unassigned/unknown." SYNTAX OCTET STRING (SIZE(0 | 3)) FcDomainIdOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The Domain Id (of an FC switch), or zero if the no Domain Id has been assigned." SYNTAX Integer32 (0..239)
FcPortType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The type of a Fibre Channel port, as indicated by the use of the appropriate value assigned by IANA." REFERENCE "The IANA-maintained registry for Fibre Channel port types (http://www.iana.org/)." SYNTAX Unsigned32 FcClasses ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A set of Fibre Channel classes of service." REFERENCE "Classes of service are described in FC-FS Section 13." SYNTAX BITS { classF(0), class1(1), class2(2), class3(3), class4(4), class5(5), class6(6) } FcBbCredit ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The buffer-to-buffer credit of an FC port." SYNTAX Integer32 (0..32767) FcBbCreditModel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The buffer-to-buffer credit model of an Fx_Port." SYNTAX INTEGER { regular(1), alternate (2) } FcDataFieldSize ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The Receive Data Field Size associated with an FC port." SYNTAX Integer32 (128..2112)
FcUnitFunctions ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A set of functions that a Fibre Channel Interconnect Element or Platform might perform. A value with no bits set indicates the function(s) are unknown. The individual bits have the following meanings: other - none of the following. hub - a device that interconnects L_Ports, but does not operate as an FL_Port. switch - a fabric element conforming to the Fibre Channel switch fabric set of standards (e.g., [FC-SW-3]). bridge - a device that encapsulates Fibre Channel frames within another protocol (e.g., [FC-BB], FC-BB-2). gateway - a device that converts an FC-4 to another protocol (e.g., FCP to iSCSI). host - a computer system that provides end users with services such as computation and storage access. storageSubsys - an integrated collection of storage controllers, storage devices, and necessary software that provides storage services to one or more hosts. storageAccessDev - a device that provides storage management and access for heterogeneous hosts and heterogeneous devices (e.g., medium changer). nas - a device that connects to a network and provides file access services. wdmux - a device that modulates/demodulates each of several data streams (e.g., Fibre Channel protocol data streams) onto/from a different part of the light spectrum in an optical fiber. storageDevice - a disk/tape/etc. device (without the controller and/or software required for it to be a 'storageSubsys')." SYNTAX BITS { other(0), -- none of the following hub(1), switch(2),
bridge(3), gateway(4), host(5), storageSubsys(6), storageAccessDev(7), nas(8), wdmux(9), storageDevice(10) } --******************************** -- MIB object definitions -- fcmInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the local Fibre Channel management instances." ::= { fcmgmtObjects 1 } fcmInstanceEntry OBJECT-TYPE SYNTAX FcmInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of attributes for a particular local Fibre Channel management instance." INDEX { fcmInstanceIndex } ::= { fcmInstanceTable 1 } FcmInstanceEntry ::= SEQUENCE { fcmInstanceIndex Unsigned32, fcmInstanceWwn FcNameIdOrZero, fcmInstanceFunctions FcUnitFunctions, fcmInstancePhysicalIndex Integer32, fcmInstanceSoftwareIndex Integer32, fcmInstanceStatus INTEGER, fcmInstanceTextName SnmpAdminString, fcmInstanceDescr SnmpAdminString, fcmInstanceFabricId FcNameIdOrZero }
fcmInstanceIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer value that uniquely identifies this instance amongst all local Fibre Channel management instances. It is mandatory to keep this value constant between restarts of the agent, and to make every possible effort to keep it constant across restarts (but note, it is unrealistic to expect it to remain constant across all re-configurations of the local system, e.g., across the replacement of all non- volatile storage)." ::= { fcmInstanceEntry 1 } fcmInstanceWwn OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "If the instance has one (or more) WWN(s), then this object contains that (or one of those) WWN(s). If the instance does not have a WWN associated with it, then this object contains the zero-length string." ::= { fcmInstanceEntry 2 } fcmInstanceFunctions OBJECT-TYPE SYNTAX FcUnitFunctions MAX-ACCESS read-only STATUS current DESCRIPTION "One (or more) Fibre Channel unit functions being performed by this instance." ::= { fcmInstanceEntry 3 } fcmInstancePhysicalIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "If this management instance corresponds to a physical component (or to a hierarchy of physical components) identified by the Entity-MIB, then this object's value is the value of the entPhysicalIndex of that component (or of the component at the root of that hierarchy). If there is
