Tech-invite3GPPspaceIETFspace
96959493929190898887868584838281807978777675747372717069686766656463626160595857565554535251504948474645444342414039383736353433323130292827262524232221201918171615141312111009080706050403020100
in Index   Prev   Next

RFC 5098

Signaling MIB for PacketCable and IPCablecom Multimedia Terminal Adapters (MTAs)

Pages: 79
Proposed Standard
Errata
Updated by:  9141
Part 2 of 3 – Pages 6 to 48
First   Prev   Next

Top   ToC   RFC5098 - Page 6   prevText

5. Definitions

PKTC-IETF-SIG-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, mib-2 FROM SNMPv2-SMI -- [RFC2578] InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB -- [RFC4001] TEXTUAL-CONVENTION, RowStatus, TruthValue FROM SNMPv2-TC -- [RFC2579]
Top   ToC   RFC5098 - Page 7
    OBJECT-GROUP,
    MODULE-COMPLIANCE
          FROM SNMPv2-CONF                  -- [RFC2580]
    SnmpAdminString
          FROM SNMP-FRAMEWORK-MIB           -- [RFC3411]
    ifIndex
          FROM IF-MIB                       -- [RFC2863]
    Dscp
          FROM DIFFSERV-DSCP-TC;            -- [RFC3289]

pktcIetfSigMib MODULE-IDENTITY
    LAST-UPDATED    "200712180000Z" -- December 18, 2007
    ORGANIZATION    "IETF IPCDN Working Group"
    CONTACT-INFO
        "Sumanth Channabasappa
         Cable Television Laboratories, Inc.
         858 Coal Creek Circle,
         Louisville, CO 80027, USA
         Phone: +1 303-661-3307
         Email: Sumanth@cablelabs.com

         Gordon Beacham
         Motorola, Inc.
         6450 Sequence Drive, Bldg. 1
         San Diego, CA 92121, USA
         Phone: +1 858-404-2334
         Email: gordon.beacham@motorola.com

         Satish Kumar Mudugere Eswaraiah
         Texas Instruments India (P) Ltd.,
         Golf view, Wind Tunnel Road
         Murugesh Palya
         Bangalore 560 017, INDIA
         Phone:   +91 80 5269451
         Email:  satish.kumar@ti.com

    IETF IPCDN Working Group
         General Discussion: ipcdn@ietf.org
         Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
         Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
         Co-Chair: Jean-Francois Mule, jf.mule@cablelabs.com
         Co-Chair: Richard Woundy, Richard_Woundy@cable.comcast.com"

    DESCRIPTION
       "This MIB module supplies the basic management
        objects for the PacketCable and IPCablecom Signaling
        protocols.  This version of the MIB includes
        common signaling and Network Call Signaling
Top   ToC   RFC5098 - Page 8
        (NCS)-related signaling objects.

        Copyright (C) The IETF Trust (2008).  This version of
        this MIB module is part of RFC 5098; see the RFC itself for
        full legal notices."
    REVISION                "200712180000Z"
    DESCRIPTION
       "Initial version, published as RFC 5098."

::=  { mib-2 169 }

-- Textual Conventions

TenthdBm ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d-1"
    STATUS       current
    DESCRIPTION
        "This TEXTUAL-CONVENTION represents power levels that are
         normally expressed in dBm.  Units are in tenths of a dBm;
         for example, -13.5 dBm will be represented as -135."
    SYNTAX       Integer32

PktcCodecType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        " This TEXTUAL-CONVENTION defines various types of codecs
          that MAY be supported.  The description for each
          enumeration is listed below:

          Enumeration     Description
          other           a defined codec not in the enumeration
          unknown         a codec not defined by the PacketCable
                          Codec Specification
          g729            ITU-T Recommendation G.729
          reserved        for future use
          g729E           ITU-T Recommendation G.729E
          pcmu            Pulse Code Modulation u-law (PCMU)
          g726at32        ITU-T Recommendation G.726-32 (32 kbit/s)
          g728            ITU-T Recommendation G.728
          pcma            Pulse Code Modulation a-law (PCMA)
          g726at16        ITU-T Recommendation G.726-16 (16 kbit/s)
          g726at24        ITU-T Recommendation G.726-24 (24 kbit/s)
          g726at40        ITU-T Recommendation G.726-40 (40 kbit/s)
          ilbc            IETF Internet low-bit rate codec
          bv16            Broadcom BroadVoice16

