Tech-invite3GPPspaceIETFspace
96959493929190898887868584838281807978777675747372717069686766656463626160595857565554535251504948474645444342414039383736353433323130292827262524232221201918171615141312111009080706050403020100
in Index   Prev   Next

RFC 1382

SNMP MIB Extension for the X.25 Packet Layer

Pages: 69
Proposed Standard
Part 2 of 3 – Pages 7 to 39
First   Prev   Next

Top   ToC   RFC1382 - Page 7   prevText
4.  Object Definitions


          RFC1382-MIB DEFINITIONS ::= BEGIN

          IMPORTS
                  Counter, Gauge, TimeTicks
                          FROM RFC1155-SMI
                  OBJECT-TYPE
                          FROM RFC-1212
                  DisplayString, transmission
                          FROM RFC1213-MIB
                  TRAP-TYPE
                          FROM RFC-1215
                  EntryStatus
                          FROM RFC1271-MIB
                  PositiveInteger,
                  IfIndexType
                          FROM RFC1381-MIB;

          x25     OBJECT IDENTIFIER ::= { transmission 5 }


          -- Support of the X25 subtree and all subtrees under it
          -- is mandatory for all agents of system that implement X.25.

          X121Address ::= OCTET STRING (SIZE(0..17))
           -- 0 to 17 bytes in length containing the ASCII
           -- characters [0-9], each octet contains one digit
           -- of the address.


          -- ###########################################################
          --            X.25 Administration Table
          -- ###########################################################

          x25AdmnTable OBJECT-TYPE
Top   ToC   RFC1382 - Page 8
                  SYNTAX  SEQUENCE OF X25AdmnEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "This table contains the administratively
                          set configuration parameters for an X.25
                          Packet Level Entity (PLE).

                         Most of the objects in this table have
                          corresponding objects in the x25OperTable.
                          This table contains the values as last set
                          by the administrator.  The x25OperTable
                          contains the values actually in use by an
                          X.25 PLE.

                          Changing an administrative value may or may
                          not change a current operating value.  The
                          operating value may not change until the
                          interface is restarted.  Some
                          implementations may change the values
                          immediately upon changing the administrative
                          table.  All implementations are required to
                          load the values from the administrative
                          table when initializing a PLE."
                  ::= { x25 1 }

          x25AdmnEntry OBJECT-TYPE
                  SYNTAX  X25AdmnEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25AdmnTable."
                  INDEX { x25AdmnIndex }
                  ::= { x25AdmnTable 1 }

          X25AdmnEntry ::= SEQUENCE {
                  x25AdmnIndex
                          IfIndexType,
                  x25AdmnInterfaceMode
                          INTEGER,
                  x25AdmnMaxActiveCircuits
                          INTEGER,
                  x25AdmnPacketSequencing
                          INTEGER,
                  x25AdmnRestartTimer
                          PositiveInteger,
               x25AdmnCallTimer
                          PositiveInteger,
Top   ToC   RFC1382 - Page 9
                  x25AdmnResetTimer
                          PositiveInteger,
                  x25AdmnClearTimer
                          PositiveInteger,
                  x25AdmnWindowTimer
                          PositiveInteger,
                  x25AdmnDataRxmtTimer
                          PositiveInteger,
                  x25AdmnInterruptTimer
                          PositiveInteger,
                  x25AdmnRejectTimer
                          PositiveInteger,
                  x25AdmnRegistrationRequestTimer
                          PositiveInteger,
                  x25AdmnMinimumRecallTimer
                          PositiveInteger,
                  x25AdmnRestartCount
                          INTEGER,
                  x25AdmnResetCount
                          INTEGER,
                  x25AdmnClearCount
                          INTEGER,
                  x25AdmnDataRxmtCount
                          INTEGER,
                  x25AdmnRejectCount
                          INTEGER,
                  x25AdmnRegistrationRequestCount
                          INTEGER,
                  x25AdmnNumberPVCs
                          INTEGER,
                  x25AdmnDefCallParamId
                          OBJECT IDENTIFIER,
                  x25AdmnLocalAddress
                          X121Address,
                  x25AdmnProtocolVersionSupported
                          OBJECT IDENTIFIER
                  }

          x25AdmnIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The ifIndex value for the X.25 Interface."
                  ::= { x25AdmnEntry 1 }

          x25AdmnInterfaceMode OBJECT-TYPE
                  SYNTAX  INTEGER {
Top   ToC   RFC1382 - Page 10
                                  dte (1),
                                  dce (2),
                                  dxe (3)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Identifies DCE/DTE mode in which the
                          interface operates.  A value of dxe
                          indicates the mode will be determined by XID
                          negotiation."
                  REFERENCE "10733 5.9 interfaceMode"
                  ::= { x25AdmnEntry 2 }