no correspondence to a physical component (or no component that has an entPhysicalIndex value), then the value of this object is zero." REFERENCE "entPhysicalIndex is defined in the Entity MIB, RFC 2737." ::= { fcmInstanceEntry 4 } fcmInstanceSoftwareIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "If this management instance corresponds to an installed software module identified in the Host Resources MIB, then this object's value is the value of the hrSWInstalledIndex of that module. If there is no correspondence to an installed software module (or no module that has a hrSWInstalledIndex value), then the value of this object is zero." REFERENCE "hrSWInstalledIndex is defined in the Host Resources MIB, RFC 2790" ::= { fcmInstanceEntry 5 } fcmInstanceStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), ok(2), -- able to operate correctly warning(3), -- needs attention failed(4) -- something has failed } MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of the Fibre Channel entity/entities managed by this management instance. The value should reflect the most serious status of such entities." ::= { fcmInstanceEntry 6 } fcmInstanceTextName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..79)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual name for this management instance and the Fibre Channel entity/entities that it is managing." ::= { fcmInstanceEntry 7 }
fcmInstanceDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "A textual description of this management instance and the Fibre Channel entity/entities that it is managing." ::= { fcmInstanceEntry 8 } fcmInstanceFabricId OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The globally unique Fabric Identifier that identifies the fabric to which the Fibre Channel entity/entities managed by this management instance are connected, or, of which they are a part. This is typically the Node WWN of the principal switch of a Fibre Channel fabric. The zero-length string indicates that the fabric identifier is unknown (or not applicable). In the event that the Fibre Channel entity/entities managed by this management instance is/are connected to multiple fabrics, then this object records the first (known) one." ::= { fcmInstanceEntry 9 } --******************************** -- The Fibre Channel Switch Table -- fcmSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information about Fibre Channel switches that are managed by Fibre Channel management instances. Each Fibre Channel management instance can manage one or more Fibre Channel switches." ::= { fcmgmtObjects 2 } fcmSwitchEntry OBJECT-TYPE SYNTAX FcmSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular Fibre Channel switch that is
managed by the management instance given by fcmInstanceIndex." INDEX { fcmInstanceIndex, fcmSwitchIndex } ::= { fcmSwitchTable 1 } FcmSwitchEntry ::= SEQUENCE { fcmSwitchIndex Unsigned32, fcmSwitchDomainId FcDomainIdOrZero, fcmSwitchPrincipal TruthValue, fcmSwitchWWN FcNameIdOrZero } fcmSwitchIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer that uniquely identifies a Fibre Channel switch amongst those managed by one Fibre Channel management instance. It is mandatory to keep this value constant between restarts of the agent, and to make every possible effort to keep it constant across restarts." ::= { fcmSwitchEntry 1 } fcmSwitchDomainId OBJECT-TYPE SYNTAX FcDomainIdOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "The Domain Id of this switch. A value of zero indicates that a switch has not (yet) been assigned a Domain Id." ::= { fcmSwitchEntry 2 } fcmSwitchPrincipal OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this switch is the principal switch within its fabric." ::= { fcmSwitchEntry 3 }