          The list of codecs is consistent with the IETF
          Real-Time Transport Protocol (RTP) Profile registry and
Top   ToC   RFC5098 - Page 9
          the RTP Map Parameters Table in PacketCable Audio/Video
          Codecs Specification [PKT-SP-CODEC].  The literal codec
          name for each codec is listed below:

          Codec     Literal Codec Name
          g729              G729
          g729E             G729E
          pcmu              PCMU
          g726at32          G726-32
          g728              G728
          pcma              PCMA
          g726at16          G726-16
          g726at24          G726-24
          g726at40          G726-40
          ilbc              iLBC
          bv16              BV16

          The literal codec name is the second column of the table
          with codec RTP Map Parameters.  The Literal Codec Name Column
          contains the codec name used in the local connection
          options (LCO) of the NCS messages create connection
          (CRCX)/modify connection (MDCX) and is also used to
          identify the codec in the Call Management System (CMS)
          Provisioning Specification.  The RTP Map Parameter column of
          the Table contains the string used in the media attribute
          line (a=) of the session description protocol (SDP)
          parameters in NCS messages."
    SYNTAX INTEGER {
               other     (1),
               unknown   (2),
               g729      (3),
               reserved  (4),
               g729E     (5),
               pcmu      (6),
               g726at32  (7),
               g728      (8),
               pcma      (9),
               g726at16  (10),
               g726at24  (11),
               g726at40  (12),
               ilbc      (13),
               bv16      (14)
    }

PktcRingCadence   ::= TEXTUAL-CONVENTION
    STATUS        current
    DESCRIPTION
          "This object provides an encoding scheme for ring
Top   ToC   RFC5098 - Page 10
          cadences, including repeatability characteristics.  All
          fields in this object MUST be encoded in network-byte
          order.

          The first three higher-order octets are reserved.  The
          octets that follow are used to encode a 'bit-string', with
          each bit corresponding to 50 milliseconds.  A bit value of
          '1' indicates the presence of a ring-tone, and a bit value
          of '0' indicates the absence of a ring-tone, for that
          duration (50 ms) (Note: A minimum number of octets
          required to encode the bit-string MUST be used).

          The first two of the reserved octets MUST indicate the
          length of the encoded cadence (in bits) and MUST range
          between 1 and 264.  (Note: The length in bits MUST also be
          consistent with the number of octets that encode the
          cadence).  The MTA MUST ignore any unused bits in the last
          octet, but MUST reflect the value as provided on
          subsequent SNMP GETs.

          The third of the reserved octets indicates 'repeatability'
          and MUST be either 0x80 or 0x00 -- the former value
          indicating 'non-repeatability', and the latter indicating
          'repeatability'.

          The MTA MUST reject attempts to set a value that violates
          any of the above requirements."


    SYNTAX  OCTET STRING (SIZE(4..36))


PktcSigType     ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        " This object lists the various types of signaling that may
          be supported:

          other(1) - set when signaling other than NCS is used
          ncs(2)   - Network Call Signaling is a derivation of MGCP
                    (Media Gateway Control Protocol) defined for
                     IPCablecom/PacketCable MTAs."
    SYNTAX INTEGER {
                   other(1),
                   ncs(2)
    }
Top   ToC   RFC5098 - Page 11
DtmfCode::=TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "This TEXTUAL-CONVENTION represents the Dual-Tone
         Multi-Frequency (DTMF) Character used
         to indicate the start or end of the digit transition
         sequence used for caller id or Visual Message Waiting
         Indicator (VMWI).

         Note: The DTMF code '*' is indicated using 'dtmfcodeStar',
         and the DTMF code '#' is indicated using ' dtmfcodeHash'."
    SYNTAX       INTEGER {
                  dtmfcode0(0),
                  dtmfcode1(1),
                  dtmfcode2(2),
                  dtmfcode3(3),
                  dtmfcode4(4),
                  dtmfcode5(5),
                  dtmfcode6(6),
                  dtmfcode7(7),
                  dtmfcode8(8),
                  dtmfcode9(9),
                  dtmfcodeStar(10),
                  dtmfcodeHash(11),
                  dtmfcodeA(12),
                  dtmfcodeB(13),
                  dtmfcodeC(14),
                  dtmfcodeD(15)
}

PktcSubscriberSideSigProtocol::=TEXTUAL-CONVENTION
    STATUS  current
    DESCRIPTION
        "This TEXTUAL-CONVENTION represents the Signaling
         protocol being used for purposes such as caller id
         or VMWI.