          x25AdmnMaxActiveCircuits        OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The maximum number of circuits this PLE can
                          support; including PVCs."
                  REFERENCE "10733 5.9 maxActiveCircuits;
                          See ISO 8208, Section 3.7"
                  ::= { x25AdmnEntry 3 }

          x25AdmnPacketSequencing OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  modulo8 (1),
                                  modulo128 (2)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The modulus of the packet sequence number
                          space."
                  REFERENCE "10733 extendedPacketSequencing;
                          See ISO 8208 Section 7.1.1"
                  ::= { x25AdmnEntry 4 }

          x25AdmnRestartTimer OBJECT-TYPE
               SYNTAX     PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T20 restart timer in milliseconds."
                  REFERENCE "10733 5.9 restartTime
                          See ISO 8208 Section 4.1, table 26"
                  ::= { x25AdmnEntry 5 }
Top   ToC   RFC1382 - Page 11
          x25AdmnCallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T21 Call timer in milliseconds."
                  REFERENCE "10733 callTime;
                          See ISO 8208 Section 5.2.1, table 26"
                  ::= { x25AdmnEntry 6 }

          x25AdmnResetTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T22 Reset timer in milliseconds."
                  REFERENCE "10733 resetTime;
                          See ISO 8208 Section 8.1, table 26"
                  ::= { x25AdmnEntry 7 }

          x25AdmnClearTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T23 Clear timer in milliseconds."
                  REFERENCE "10733 clearTime;
                          See ISO 8208 Section 5.5.1, table 26"
                  ::= { x25AdmnEntry 8 }

          x25AdmnWindowTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T24 window status transmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no window timer in use."
                  REFERENCE "10733 5.10.1 windowTime (opt);
                          See ISO 8208 Section 11.2.2, table 26"
                  ::= { x25AdmnEntry 9 }

          x25AdmnDataRxmtTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T25 data retransmission timer in
Top   ToC   RFC1382 - Page 12
                          milliseconds.  A value of 2147483647
                          indicates no data retransmission timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
                          See ISO 8208 Section 11.2.1, table 26"
                  ::= { x25AdmnEntry 10 }

          x25AdmnInterruptTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T26 interrupt timer in milliseconds.  A
                          value of 2147483647 indicates no interrupt
                          timer in use."
                  REFERENCE "10733 interruptTime;
                          See ISO 8208 Section 6.8.1, table 26"
                  ::= { x25AdmnEntry 11 }

          x25AdmnRejectTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T27 Reject retransmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no reject timer in use."
                  REFERENCE "10733 5.10.1 dataRejectTime (opt);
                          See ISO 8208 Section 13.4.1, table 26"
                  ::= { x25AdmnEntry 12 }

          x25AdmnRegistrationRequestTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T28 registration timer in milliseconds.
                          A value of 2147483647 indicates no
                          registration timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestTime (opt)
                          See ISO 8208    Section 13.1.1.1, table 26"
                  ::= { x25AdmnEntry 13 }

          x25AdmnMinimumRecallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
Top   ToC   RFC1382 - Page 13
                          "Minimum time interval between unsuccessful
                          call attempts in milliseconds."
                  REFERENCE "10733 5.9 minimum RecallTimer"
                  ::= { x25AdmnEntry 14 }

          x25AdmnRestartCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R20 restart retransmission count."
                  REFERENCE "10733 5.9 restartCount;
                          See ISO 8208    Section 4.1, table 27"
                  ::= { x25AdmnEntry 15 }

          x25AdmnResetCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The r22 Reset retransmission count."
                  REFERENCE "10733 resetCount;
                          See section ISO 8208 8.1, table 27"
                  ::= { x25AdmnEntry 16 }

          x25AdmnClearCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The r23 Clear retransmission count."
                  REFERENCE "10733 clearCount;
                          See ISO 8208 Section 5.5.1, table 27"
                  ::= { x25AdmnEntry 17 }

          x25AdmnDataRxmtCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R25 Data retransmission count.  This
                          value is irrelevant if the
                          x25AdmnDataRxmtTimer indicates no timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionCount (opt)
                          See ISO 8208 Section 11.2.1, table 27"
                  ::= { x25AdmnEntry 18 }
Top   ToC   RFC1382 - Page 14
          x25AdmnRejectCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R27 reject retransmission count.  This
                          value is irrelevant if the
                          x25AdmnRejectTimer indicates no timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRejectCount (opt)"
                  ::= { x25AdmnEntry 19 }

          x25AdmnRegistrationRequestCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R28 Registration retransmission Count.
                          This value is irrelevant if the
                          x25AdmnRegistrationRequestTimer indicates no
                          timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestCount (opt);
                          See ISO 8208    Section 13.1.1.1, table 27"
                  ::= { x25AdmnEntry 20 }