fcmSwitchWWN OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The World Wide Name of this switch." ::= { fcmSwitchEntry 4 } --******************************** -- The Fibre Channel Port Table -- fcmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about Fibre Channel ports. Each Fibre Channel port is represented by one entry in the IF-MIB's ifTable." REFERENCE "RFC 2863, The Interfaces Group MIB, June 2000." ::= { fcmgmtObjects 3 } fcmPortEntry OBJECT-TYPE SYNTAX FcmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about a specific port." INDEX { ifIndex } ::= { fcmPortTable 1 } FcmPortEntry ::= SEQUENCE { fcmPortInstanceIndex Unsigned32, fcmPortWwn FcNameIdOrZero, fcmPortNodeWwn FcNameIdOrZero, fcmPortAdminType FcPortType, fcmPortOperType FcPortType, fcmPortFcCapClass FcClasses, fcmPortFcOperClass FcClasses, fcmPortTransmitterType INTEGER, fcmPortConnectorType INTEGER, fcmPortSerialNumber SnmpAdminString, fcmPortPhysicalNumber Unsigned32, fcmPortAdminSpeed INTEGER, fcmPortCapProtocols BITS, fcmPortOperProtocols BITS
} fcmPortInstanceIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of fcmInstanceIndex by which the Fibre Channel management instance, which manages this port, is identified in the fcmInstanceTable." ::= { fcmPortEntry 1 } fcmPortWwn OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The World Wide Name of the port, or the zero-length string if the port does not have a WWN." ::= { fcmPortEntry 2 } fcmPortNodeWwn OBJECT-TYPE SYNTAX FcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The World Wide Name of the Node that contains this port, or the zero-length string if the port does not have a node WWN." ::= { fcmPortEntry 3 } fcmPortAdminType OBJECT-TYPE SYNTAX FcPortType MAX-ACCESS read-write STATUS current DESCRIPTION "The administratively desired type of this port." ::= { fcmPortEntry 4 } fcmPortOperType OBJECT-TYPE SYNTAX FcPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational type of this port." ::= { fcmPortEntry 5 }
fcmPortFcCapClass OBJECT-TYPE SYNTAX FcClasses MAX-ACCESS read-only STATUS current DESCRIPTION "The classes of service capability of this port." ::= { fcmPortEntry 6 } fcmPortFcOperClass OBJECT-TYPE SYNTAX FcClasses MAX-ACCESS read-only STATUS current DESCRIPTION "The classes of service that are currently operational on this port. For an FL_Port, this is the union of the classes being supported across all attached NL_Ports." ::= { fcmPortEntry 7 } fcmPortTransmitterType OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), shortwave850nm(3), longwave1550nm(4), longwave1310nm(5), electrical(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The technology of the port transceiver." REFERENCE "FC-GS-3, section 6.1.2.2.3" ::= { fcmPortEntry 8 } fcmPortConnectorType OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), gbic(3), embedded(4), glm(5), gbicSerialId(6), gbicNoSerialId(7), sfpSerialId(8), sfpNoSerialId(9) } MAX-ACCESS read-only
STATUS current DESCRIPTION "The module type of the port connector. This object refers to the hardware implementation of the port. It will be 'embedded' if the hardware equivalent to Gigabit interface card (GBIC) is part of the line card and is unremovable. It will be 'glm' if it's a gigabit link module (GLM). It will be 'gbicSerialId' if the GBIC serial id can be read, else it will be 'gbicNoSerialId'. It will be 'sfpSerialId' if the small form factor (SFP) pluggable GBICs serial id can be read, else it will be 'sfpNoSerialId'." REFERENCE "FC-GS-3, section 6.1.2.2.4" ::= { fcmPortEntry 9 } fcmPortSerialNumber OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number associated with the port (e.g., for a GBIC). If not applicable, the object's value is a zero- length string." REFERENCE "FC-GS-3, section 6.1.2.2.4" ::= { fcmPortEntry 10 } fcmPortPhysicalNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port's 'Physical Port Number' as defined by GS-3." REFERENCE "FC-GS-3, section 6.1.2.2.5" ::= { fcmPortEntry 11 } fcmPortAdminSpeed OBJECT-TYPE SYNTAX INTEGER { auto(1), eighthGbs(2), -- 125Mbs quarterGbs(3), -- 250Mbs halfGbs(4), -- 500Mbs oneGbs(5), -- 1Gbs twoGbs(6), -- 2Gbs fourGbs(7), -- 4Gbs tenGbs(8) -- 10Gbs
} MAX-ACCESS read-write STATUS current DESCRIPTION "The speed of the interface: 'auto' - auto-negotiation 'tenGbs' - 10Gbs 'fourGbs' - 4Gbs 'twoGbs' - 2Gbs 'oneGbs' - 1Gbs 'halfGbs' - 500Mbs 'quarterGbs' - 250Mbs 'eighthGbs' - 125Mbs" ::= { fcmPortEntry 12 } fcmPortCapProtocols OBJECT-TYPE SYNTAX BITS { unknown(0), loop(1), fabric(2), scsi(3), tcpIp(4), vi(5), ficon(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit mask specifying the higher level protocols that are capable of running over this port. Note that for generic Fx_Ports, E_Ports, and B_Ports, this object will indicate all protocols." ::= { fcmPortEntry 13 } fcmPortOperProtocols OBJECT-TYPE SYNTAX BITS { unknown(0), loop(1), fabric(2), scsi(3), tcpIp(4), vi(5), ficon(6) } MAX-ACCESS read-only STATUS current DESCRIPTION