         A value of fsk(1) indicates Frequency Shift Keying
         (FSK).
         A value of dtmf(2) indicates Dual-Tone Multi-Frequency
         (DTMF)."
         SYNTAX INTEGER {
                fsk(1),
                dtmf(2)
         }

pktcSigMibObjects OBJECT IDENTIFIER ::= { pktcIetfSigMib 1 }
pktcSigDevObjects OBJECT IDENTIFIER ::=
Top   ToC   RFC5098 - Page 12
                                        { pktcSigMibObjects 1 }
pktcSigEndPntConfigObjects OBJECT IDENTIFIER ::=
                                        { pktcSigMibObjects 2 }
--
-- The codec table (pktcSigDevCodecTable) defines all combinations
-- of codecs supported by the Multimedia Terminal Adapter (MTA).
--
pktcSigDevCodecTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PktcSigDevCodecEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
         " This table describes the MTA-supported codec types.  An MTA
          MUST populate this table with all possible combinations of
          codecs it supports for simultaneous operation.  For example,
          an MTA with two endpoints may be designed with a particular
          Digital Signal Processing (DSP) and memory architecture that
          allows it to support the following fixed combinations of
          codecs for simultaneous operation:

          Codec Type     Maximum Number of Simultaneous Codecs
          PCMA                             3

          PCMA                             2
          PCMU                             1

          PCMA                             1

          PCMU                             2

          PCMU                             3

          PCMA                             1
          G729                             1

          G729                             2

          PCMU                             1
          G729                             1

          Based on this example, the entries in the codec table
          would be:

            pktcSigDev        pktcSigDev        pktcSigDev
          CodecComboIndex     CodecType          CodecMax
                 1               pcma                3
                 2               pcma                2
                 2               pcmu                1
Top   ToC   RFC5098 - Page 13
                 3               pcma                1
                 3               pcmu                2
                 4               pcmu                3
                 5               pcma                1
                 5               g729                1
                 6               g729                2
                 7               pcmu                1
                 7               g729                1

          An operator querying this table is able to determine all
          possible codec combinations the MTA is capable of
          simultaneously supporting.

          This table MUST NOT include non-voice codecs."
    ::= { pktcSigDevObjects 1 }

pktcSigDevCodecEntry  OBJECT-TYPE
    SYNTAX      PktcSigDevCodecEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry represents the maximum number of active
         connections with a particular codec the MTA is capable of
         supporting.  Each row is indexed by a composite key
         consisting of a number enumerating the particular codec
         combination and the codec type."
    INDEX { pktcSigDevCodecComboIndex, pktcSigDevCodecType }
    ::= { pktcSigDevCodecTable 1 }

PktcSigDevCodecEntry  ::= SEQUENCE {
    pktcSigDevCodecComboIndex    Unsigned32,
    pktcSigDevCodecType     PktcCodecType,
    pktcSigDevCodecMax      Unsigned32
    }

pktcSigDevCodecComboIndex  OBJECT-TYPE
    SYNTAX      Unsigned32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        " The index value that enumerates a particular codec
          combination in the pktcSigDevCodecTable."
    ::= { pktcSigDevCodecEntry 1 }

pktcSigDevCodecType  OBJECT-TYPE
    SYNTAX       PktcCodecType
    MAX-ACCESS   not-accessible
    STATUS       current
Top   ToC   RFC5098 - Page 14
    DESCRIPTION
        " A codec type supported by this MTA."
    ::= { pktcSigDevCodecEntry 2 }

pktcSigDevCodecMax  OBJECT-TYPE
    SYNTAX      Unsigned32(1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        " The maximum number of simultaneous sessions of a
          particular codec that the MTA can support."
    ::= { pktcSigDevCodecEntry 3 }