          x25AdmnNumberPVCs OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PVC configured for this PLE.
                          The PVCs use channel numbers from 1 to this
                          number."
                  ::= { x25AdmnEntry 21 }

          x25AdmnDefCallParamId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the
                          x25CallParmIndex for the entry in the
                          x25CallParmTable which contains the default
                          call parameters for this PLE."
                  ::= { x25AdmnEntry 22 }

          x25AdmnLocalAddress OBJECT-TYPE
                  SYNTAX  X121Address
Top   ToC   RFC1382 - Page 15
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The local address for this PLE subnetwork.
                          A zero length address maybe returned by PLEs
                          that only support PVCs."
                  REFERENCE "10733 5.9 localDTEAddress"
                  ::= { x25AdmnEntry 23 }

          x25AdmnProtocolVersionSupported OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Identifies the version of the X.25 protocol
                          this interface should support.  Object
                          identifiers for common versions are defined
                          below in the x25ProtocolVersion subtree."
                  REFERENCE "10733 5.9 protocolVersionSupported"
                  ::= { x25AdmnEntry 24 }


          -- ###########################################################
          --            X.25 Operational Table
          -- ###########################################################

          x25OperTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25OperEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "The operation parameters in use by the X.25
                          PLE."
                  ::= { x25 2 }

          x25OperEntry OBJECT-TYPE
                  SYNTAX  X25OperEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25OperTable."
                  INDEX { x25OperIndex }
                  ::= { x25OperTable 1 }

          X25OperEntry ::= SEQUENCE {
                  x25OperIndex
                          IfIndexType,
                  x25OperInterfaceMode
Top   ToC   RFC1382 - Page 16
                          INTEGER,
                  x25OperMaxActiveCircuits
                          INTEGER,
                  x25OperPacketSequencing
                          INTEGER,
                  x25OperRestartTimer
                          PositiveInteger,
                  x25OperCallTimer
                          PositiveInteger,
                  x25OperResetTimer
                          PositiveInteger,
                  x25OperClearTimer
                          PositiveInteger,
                  x25OperWindowTimer
                          PositiveInteger,
                  x25OperDataRxmtTimer
                          PositiveInteger,
                  x25OperInterruptTimer
                          PositiveInteger,
                  x25OperRejectTimer
                          PositiveInteger,
               x25OperRegistrationRequestTimer
                          PositiveInteger,
                  x25OperMinimumRecallTimer
                          PositiveInteger,
                  x25OperRestartCount
                          INTEGER,
                  x25OperResetCount
                          INTEGER,
                  x25OperClearCount
                          INTEGER,
                  x25OperDataRxmtCount
                          INTEGER,
                  x25OperRejectCount
                          INTEGER,
                  x25OperRegistrationRequestCount
                          INTEGER,
                  x25OperNumberPVCs
                          INTEGER,
                  x25OperDefCallParamId
                          OBJECT IDENTIFIER,
                  x25OperLocalAddress
                          X121Address,
                  x25OperDataLinkId
                          OBJECT IDENTIFIER,
                  x25OperProtocolVersionSupported
                          OBJECT IDENTIFIER
                  }
Top   ToC   RFC1382 - Page 17
          x25OperIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 interface."
                  ::= { x25OperEntry 1 }

          x25OperInterfaceMode OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  dte (1),
                                  dce (2),
                                  dxe (3)
                          }
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "Identifies DCE/DTE mode in which the
                          interface operates.  A value of dxe
                          indicates the role will be determined by XID
                          negotiation at the Link Layer and that
                          negotiation has not yet taken place."
                  REFERENCE "10733 5.9 interfaceMode"
                  ::= { x25OperEntry 2 }

          x25OperMaxActiveCircuits        OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "Maximum number of circuits this PLE can
                          support."
                  REFERENCE "10733 5.9 maxActiveCircuits
                          See ISO 8208, Section 3.7"
                  ::= { x25OperEntry 3 }

          x25OperPacketSequencing OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  modulo8 (1),
                                  modulo128 (2)
                          }
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The modulus of the packet sequence number
                          space."
                  REFERENCE "10733 extendedPacketSequencing;
                          See ISO 8208    Section 7.1.1"
Top   ToC   RFC1382 - Page 18
                  ::= { x25OperEntry 4 }

          x25OperRestartTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T20 restart timer in milliseconds."
                  REFERENCE "10733 5.9 restartTime;
                          See ISO 8208    Section 4.1, table 26"
                  ::= { x25OperEntry 5 }

          x25OperCallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T21 Call timer in milliseconds."
                  REFERENCE "10733 callTime;
                          See ISO 8208 Section 5.2.1, table 26"
                  ::= { x25OperEntry 6 }

          x25OperResetTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T22 Reset timer in milliseconds."
                  REFERENCE "10733 resetTime;
                          See ISO 8208    Section 8.1, table 26"
                  ::= { x25OperEntry 7 }