"A bit mask specifying the higher level protocols that are currently operational on this port. For Fx_Ports, E_Ports, and B_Ports, this object will typically have the value 'unknown'." ::= { fcmPortEntry 14 } --******************************** -- Port Statistics -- fcmPortStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of statistics for Fibre Channel ports." ::= { fcmgmtObjects 4 } fcmPortStatsEntry OBJECT-TYPE SYNTAX FcmPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing statistics for a Fibre Channel port. If any counter in this table suffers a discontinuity, the value of ifCounterDiscontinuityTime (defined in the IF-MIB) must be updated." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." AUGMENTS { fcmPortEntry } ::= { fcmPortStatsTable 1 } FcmPortStatsEntry ::= SEQUENCE { fcmPortBBCreditZeros Counter64, fcmPortFullInputBuffers Counter64, fcmPortClass2RxFrames Counter64, fcmPortClass2RxOctets Counter64, fcmPortClass2TxFrames Counter64, fcmPortClass2TxOctets Counter64, fcmPortClass2Discards Counter64, fcmPortClass2RxFbsyFrames Counter64, fcmPortClass2RxPbsyFrames Counter64, fcmPortClass2RxFrjtFrames Counter64, fcmPortClass2RxPrjtFrames Counter64, fcmPortClass2TxFbsyFrames Counter64, fcmPortClass2TxPbsyFrames Counter64, fcmPortClass2TxFrjtFrames Counter64, fcmPortClass2TxPrjtFrames Counter64,
fcmPortClass3RxFrames Counter64, fcmPortClass3RxOctets Counter64, fcmPortClass3TxFrames Counter64, fcmPortClass3TxOctets Counter64, fcmPortClass3Discards Counter64, fcmPortClassFRxFrames Counter32, fcmPortClassFRxOctets Counter32, fcmPortClassFTxFrames Counter32, fcmPortClassFTxOctets Counter32, fcmPortClassFDiscards Counter32 } fcmPortBBCreditZeros OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit." ::= { fcmPortStatsEntry 1 } fcmPortFullInputBuffers OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side." ::= { fcmPortStatsEntry 2 } fcmPortClass2RxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames received at this port." ::= { fcmPortStatsEntry 3 } fcmPortClass2RxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames received at this port."
::= { fcmPortStatsEntry 4 } fcmPortClass2TxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames transmitted out of this port." ::= { fcmPortStatsEntry 5 } fcmPortClass2TxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames transmitted out of this port." ::= { fcmPortStatsEntry 6 } fcmPortClass2Discards OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames that were discarded upon reception at this port." ::= { fcmPortStatsEntry 7 } fcmPortClass2RxFbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port." ::= { fcmPortStatsEntry 8 } fcmPortClass2RxPbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the
destination port is temporarily busy." ::= { fcmPortStatsEntry 9 } fcmPortClass2RxFrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port." ::= { fcmPortStatsEntry 10 } fcmPortClass2RxPrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port." ::= { fcmPortStatsEntry 11 } fcmPortClass2TxFbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port." ::= { fcmPortStatsEntry 12 } fcmPortClass2TxPbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because the destination port was temporarily busy. Note that this counter will never increment for an F_Port." ::= { fcmPortStatsEntry 13 }
fcmPortClass2TxFrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was generated by this port as a result of a Class 2 frame being rejected by the fabric. Note that this counter will never increment for an N_Port." ::= { fcmPortStatsEntry 14 } fcmPortClass2TxPrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was generated by this port as a result of a Class 2 frame being rejected at the destination N_Port. Note that this counter will never increment for an F_Port." ::= { fcmPortStatsEntry 15 } fcmPortClass3RxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames received at this port." ::= { fcmPortStatsEntry 16 } fcmPortClass3RxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames received at this port." ::= { fcmPortStatsEntry 17 } fcmPortClass3TxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames transmitted out of this port." ::= { fcmPortStatsEntry 18 }