--
-- These are the common signaling-related definitions that affect
-- the entire MTA device.
--

pktcSigDevEchoCancellation  OBJECT-TYPE
    SYNTAX       TruthValue
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This object specifies if the device is capable of echo
          cancellation.  The MTA MUST set this MIB object to a
          value of true(1) if it is capable of echo
          cancellation, and a value of false(2) if not."
    ::= { pktcSigDevObjects 2 }

pktcSigDevSilenceSuppression  OBJECT-TYPE
    SYNTAX       TruthValue
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This object specifies if the device is capable of
          silence suppression (as a result of Voice Activity
          Detection).  The MTA MUST set this MIB object to a
          value of true(1) if it is capable of silence
          suppression, and a value of false(2) if not."
::= { pktcSigDevObjects 3 }

pktcSigDevCidSigProtocol  OBJECT-TYPE
    SYNTAX       PktcSubscriberSideSigProtocol
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        "This object is used to configure the subscriber-line
         protocol used for signaling on-hook caller id information.
Top   ToC   RFC5098 - Page 15
         Different countries define different caller id signaling
         protocols to support caller identification.

         Setting this object at a value fsk(1) sets the subscriber
         line protocol to be Frequency Shift Keying (FSK).

         Setting this object at a value dtmf(2) sets the subscriber
         line protocol to be Dual-Tone Multi-Frequency (DTMF).

         The value of this MIB object MUST NOT persist across MTA
         reboots."
     REFERENCE
        "ETSI-EN-300-659-1 Specification"
     DEFVAL { fsk }
::= { pktcSigDevObjects 4 }

pktcSigDevR0Cadence     OBJECT-TYPE
    SYNTAX      PktcRingCadence
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        " This object specifies ring cadence 0 (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 5 }

pktcSigDevR1Cadence     OBJECT-TYPE
    SYNTAX      PktcRingCadence
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        " This object specifies ring cadence 1 (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 6 }

pktcSigDevR2Cadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        " This object specifies ring cadence 2 (a user-defined
          field).
Top   ToC   RFC5098 - Page 16
          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 7 }

pktcSigDevR3Cadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies ring cadence 3 (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 8 }

pktcSigDevR4Cadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies ring cadence 4 (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 9 }

pktcSigDevR5Cadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies ring cadence 5 (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 10 }

pktcSigDevR6Cadence     OBJECT-TYPE
    SYNTAX      PktcRingCadence
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        " This object specifies ring cadence 6 (a user-defined
          field).
Top   ToC   RFC5098 - Page 17
          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 11 }

pktcSigDevR7Cadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies ring cadence 7 (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 12 }

pktcSigDevRgCadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies ring cadence rg (a user-defined
          field).

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 13 }

pktcSigDevRsCadence     OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies ring cadence rs (a user-defined
          field).  The MTA MUST reject any attempt to make this object
          repeatable.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 14 }

pktcSigDefCallSigDscp  OBJECT-TYPE
    SYNTAX      Dscp  -- RFC 3289: DIFFSERV-DSCP-TC
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        " The default value used in the IP header for setting the
          Differentiated Services Code Point (DSCP) value for call
Top   ToC   RFC5098 - Page 18
          signaling.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    DEFVAL { 0 }
    ::= { pktcSigDevObjects 15 }

pktcSigDefMediaStreamDscp  OBJECT-TYPE
    SYNTAX      Dscp  -- RFC 3289: DIFFSERV-DSCP-TC
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        " This object contains the default value used in the IP
          header for setting the Differentiated Services Code Point
          (DSCP) value for media stream packets.  The MTA MUST NOT
          update this object with the value supplied by the CMS in
          the NCS messages (if present).  Any currently active
          connections are not affected by updates to this object.
          When the value of this object is updated by SNMP, the MTA
          MUST use the new value as a default starting only from
          new connections.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    DEFVAL { 0 }
    ::= { pktcSigDevObjects 16 }

--
-- pktcSigCapabilityTable - This table defines the valid signaling
-- types supported by this MTA.
--

pktcSigCapabilityTable    OBJECT-TYPE
    SYNTAX        SEQUENCE OF PktcSigCapabilityEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " This table describes the signaling types supported by this
          MTA."
    ::= { pktcSigDevObjects 17 }

pktcSigCapabilityEntry    OBJECT-TYPE
    SYNTAX        PktcSigCapabilityEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " Entries in pktcMtaDevSigCapabilityTable - list of
          supported signaling types, versions, and vendor extensions
Top   ToC   RFC5098 - Page 19
          for this MTA.  Each entry in the list provides for one
          signaling type and version combination.  If the device
          supports multiple versions of the same signaling type, it
          will require multiple entries."
    INDEX { pktcSigCapabilityIndex }
    ::= { pktcSigCapabilityTable 1 }