          x25OperClearTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T23 Clear timer in milliseconds."
                  REFERENCE "10733 clearTime;
                          See ISO 8208 Section 5.5.1, table 26"
                  ::= { x25OperEntry 8 }

          x25OperWindowTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T24 window status transmission timer
Top   ToC   RFC1382 - Page 19
                          milliseconds.  A value of 2147483647
                          indicates no window timer in use."
                  REFERENCE "10733 5.10.1 windowTime (opt);
                          See ISO 8208 Section 11.2.2, table 26"
                  ::= { x25OperEntry 9 }

          x25OperDataRxmtTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T25 Data Retransmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no data retransmission timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
                          See ISO 8208 Section 11.2.1, table 26"
                  ::= { x25OperEntry 10 }

          x25OperInterruptTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T26 Interrupt timer in milliseconds.  A
                          value of 2147483647 indicates interrupts are
                          not being used."
                  REFERENCE "10733 interruptTime;
                          See ISO 8208 Section 6.8.1, table 26"
                  ::= { x25OperEntry 11 }

          x25OperRejectTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T27 Reject retransmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no reject timer in use."
                  REFERENCE "10733 5.10.1 dataRejectTime (opt);
                          See ISO 8208 Section 13.4.1, table 26"
                  ::= { x25OperEntry 12 }

          x25OperRegistrationRequestTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
Top   ToC   RFC1382 - Page 20
                          "The T28 registration timer in milliseconds.
                          A value of 2147483647 indicates no
                          registration timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestTime (opt);
                          See ISO 8208    Section 13.1.1.1, table 26"
                  ::= { x25OperEntry 13 }

          x25OperMinimumRecallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "Minimum time interval between unsuccessful
                          call attempts in milliseconds."
                  REFERENCE "10733 5.9 minimum RecallTimer"
                  ::= { x25OperEntry 14 }

          x25OperRestartCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R20 restart retransmission count."
                  REFERENCE "10733 5.9 restartCount
                          See ISO 8208    Section 4.1, table 27"
                  ::= { x25OperEntry 15 }

          x25OperResetCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The r22 Reset retransmission count."
                  REFERENCE "10733 resetCount;
                          See section ISO 8208 8.1, table 27"
                  ::= { x25OperEntry 16 }

          x25OperClearCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The r23 Clear retransmission count."
                  REFERENCE "10733 clearCount;
                          See ISO 8208 Section 5.5.1, table 27"
                  ::= { x25OperEntry 17 }

          x25OperDataRxmtCount OBJECT-TYPE
Top   ToC   RFC1382 - Page 21
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R25 Data retransmission count.  This
                          value is undefined if the
                          x25OperDataRxmtTimer indicates no timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionCount (opt);
                          See ISO 8208 Section 11.2.1, table 27"
                  ::= { x25OperEntry 18 }

          x25OperRejectCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R27 reject retransmission count.  This
                          value is undefined if the x25OperRejectTimer
                          indicates no timer in use."
                  REFERENCE "10733 5.10.1 dataRejectCount (opt)"
                  ::= { x25OperEntry 19 }

          x25OperRegistrationRequestCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R28 Registration retransmission Count.
                          This value is undefined if the
                          x25OperREgistrationRequestTimer indicates no
                          timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestCount (opt);
                          See ISO 8208    Section 13.1.1.1, table 27"
                  ::= { x25OperEntry 20 }

          x25OperNumberPVCs OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PVC configured for this PLE.
                          The PVCs use channel numbers from 1 to this
                          number."
                  ::= { x25OperEntry 21 }

          x25OperDefCallParamId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
Top   ToC   RFC1382 - Page 22
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the
                          x25CallParmIndex for the entry in the
                          x25CallParmTable that contains the default
                          call parameters for this PLE."
                  ::= { x25OperEntry 22 }

          x25OperLocalAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The local address for this PLE subnetwork.
                          A zero length address maybe returned by PLEs
                          that only support PVCs."
                  REFERENCE "10733 5.9 localDTEAddress"
                  ::= { x25OperEntry 23 }

          x25OperDataLinkId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the index
                          object in the first table of the most device
                          specific MIB for the interface used by this
                          PLE."
                  ::= { x25OperEntry 24 }

          x25OperProtocolVersionSupported OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "Identifies the version of the X.25 protocol
                          this interface supports.  Object identifiers
                          for common versions are defined below in the
                          x25ProtocolVersion subtree."
                  REFERENCE "10733 5.9 protocolVersionSupported"
                  ::= { x25OperEntry 25 }


          --      MIB-II also provides:

          -- ifDescr:
          -- On an X.25 interface this must include sufficient
Top   ToC   RFC1382 - Page 23
          -- information to enable the system's administrator
          -- to determine the appropriate configuration
          -- information on a system having multiple X.25
          -- subnetworks.