fcmPortClass3TxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames transmitted out of this port." ::= { fcmPortStatsEntry 19 } fcmPortClass3Discards OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames that were discarded upon reception at this port." ::= { fcmPortStatsEntry 20 } fcmPortClassFRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class F frames received at this port." ::= { fcmPortStatsEntry 21 } fcmPortClassFRxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class F frames received at this port." ::= { fcmPortStatsEntry 22 } fcmPortClassFTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class F frames transmitted out of this port." ::= { fcmPortStatsEntry 23 }
fcmPortClassFTxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class F frames transmitted out of this port." ::= { fcmPortStatsEntry 24 } fcmPortClassFDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class F frames that were discarded upon reception at this port." ::= { fcmPortStatsEntry 25 } --******************************** -- Port Low-capacity Statistics -- -- these are Counter32 "low-capacity" counters for systems -- that do not support Counter64's fcmPortLcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmPortLcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Counter32-based statistics for systems that do not support Counter64." ::= { fcmgmtObjects 5 } fcmPortLcStatsEntry OBJECT-TYPE SYNTAX FcmPortLcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing low-capacity (i.e., based on Counter32) statistics for a Fibre Channel port. If any counter in this table suffers a discontinuity, the value of ifCounterDiscontinuityTime (defined in the IF-MIB) must be updated." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." AUGMENTS { fcmPortEntry } ::= { fcmPortLcStatsTable 1 }
FcmPortLcStatsEntry ::= SEQUENCE { fcmPortLcBBCreditZeros Counter32, fcmPortLcFullInputBuffers Counter32, fcmPortLcClass2RxFrames Counter32, fcmPortLcClass2RxOctets Counter32, fcmPortLcClass2TxFrames Counter32, fcmPortLcClass2TxOctets Counter32, fcmPortLcClass2Discards Counter32, fcmPortLcClass2RxFbsyFrames Counter32, fcmPortLcClass2RxPbsyFrames Counter32, fcmPortLcClass2RxFrjtFrames Counter32, fcmPortLcClass2RxPrjtFrames Counter32, fcmPortLcClass2TxFbsyFrames Counter32, fcmPortLcClass2TxPbsyFrames Counter32, fcmPortLcClass2TxFrjtFrames Counter32, fcmPortLcClass2TxPrjtFrames Counter32, fcmPortLcClass3RxFrames Counter32, fcmPortLcClass3RxOctets Counter32, fcmPortLcClass3TxFrames Counter32, fcmPortLcClass3TxOctets Counter32, fcmPortLcClass3Discards Counter32 } fcmPortLcBBCreditZeros OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit." ::= { fcmPortLcStatsEntry 1 } fcmPortLcFullInputBuffers OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side." ::= { fcmPortLcStatsEntry 2 }
fcmPortLcClass2RxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames received at this port." ::= { fcmPortLcStatsEntry 3 } fcmPortLcClass2RxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames received at this port." ::= { fcmPortLcStatsEntry 4 } fcmPortLcClass2TxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames transmitted out of this port." ::= { fcmPortLcStatsEntry 5 } fcmPortLcClass2TxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames transmitted out of this port." ::= { fcmPortLcStatsEntry 6 } fcmPortLcClass2Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames that were discarded upon reception at this port." ::= { fcmPortLcStatsEntry 7 }
fcmPortLcClass2RxFbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port." ::= { fcmPortLcStatsEntry 8 } fcmPortLcClass2RxPbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the destination port is temporarily busy." ::= { fcmPortLcStatsEntry 9 } fcmPortLcClass2RxFrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port." ::= { fcmPortLcStatsEntry 10 } fcmPortLcClass2RxPrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port." ::= { fcmPortLcStatsEntry 11 }
fcmPortLcClass2TxFbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port." ::= { fcmPortLcStatsEntry 12 } fcmPortLcClass2TxPbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because the destination port was temporarily busy. Note that this counter will never increment for an F_Port." ::= { fcmPortLcStatsEntry 13 } fcmPortLcClass2TxFrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was generated by this port as a result of a Class 2 frame being rejected by the fabric. Note that this counter will never increment for an N_Port." ::= { fcmPortLcStatsEntry 14 } fcmPortLcClass2TxPrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was generated by this port as a result of a Class 2 frame being rejected at the destination N_Port. Note that this counter will never increment for an F_Port." ::= { fcmPortLcStatsEntry 15 }