PktcSigCapabilityEntry  ::= SEQUENCE {
    pktcSigCapabilityIndex             Unsigned32,
    pktcSigCapabilityType              PktcSigType,
    pktcSigCapabilityVersion           SnmpAdminString,
    pktcSigCapabilityVendorExt         SnmpAdminString
    }

pktcSigCapabilityIndex       OBJECT-TYPE
    SYNTAX        Unsigned32 (1..255)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " The index value that uniquely identifies an entry in the
          pktcSigCapabilityTable."
    ::= { pktcSigCapabilityEntry 1 }

pktcSigCapabilityType      OBJECT-TYPE
    SYNTAX        PktcSigType
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        " This object identifies the type of signaling used.  This
          value has to be associated with a single signaling
          version."
    ::= { pktcSigCapabilityEntry 2 }

pktcSigCapabilityVersion      OBJECT-TYPE
    SYNTAX        SnmpAdminString
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        " Provides the version of the signaling type - reference
          pktcSigCapabilityType.  Examples would be 1.0 or 2.33 etc."
    ::= { pktcSigCapabilityEntry 3 }

pktcSigCapabilityVendorExt      OBJECT-TYPE
    SYNTAX        SnmpAdminString
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        " The vendor extension allows vendors to provide a list of
Top   ToC   RFC5098 - Page 20
          additional capabilities.

          The syntax for this MIB object in ABNF ([RFC5234]) is
          specified to be zero or more occurrences of vendor
          extensions, as follows:

           pktcSigCapabilityVendorExt  = *(vendor-extension)
           vendor-extension = (ext symbol alphanum) DQUOTE ; DQUOTE
           ext      = DQUOTE %x58 DQUOTE
           symbol   = (DQUOTE %x2D DQUOTE)/(DQUOTE %x2D DQUOTE)
           alphanum = 1*6(ALPHA/DIGIT)

        "
    ::= { pktcSigCapabilityEntry 4 }

pktcSigDefNcsReceiveUdpPort  OBJECT-TYPE
    SYNTAX      InetPortNumber (1025..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        " This object contains the MTA User Datagram Protocol (UDP)
          receive port that is being used for NCS call signaling.
          This object should only be changed by the configuration
          file.

          Unless changed via configuration, this MIB object MUST
          reflect a value of '2427'."
    REFERENCE
        "PacketCable NCS Specification"
    ::= { pktcSigDevObjects 18 }

pktcSigPowerRingFrequency    OBJECT-TYPE
    SYNTAX       INTEGER {
                 f20Hz(1),
                 f25Hz(2),
                 f33Point33Hz(3),
                 f50Hz(4),
                 f15Hz(5),
                 f16Hz(6),
                 f22Hz(7),
                 f23Hz(8),
                 f45Hz(9)
    }
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This object must only be provided via the configuration
          file during the provisioning process.  The power ring
Top   ToC   RFC5098 - Page 21
          frequency is the frequency at which the sinusoidal voltage
          must travel down the twisted pair to make terminal
          equipment ring.  Different countries define different
          electrical characteristics to make terminal equipment
          ring.

          The f20Hz setting corresponds to a power ring frequency
          of 20 Hertz.  The f25Hz setting corresponds to a power ring
          frequency of 25 Hertz.  The f33Point33Hz setting
          corresponds to a power ring frequency of 33.33 Hertz.  The
          f50Hz setting corresponds to a power ring frequency of 50
          Hertz.  The f15Hz setting corresponds to a power ring
          frequency of 15 Hertz.  The f16Hz setting corresponds to a
          power ring frequency of 16 Hertz.  The f22Hz setting
          corresponds to a power ring frequency of 22 Hertz.  The
          f23Hz setting corresponds to a power ring frequency of 23
          Hertz.  The f45Hz setting corresponds to a power ring
          frequency of 45 Hertz."
    REFERENCE
          "ETSI-EN-300-001"
    ::= { pktcSigDevObjects 19 }

pktcSigPulseSignalTable    OBJECT-TYPE
    SYNTAX       SEQUENCE OF PktcSigPulseSignalEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " The Pulse signal table defines the pulse signal operation.
          There are nine types of international pulse signals,
          with each signal having a set of provisionable parameters.
          The values of the MIB objects in this table take effect
          only if these parameters are not defined via signaling, in
          which case, the latter determines the values of the
          parameters.  The MIB objects in this table do not persist
          across MTA reboots."
    REFERENCE
        "ETSI-TS-101-909-4 Specification"
    ::= { pktcSigDevObjects 20 }