          -- ifType: ddn-x25 or rfc877-x25
          --      an interface of type ddn-x25 will use an algorithm to
          --      translate between X.121 address and IP addresses.
          --      An interface of type rfc877-x25 will use a
          --      configuration table to translate between X.121
          --      addresses and IP addresses.

          -- ifMtu: the maximum PDU a higher layer can pass to X.25 or
          -- receive from X.25

          -- ifSpeed:
          -- This will be the value of the local clock for this line.
          -- A value of zero indicates external clocking.

          -- ifAdminStatus:

          -- ifOperStatus

          -- ifLastChange


          -- ###########################################################
          --            X.25 Statistics Table
          -- ###########################################################

          x25StatTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25StatEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Statistics information about this X.25
                          PLE."
                  ::= { x25 3 }

          x25StatEntry OBJECT-TYPE
                  SYNTAX  X25StatEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                           "Entries of the x25StatTable."
                           INDEX { x25StatIndex }
                  ::= { x25StatTable 1 }
Top   ToC   RFC1382 - Page 24
          X25StatEntry ::= SEQUENCE {
                  x25StatIndex
                          IfIndexType,
                  x25StatInCalls
                          Counter,
                  x25StatInCallRefusals
                          Counter,
                  x25StatInProviderInitiatedClears
                          Counter,
                  x25StatInRemotelyInitiatedResets
                          Counter,
                  x25StatInProviderInitiatedResets
                          Counter,
                  x25StatInRestarts
                          Counter,
                  x25StatInDataPackets
                          Counter,
                  x25StatInAccusedOfProtocolErrors
                          Counter,
                  x25StatInInterrupts
                          Counter,
                  x25StatOutCallAttempts
                          Counter,
                  x25StatOutCallFailures
                          Counter,
                  x25StatOutInterrupts
                          Counter,
                  x25StatOutDataPackets
                          Counter,
                  x25StatOutgoingCircuits
                          Gauge,
                  x25StatIncomingCircuits
                          Gauge,
                  x25StatTwowayCircuits
                          Gauge,
                  x25StatRestartTimeouts
                          Counter,
                  x25StatCallTimeouts
                          Counter,
                  x25StatResetTimeouts
                          Counter,
                  x25StatClearTimeouts
                          Counter,
                  x25StatDataRxmtTimeouts
                          Counter,
                  x25StatInterruptTimeouts
                          Counter,
                  x25StatRetryCountExceededs
Top   ToC   RFC1382 - Page 25
                          Counter,
                  x25StatClearCountExceededs
                          Counter
                  }

          x25StatIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 interface."
                  ::= { x25StatEntry 1 }

          x25StatInCalls OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of incoming calls received."
                  ::= { x25StatEntry 2 }

          x25StatInCallRefusals OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of incoming calls refused.  This
                          includes calls refused by the PLE and by
                          higher layers.  This also includes calls
                          cleared because of restricted fast select."
                  ::= { x25StatEntry 3 }

          x25StatInProviderInitiatedClears        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of clear requests with a cause
                          code other than DTE initiated."
                          REFERENCE "10733 providerInitiatedDisconnect"
                  ::= { x25StatEntry 4 }

          x25StatInRemotelyInitiatedResets        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of reset requests received with
Top   ToC   RFC1382 - Page 26
                          cause code DTE initiated."
                  REFERENCE "10733 remotelyInitiatedResets"
                  ::= { x25StatEntry 5 }

          x25StatInProviderInitiatedResets        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of reset requests received with
                          cause code other than DTE initiated."
                  REFERENCE "10733 ProviderInitiatedResets"
                  ::= { x25StatEntry 6 }

          x25StatInRestarts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of remotely initiated (including
                          provider initiated) restarts experienced by
                          the PLE excluding the restart associated
                          with bringing up the PLE interface.  This
                          only counts restarts received when the PLE
                          already has an established connection with
                          the remove PLE."
                  REFERENCE "10733 5.9 remotelyInitiatedRestarts"
                  ::= { x25StatEntry 7 }

          x25StatInDataPackets    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of data packets received."
                          REFERENCE "10733 5.9 dataPacketsReceived."
                  ::= { x25StatEntry 8 }

          x25StatInAccusedOfProtocolErrors        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of packets received containing a
                          procedure error cause code.  These include
                          clear, reset, restart, or diagnostic
                          packets."
                  REFERENCE "CD 10733 5.9 accusedOfProtocolError"
Top   ToC   RFC1382 - Page 27
                  ::= { x25StatEntry 9 }

          x25StatInInterrupts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets received by
                          the PLE or over the PVC/VC."
                  REFERENCE "10733 interruptPacketsReceived"
                  ::= { x25StatEntry 10 }