fcmPortLcClass3RxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames received at this port." ::= { fcmPortLcStatsEntry 16 } fcmPortLcClass3RxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames received at this port." ::= { fcmPortLcStatsEntry 17 } fcmPortLcClass3TxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames transmitted out of this port." ::= { fcmPortLcStatsEntry 18 } fcmPortLcClass3TxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames transmitted out of this port." ::= { fcmPortLcStatsEntry 19 } fcmPortLcClass3Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames that were discarded upon reception at this port." ::= { fcmPortLcStatsEntry 20 }
--******************************** -- Port Error Counters -- fcmPortErrorsTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmPortErrorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Error counters for Fibre Channel ports." ::= { fcmgmtObjects 6 } fcmPortErrorsEntry OBJECT-TYPE SYNTAX FcmPortErrorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Error counters for a Fibre Channel port. If any counter in this table suffers a discontinuity, the value of ifCounterDiscontinuityTime (defined in the IF-MIB) must be updated." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." AUGMENTS { fcmPortEntry } ::= { fcmPortErrorsTable 1 } FcmPortErrorsEntry ::= SEQUENCE { fcmPortRxLinkResets Counter32, fcmPortTxLinkResets Counter32, fcmPortLinkResets Counter32, fcmPortRxOfflineSequences Counter32, fcmPortTxOfflineSequences Counter32, fcmPortLinkFailures Counter32, fcmPortLossofSynchs Counter32, fcmPortLossofSignals Counter32, fcmPortPrimSeqProtocolErrors Counter32, fcmPortInvalidTxWords Counter32, fcmPortInvalidCRCs Counter32, fcmPortInvalidOrderedSets Counter32, fcmPortFrameTooLongs Counter32, fcmPortTruncatedFrames Counter32, fcmPortAddressErrors Counter32, fcmPortDelimiterErrors Counter32, fcmPortEncodingDisparityErrors Counter32, fcmPortOtherErrors Counter32 }
fcmPortRxLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Reset (LR) Primitive Sequences received." ::= { fcmPortErrorsEntry 1 } fcmPortTxLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Reset (LR) Primitive Sequences transmitted." ::= { fcmPortErrorsEntry 2 } fcmPortLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the reset link protocol was initiated on this port. This includes the number of Loop Initialization Primitive (LIP) events on an arbitrated loop port." ::= { fcmPortErrorsEntry 3 } fcmPortRxOfflineSequences OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline (OLS) Primitive Sequences received at this port." ::= { fcmPortErrorsEntry 4 } fcmPortTxOfflineSequences OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline (OLS) Primitive Sequences transmitted by this port." ::= { fcmPortErrorsEntry 5 }
fcmPortLinkFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link failures. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8 [FC-PH]." ::= { fcmPortErrorsEntry 6 } fcmPortLossofSynchs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of instances of synchronization loss detected at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { fcmPortErrorsEntry 7 } fcmPortLossofSignals OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of instances of signal loss detected at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { fcmPortErrorsEntry 8 } fcmPortPrimSeqProtocolErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of primitive sequence protocol errors detected at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { fcmPortErrorsEntry 9 }
fcmPortInvalidTxWords OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid transmission words received at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { fcmPortErrorsEntry 10 } fcmPortInvalidCRCs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received with an invalid CRC. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { fcmPortErrorsEntry 11 } fcmPortInvalidOrderedSets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid ordered sets received at this port." ::= { fcmPortErrorsEntry 12 } fcmPortFrameTooLongs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received at this port for which the frame length was greater than what was agreed to in FLOGI/PLOGI. This could be caused by losing the end of frame delimiter." ::= { fcmPortErrorsEntry 13 } fcmPortTruncatedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received at this port for which the