pktcSigPulseSignalEntry    OBJECT-TYPE
    SYNTAX       PktcSigPulseSignalEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " This object defines the set of parameters associated with
          each particular value of pktcSigPulseSignalType.  Each
          entry in the pktcSigPulseSignalTable is indexed by the
          pktcSigPulseSignalType object.
Top   ToC   RFC5098 - Page 22
          The conceptual rows MUST NOT persist across MTA reboots."
    INDEX { pktcSigPulseSignalType }
    ::= { pktcSigPulseSignalTable 1 }

PktcSigPulseSignalEntry ::= SEQUENCE {
        pktcSigPulseSignalType              INTEGER,
        pktcSigPulseSignalFrequency         INTEGER,
        pktcSigPulseSignalDbLevel           TenthdBm,
        pktcSigPulseSignalDuration          Unsigned32,
        pktcSigPulseSignalPulseInterval     Unsigned32,
        pktcSigPulseSignalRepeatCount       Unsigned32
}

pktcSigPulseSignalType    OBJECT-TYPE
    SYNTAX       INTEGER
                 {
                     initialRing(1),
                     pulseLoopClose(2),
                     pulseLoopOpen(3),
                     enableMeterPulse(4),
                     meterPulseBurst(5),
                     pulseNoBattery(6),
                     pulseNormalPolarity(7),
                     pulseReducedBattery(8),
                     pulseReversePolarity(9)
                 }
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        "There are nine types of international pulse signals.  These
         signals are defined as follows:
         initial ring
         pulse loop close
         pulse loop open
         enable meter pulse
         meter pulse burst
         pulse no battery
         pulse normal polarity
         pulse reduced battery
         pulse reverse polarity"
    REFERENCE
        "ETSI-EN-300-324-1 Specification"

    ::= { pktcSigPulseSignalEntry 1 }

pktcSigPulseSignalFrequency    OBJECT-TYPE
    SYNTAX       INTEGER {
                 twentyfive(1),
Top   ToC   RFC5098 - Page 23
                 twelvethousand(2),
                 sixteenthousand(3)
    }
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object is only applicable to the initialRing,
          enableMeterPulse, and meterPulseBurst signal types.  This
          object identifies the frequency of the generated signal.
          The following table defines the default values for this
          object depending on signal type:

          pktcSigPulseSignalType     Default
          initialRing                25
          enableMeterPulse           16000
          meterPulseBurst            16000

          The value of twentyfive MUST only be used for the
          initialRing signal type.  The values of twelvethousand and
          sixteenthousand MUST only be used for enableMeterPulse and
          meterPulseBurst signal types.  An attempt to set this
          object while the value of pktcSigPulseSignalType is not
          initialRing, enableMeterPulse, or meterPulseBurst will
          result in an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-001 Specification"
         ::= { pktcSigPulseSignalEntry 2}

pktcSigPulseSignalDbLevel    OBJECT-TYPE
    SYNTAX       TenthdBm (-350..0)
    UNITS        "1/10 of a dBm"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object is only applicable to the enableMeterPulse and
          meterPulseBurst signal types.  This is the decibel level
          for each frequency at which tones could be generated at
          the a and b terminals (TE connection point).  An attempt to
          set this object while the value of pktcSigPulseSignalType
          is not enableMeterPulse or meterPulseBurst will result in
          an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-001 Specification"

    DEFVAL { -135 }
    ::={pktcSigPulseSignalEntry 3 }

pktcSigPulseSignalDuration    OBJECT-TYPE
Top   ToC   RFC5098 - Page 24
    SYNTAX       Unsigned32 (0..5000)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the pulse duration for each
          signal type.  In addition, the MTA must accept the values
          in the incremental steps specific for each signal type.
          The following table defines the default values and the
          incremental steps for this object depending on the signal
          type:

          pktcSigPulseSignaltype  Default (ms)   Increment (ms)
          initialRing                 200             50
          pulseLoopClose              200             10
          pulseLoopOpen               200             10
          enableMeterPulse            150             10
          meterPulseBurst             150             10
          pulseNoBattery              200             10
          pulseNormalPolarity         200             10
          pulseReducedBattery         200             10
          pulseReversePolarity        200             10