          x25StatOutCallAttempts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of calls attempted."
                  REFERENCE "10733 5.9 callAttempts"
                  ::= { x25StatEntry 11 }

          x25StatOutCallFailures OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of call attempts which failed.
                          This includes calls that were cleared
                          because of restrictive fast select."
                  ::= { x25StatEntry 12 }

          x25StatOutInterrupts    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets send by the
                          PLE or over the PVC/VC."
                  REFERENCE "10733 InterruptPacketsSent"
                  ::= { x25StatEntry 13 }

          x25StatOutDataPackets   OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of data packets sent by this
                          PLE."
Top   ToC   RFC1382 - Page 28
                  REFERENCE "10733 dataPacketSent"
                  ::= { x25StatEntry 14 }

          x25StatOutgoingCircuits OBJECT-TYPE
                  SYNTAX  Gauge
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of active outgoing circuits.
                          This includes call requests sent but not yet
                          confirmed.  This does not count PVCs."
                  ::= { x25StatEntry 15 }

          x25StatIncomingCircuits OBJECT-TYPE
                  SYNTAX  Gauge
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of active Incoming Circuits.
                          This includes call indications received but
                          not yet acknowledged.  This does not count
                          PVCs."
                  ::= { x25StatEntry 16 }

          x25StatTwowayCircuits   OBJECT-TYPE
                  SYNTAX  Gauge
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The number of active two-way Circuits.
                          This includes call requests sent but not yet
                          confirmed.  This does not count PVCs."
                  ::= { x25StatEntry 17 }

          x25StatRestartTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T20 restart timer
                          expired."
                  REFERENCE "10733 5.9 restartTimeouts"
                  ::= { x25StatEntry 18 }

          x25StatCallTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
Top   ToC   RFC1382 - Page 29
                  DESCRIPTION
                          "The number of times the T21 call timer
                          expired."
                  REFERENCE "10733 5.9 callTimeouts"
                  ::= { x25StatEntry 19 }

          x25StatResetTimeouts    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T22 reset timer
                          expired."
                  REFERENCE "10733 5.9 resetTimeouts"
                  ::= { x25StatEntry 20 }

          x25StatClearTimeouts    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T23 clear timer
                          expired."
                  REFERENCE "10733 5.9 clearTimeouts"
                  ::= { x25StatEntry 21 }

          x25StatDataRxmtTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T25 data timer
                          expired."
                  REFERENCE "10733 5.9 dataRetransmissionsTimerExpiries"
                  ::= { x25StatEntry 22 }

          x25StatInterruptTimeouts        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T26 interrupt timer
                          expired."
                  REFERENCE "10733 5.9 interruptTimerExpires"
                  ::= { x25StatEntry 23 }

          x25StatRetryCountExceededs OBJECT-TYPE
                  SYNTAX  Counter
Top   ToC   RFC1382 - Page 30
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times a retry counter was
                          exhausted."
                  REFERENCE "10733 5.9 retryCountsExceeded"
                  ::= { x25StatEntry 24 }

          x25StatClearCountExceededs OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the R23 clear count was
                          exceeded."
                  REFERENCE "10733 5.9 clearCountsExceeded"
                  ::= { x25StatEntry 25 }


          --      MIB-II also contains:

          -- ifInOctets: Number of data octets delivered to upper
          -- layer entities.

          -- ifInUcastPkts: Number of packets with a clear M-bit
          -- delivered to higher layer entities.

          -- ifDiscards: Number of packets dropped for lack of buffering

          -- ifInErrors: Number of packets received containing errors
            -- REFERENCE ProtocolErrorsDetectedLocally

          -- ifInUnknownProtos: Number of packets with unknown circuit
          -- identifier.

          -- ifOutOctets: Number of data octets delivered by
          --      X.25 to upper layers.

          -- ifOutUcastPkts: Number of packets with a clear M-bit
          -- received from higher layer entities.


          -- ###########################################################
          --                    X.25 Channel Table
          -- ###########################################################

          x25ChannelTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25ChannelEntry
Top   ToC   RFC1382 - Page 31
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "These objects contain information about the
                          channel number configuration in an X.25 PLE.
                          These values are the configured values.
                          changes in these values after the interfaces
                          has started may not be reflected in the
                          operating PLE."
                  REFERENCE "See ISO 8208, Section 3.7"
                  ::= { x25 4 }

          x25ChannelEntry OBJECT-TYPE
                  SYNTAX  X25ChannelEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25ChannelTable."
                  REFERENCE "This provides the information available
                          in 10733 logicalChannelAssignments."
                  INDEX { x25ChannelIndex }
                  ::= { x25ChannelTable 1    }