frame length was less than the minimum indicated by the frame header - normally 24 bytes, but it could be more if the DFCTL field indicates an optional header should have been present." ::= { fcmPortErrorsEntry 14 } fcmPortAddressErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received with unknown addressing; for example, an unknown SID or DID." ::= { fcmPortErrorsEntry 15 } fcmPortDelimiterErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid frame delimiters received at this port. An example is a frame with a class 2 start and a class 3 at the end." ::= { fcmPortErrorsEntry 16 } fcmPortEncodingDisparityErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of encoding disparity errors received at this port." ::= { fcmPortErrorsEntry 17 } fcmPortOtherErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of errors that were detected on this port but not counted by any other error counter in this row." ::= { fcmPortErrorsEntry 18 }
--******************************** -- The Fibre Channel Fx_Port Table -- fcmFxPortTable OBJECT-TYPE SYNTAX SEQUENCE OF FcmFxPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Additional information about Fibre Channel ports that is specific to Fx_Ports. This table will contain one entry for each fcmPortTable entry that represents an Fx_Port." ::= { fcmgmtObjects 7 } fcmFxPortEntry OBJECT-TYPE SYNTAX FcmFxPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about a specific Fx_Port." INDEX { ifIndex } ::= { fcmFxPortTable 1 } FcmFxPortEntry ::= SEQUENCE { fcmFxPortRatov Unsigned32, fcmFxPortEdtov Unsigned32, fcmFxPortRttov Unsigned32, fcmFxPortHoldTime Unsigned32, fcmFxPortCapBbCreditMax FcBbCredit, fcmFxPortCapBbCreditMin FcBbCredit, fcmFxPortCapDataFieldSizeMax FcDataFieldSize, fcmFxPortCapDataFieldSizeMin FcDataFieldSize, fcmFxPortCapClass2SeqDeliv TruthValue, fcmFxPortCapClass3SeqDeliv TruthValue, fcmFxPortCapHoldTimeMax Unsigned32, fcmFxPortCapHoldTimeMin Unsigned32 } fcmFxPortRatov OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Resource_Allocation_Timeout Value configured for this Fx_Port. This is used as the timeout value for determining when to reuse an Nx_Port resource such as a
Recovery_Qualifier. It represents the Error_Detect_Timeout value (see fcmFxPortEdtov) plus twice the maximum time that a frame may be delayed within the Fabric and still be delivered." ::= { fcmFxPortEntry 1 } fcmFxPortEdtov OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Error_Detect_Timeout value configured for this Fx_Port. This is used as the timeout value for detecting an error condition." ::= { fcmFxPortEntry 2 } fcmFxPortRttov OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Receiver_Transmitter_Timeout value of this Fx_Port. This is used by the receiver logic to detect a Loss of Synchronization." ::= { fcmFxPortEntry 3 } fcmFxPortHoldTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum time that this Fx_Port shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that this Fx_Port does not support this parameter." ::= { fcmFxPortEntry 4 } fcmFxPortCapBbCreditMax OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of receive buffers that this port is capable of making available for holding frames from attached
Nx_Port(s)." ::= { fcmFxPortEntry 5 } fcmFxPortCapBbCreditMin OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum number of receive buffers that this port is capable of making available for holding frames from attached Nx_Port(s)." ::= { fcmFxPortEntry 6 } fcmFxPortCapDataFieldSizeMax OBJECT-TYPE SYNTAX FcDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size in bytes of the Data Field in a frame that this Fx_Port is capable of receiving from an attached Nx_Port." ::= { fcmFxPortEntry 7 } fcmFxPortCapDataFieldSizeMin OBJECT-TYPE SYNTAX FcDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum size in bytes of the Data Field in a frame that this Fx_Port is capable of receiving from an attached Nx_Port." ::= { fcmFxPortEntry 8 } fcmFxPortCapClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this Fx_Port is capable of supporting Class 2 Sequential Delivery." ::= { fcmFxPortEntry 9 }