          An attempt to set this object to a value that does not
          fall on one of the increment boundaries, or on the wrong
          increment boundary for the specific signal type, will
          result in an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-324-1 Specification"
         ::= {pktcSigPulseSignalEntry 4 }

pktcSigPulseSignalPulseInterval     OBJECT-TYPE
    SYNTAX       Unsigned32 (0..5000)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the repeat interval, or the period,
          for each signal type.  In addition, the MTA must accept
          the values in the incremental steps specific for each
          signal type.  The following table defines the default
          values and the incremental steps for this object, depending
          on the signal type:

          pktcSigPulseSignaltype  Default (ms)   Increment (ms)
          initialRing                 200             50
          pulseLoopClose             1000             10
          pulseLoopOpen              1000             10
Top   ToC   RFC5098 - Page 25
          enableMeterPulse           1000             10
          meterPulseBurst            1000             10
          pulseNoBattery             1000             10
          pulseNormalPolarity        1000             10
          pulseReducedBattery        1000             10
          pulseReversePolarity       1000             10

          An attempt to set this object to a value that does not
          fall on one of the increment boundaries, or on the wrong
          increment boundary for the specific signal type, will
          result in an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-324-1 Specification"
         ::= { pktcSigPulseSignalEntry 5}

pktcSigPulseSignalRepeatCount    OBJECT-TYPE
    SYNTAX       Unsigned32 (1..50)
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies how many times to repeat a pulse.
          This object is not used by the enableMeterPulse signal
          type, and in that case, the value is irrelevant.  The
          following table defines the default values and the valid
          ranges for this object, depending on the signal type:

          pktcSigPulseSignaltype  Default   Range

          initialRing                1       1-5
          pulseLoopClose             1       1-50
          pulseLoopOpen              1       1-50
          enableMeterPulse      (any value)(but not used)
          meterPulseBurst            1       1-50
          pulseNoBattery             1       1-50
          pulseNormalPolarity        1       1-50
          pulseReducedBattery        1       1-50
          pulseReversePolarity       1       1-50

          An attempt to set this object to a value that does not
          fall within the range for the specific
          signal type will result in an 'inconsistentValue' error."
    ::={ pktcSigPulseSignalEntry 6 }

pktcSigDevCidMode    OBJECT-TYPE
    SYNTAX       INTEGER {
                 duringRingingETS(1),
                 dtAsETS(2),
                 rpAsETS(3),
Top   ToC   RFC5098 - Page 26
                 lrAsETS(4),
                 lrETS(5)
                 }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        " For on-hook caller id, pktcSigDevCidMode selects the method
          for representing and signaling caller identification.  For
          the duringRingingETS method, the Frequency Shift Keying
          (FSK) or the Dual-Tone Multi-Frequency (DTMF) containing
          the caller identification information is sent between the
          first and second ring pattern.

          For the dtAsETS,rpAsETS, lrAsETS and lrETS
          methods, the FSK or DTMF containing the caller id
          information is sent before the first ring pattern.

          For the dtAsETS method, the FSK or DTMF is sent after the
          Dual Tone Alert Signal.  For the rpAsETS method, the FSK or
          DTMF is sent after a Ring Pulse.

          For the lrAsETS method, the Line Reversal occurs first,
          then the Dual Tone Alert Signal, and, finally, the FSK or
          DTMF is sent.

          For the lrETS method, the Line Reversal occurs first,
          then the FSK or DTMF is sent.

          The value of this MIB object MUST NOT persist across MTA
          reboots."

    DEFVAL { rpAsETS}
    ::= {pktcSigDevObjects 21 }

pktcSigDevCidAfterRing     OBJECT-TYPE
    SYNTAX       Unsigned32 (0|50..2000)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of first
          ringing pattern and the start of the transmission of the
          FSK or DTMF containing the caller id information.  It is
          only used when pktcSigDevCidMode is set to a value of
          'duringRingingETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
Top   ToC   RFC5098 - Page 27
         (pktcSigDevCidMode), and MUST be followed:

          Value of pktcSigDevCidMode       Default value

          duringringingETS                 550 ms
          dtAsETS                          any value (not used)
          rpAsETS                          any value (not used)
          lrAsETS                          any value (not used)
          lrETS                            any value (not used)