          X25ChannelEntry ::= SEQUENCE {
                  x25ChannelIndex
                          IfIndexType,
                  x25ChannelLIC
                          INTEGER,
                  x25ChannelHIC
                          INTEGER,
                  x25ChannelLTC
                          INTEGER,
                  x25ChannelHTC
                          INTEGER,
                  x25ChannelLOC
                          INTEGER,
                  x25ChannelHOC
                          INTEGER
                  }

          x25ChannelIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 Interface."
                  ::= { x25ChannelEntry 1 }
Top   ToC   RFC1382 - Page 32
          x25ChannelLIC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Lowest Incoming channel."
                  ::= { x25ChannelEntry 2 }

          x25ChannelHIC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Highest Incoming channel.  A value of zero
                          indicates no channels in this range."
                  ::= { x25ChannelEntry 3 }

          x25ChannelLTC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Lowest Two-way channel."
                  ::= { x25ChannelEntry 4 }

          x25ChannelHTC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Highest Two-way channel.  A value of zero
                          indicates no channels in this range."
                  ::= { x25ChannelEntry 5 }

          x25ChannelLOC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Lowest outgoing channel."
                  ::= { x25ChannelEntry 6 }

          x25ChannelHOC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Highest outgoing channel.  A value of zero
Top   ToC   RFC1382 - Page 33
                          indicates no channels in this range."
                  ::= { x25ChannelEntry 7 }




          -- ###########################################################
          --          X25 Per Circuits Information Table
          -- ###########################################################

          x25CircuitTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25CircuitEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "These objects contain general information
                          about a specific circuit of an X.25 PLE."
                  ::= { x25 5 }

          x25CircuitEntry OBJECT-TYPE
                  SYNTAX  X25CircuitEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25CircuitTable."
                  INDEX { x25CircuitIndex,
                          x25CircuitChannel }
                  ::= { x25CircuitTable 1 }

          X25CircuitEntry ::= SEQUENCE {
                  x25CircuitIndex
                          IfIndexType,
                  x25CircuitChannel
                          INTEGER,
                  x25CircuitStatus
                          INTEGER,
                  x25CircuitEstablishTime
                          TimeTicks,
                  x25CircuitDirection
                          INTEGER,
                  x25CircuitInOctets
                          Counter,
                  x25CircuitInPdus
                          Counter,
                  x25CircuitInRemotelyInitiatedResets
                          Counter,
                  x25CircuitInProviderInitiatedResets
                          Counter,
Top   ToC   RFC1382 - Page 34
                  x25CircuitInInterrupts
                          Counter,
                  x25CircuitOutOctets
                          Counter,
                  x25CircuitOutPdus
                          Counter,
                  x25CircuitOutInterrupts
                          Counter,
                  x25CircuitDataRetransmissionTimeouts
                          Counter,
                  x25CircuitResetTimeouts
                          Counter,
                  x25CircuitInterruptTimeouts
                          Counter,
                  x25CircuitCallParamId
                          OBJECT IDENTIFIER,
                  x25CircuitCalledDteAddress
                          X121Address,
                  x25CircuitCallingDteAddress
                          X121Address,
                  x25CircuitOriginallyCalledAddress
                          X121Address,
                  x25CircuitDescr
                          DisplayString
                  }

          x25CircuitIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 Interface."
                  ::= { x25CircuitEntry 1 }

          x25CircuitChannel OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The channel number for this circuit."
                  ::= { x25CircuitEntry 2 }

          x25CircuitStatus OBJECT-TYPE
                  SYNTAX  INTEGER {               -- state table states
                                  invalid (1),
                                  closed (2),             -- (p1)
                                  calling (3),            -- (p2,p3,p5)
                                  open (4),               -- (p4)
Top   ToC   RFC1382 - Page 35
                                  clearing (5),           -- (p6,p7)
                                  pvc (6),
                                  pvcResetting (7),
                                  startClear (8),         -- Close cmd
                                  startPvcResetting (9),  -- Reset cmd
                                  other (10)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "This object reports the current status of
                          the circuit.

                          An existing instance of this object can only
                          be set to startClear, startPvcResetting, or
                          invalid.  An instance with the value calling
                          or open can only be set to startClear and
                          that action will start clearing the circuit.
                          An instance with the value PVC can only be
                          set to startPvcResetting or invalid and that
                          action resets the PVC or deletes the circuit
                          respectively.  The values startClear or
                          startPvcResetting will never be returned by
                          an agent.  An attempt to set the status of
                          an existing instance to a value other than
                          one of these values will result in an error.

                          A non-existing instance can be set to PVC to
                          create a PVC if the implementation supports
                          dynamic creation of PVCs.  Some
                          implementations may only allow creation and
                          deletion of PVCs if the interface is down.
                          Since the instance identifier will supply
                          the PLE index and the channel number,
                          setting this object alone supplies
                          sufficient information to create the
                          instance.  All the DEFVAL clauses for the
                          other objects of this table are appropriate
                          for creating a PVC; PLEs creating entries
                          for placed or accepted calls will use values
                          appropriate for the call rather than the
                          value of the DEFVAL clause.  Two managers
                          trying to create the same PVC can determine
                          from the return code which manager succeeded
                          and which failed (the failing manager fails
                          because it can not set a value of PVC for an
                          existing object).
Top   ToC   RFC1382 - Page 36
                          An entry in the closed or invalid state may
                          be deleted or reused at the agent's
                          convence.  If the entry is kept in the
                          closed state, the values of the parameters
                          associated with the entry must be correct.
                          Closed implies the values in the circuit
                          table are correct.

                          The value of invalid indicates the other
                          values in the table are invalid.  Many
                          agents may never return a value of invalid
                          because they dynamically allocate and free
                          unused table entries.  An agent for a
                          statically configured systems can return
                          invalid to indicate the entry has not yet
                          been used so the counters contain no
                          information."
                  REFERENCE "See ISO 8208,
                                  table 33 for (p<n>) state table"
                  ::= { x25CircuitEntry 3 }

          x25CircuitEstablishTime OBJECT-TYPE
                  SYNTAX  TimeTicks
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The value of sysUpTime when the channel was
                          associated with this circuit.  For outgoing
                          SVCs, this is the time the first call packet
                          was sent.  For incoming SVCs, this is the
                          time the call indication was received.  For
                          PVCs this is the time the PVC was able to
                          pass data to a higher layer entity without
                          loss of data."
                  ::= { x25CircuitEntry 4 }

          x25CircuitDirection OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  incoming (1),
                                  outgoing (2),
                                  pvc (3)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The direction of the call that established
                          this circuit."
                  REFERENCE "10733 direction"
Top   ToC   RFC1382 - Page 37
                  DEFVAL { pvc }
                  ::= { x25CircuitEntry 5 }

                          -- X25 Circuit data flow statistics

          x25CircuitInOctets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of octets of user data delivered
                          to upper layer."
                  REFERENCE "5.11 octetsReceivedCounter"
                  ::= { x25CircuitEntry 6 }

          x25CircuitInPdus OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PDUs received for this
                          circuit."
                  REFERENCE "10733 5.11 dataPacketsReceived"
                  ::= { x25CircuitEntry 7 }

          x25CircuitInRemotelyInitiatedResets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of Resets received for this
                          circuit with cause code of DTE initiated."
                  REFERENCE "10733 remotelyInitiatedResets"
                  ::= { x25CircuitEntry 8 }

          x25CircuitInProviderInitiatedResets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of Resets received for this
                          circuit with cause code other than DTE
                          initiated."
                  REFERENCE "10733 ProviderInitiatedResets"
                  ::= { x25CircuitEntry 9 }

          x25CircuitInInterrupts OBJECT-TYPE
                  SYNTAX  Counter
Top   ToC   RFC1382 - Page 38
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets received
                          for this circuit."
                  REFERENCE "10733 interruptPacketsReceived"
                  ::= { x25CircuitEntry 10 }

          x25CircuitOutOctets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of octets of user data sent for
                          this circuit."
                  REFERENCE "10733 5.11 octetsSentCounter"
                  ::= { x25CircuitEntry 11 }

          x25CircuitOutPdus OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PDUs sent for this circuit."
                  REFERENCE "10733 5.11 dataPacketsSent"
                  ::= { x25CircuitEntry 12 }

          x25CircuitOutInterrupts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets sent on
                          this circuit."
                  REFERENCE "10733 interruptPacketsSent"
                  ::= { x25CircuitEntry 13 }


                          -- X25 circuit timer statistics

          x25CircuitDataRetransmissionTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T25 data
                          retransmission timer expired for this
                          circuit."
Top   ToC   RFC1382 - Page 39
                  REFERENCE "10733 5.11 dataRetransmissionTimerExpiries"
                  ::= { x25CircuitEntry 14 }

          x25CircuitResetTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T22 reset timer
                          expired for this circuit."
                  REFERENCE "10733 5.11 resetTimeouts"
                  ::= { x25CircuitEntry 15 }

          x25CircuitInterruptTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T26 Interrupt timer
                          expired for this circuit."
                  REFERENCE "10733 interruptTimerExpiries"
                  ::= { x25CircuitEntry 16 }

          x25CircuitCallParamId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the
                          x25CallParmIndex for the entry in the
                          x25CallParmTable which contains the call
                          parameters in use with this circuit.  The
                          entry referenced must contain the values
                          that are currently in use by the circuit
                          rather than proposed values.  A value of
                          NULL indicates the circuit is a PVC or is
                          using all the default parameters."
                  DEFVAL { {0 0} }
                  ::= { x25CircuitEntry 17 }

          x25CircuitCalledDteAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "For incoming calls, this is the called
                          address from the call indication packet.
                          For outgoing calls, this is the called


(next page on part 3)

Next Section