          An attempt to set this object while the value of
          pktcSigDevCidMode is not duringringingETS will result in
          an 'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 550 }
    ::= {pktcSigDevObjects 22 }

pktcSigDevCidAfterDTAS    OBJECT-TYPE
    SYNTAX       Unsigned32 (0|45..500)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Dual Tone Alert Signal (DT-AS) and the start of the
          transmission of the FSK or DTMF containing the caller id
          information.  This object is only used when
          pktcSigDevCidMode is set to a value of 'dtAsETS' or
          'lrAsETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:

          Value of pktcSigDevCidMode       Default value


          duringringingETS                 any value (not used)
          dtAsETS                          50 ms
          rpAsETS                          any value (not used)
          lrAsETS                          50 ms
          lrETS                            any value (not used)

          An attempt to set this object while the value of
Top   ToC   RFC5098 - Page 28
          pktcSigDevCidMode is not 'dtAsETS' or 'lrAsETS' will
          result in an 'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 50 }
    ::= {pktcSigDevObjects 23 }

pktcSigDevCidAfterRPAS    OBJECT-TYPE
    SYNTAX       Unsigned32 (0|500..800)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Ring Pulse Alert Signal (RP-AS) and the start of the
          transmission of the FSK or DTMF containing the caller id
          information.  This MIB object is only used when
          pktcSigDevCidMode is set to a value of 'rpAsETS'.
          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:

          Value of pktcSigDevCidMode       Default value

          duringringingETS                 any value  (not used)
          dtAsETS                          any value  (not used)
          rpAsETS                          650 ms
          lrAsETS                          any value  (not used)
          lrETS                            any value  (not used)

          An attempt to set this object while the value of
          pktcSigDevCidMode is not 'rpAsETS' will result in an
          'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 650 }
    ::= {pktcSigDevObjects 24 }

pktcSigDevRingAfterCID    OBJECT-TYPE
    SYNTAX       Unsigned32 (0|50..500)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
Top   ToC   RFC5098 - Page 29
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          complete transmission of the FSK or DTMF containing the
          caller id information and the start of the first ring
          pattern.  It is only used when pktcSigDevCidMode is
          set to a value of 'dtAsETS', 'rpAsETS', 'lrAsETS' or
          'lrETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:

          Value of pktcSigDevCidMode       Default value

          duringringingETS                 any value  (not used)
          dtAsETS                          250 ms
          rpAsETS                          250 ms
          lrAsETS                          250 ms
          lrETS                            250 ms

          An attempt to set this object while the value of
          pktcSigDevCidMode is not 'dtAsETS', 'rpAsETS',
          'lrAsETS', or 'lrETS' will result in an 'inconsistent
          value' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 250 }
    ::= {pktcSigDevObjects 25 }

pktcSigDevCidDTASAfterLR    OBJECT-TYPE
    SYNTAX       Unsigned32 (50..655)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Line Reversal and the start of the Dual Tone Alert Signal
          (DT-AS).  This object is only used when pktcSigDevCidMode
          is set to a value of 'lrAsETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:
Top   ToC   RFC5098 - Page 30
          Value of pktcSigDevCidMode       Default value

          duringringingETS                 any value  (not used)
          dtAsETS                          any value  (not used)
          rpAsETS                          any value  (not used)
          lrAsETS                          250 ms
          lrETS                            any value  (not used)

          An attempt to set this object while the value of
          pktcSigDevCidMode is not lrAsETS will result in an
          'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 250 }

    ::= {pktcSigDevObjects 26 }

pktcSigDevVmwiMode    OBJECT-TYPE
    SYNTAX       INTEGER {
                 dtAsETS(1),
                 rpAsETS(2),
                 lrAsETS(3),
                 osi(4),
                 lrETS(5)
                 }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        " For visual message waiting indicator (VMWI),
          pktcSigDevVmwiMode selects the alerting signal method.  For
          the dtAsETS, rpAsETS, lrAsETS, osi, and lrETS methods,
          the FSK containing the VMWI information is sent after an
          alerting signal.

          For the dtAsETS method, the FSK, or DTMF
          is sent after the Dual Tone Alert Signal.  For the rpAsETS
          method, the FSK or DTMF is sent after a Ring Pulse.

          For the lrAsETS method, the Line Reversal occurs first,
          then the Dual Tone Alert Signal, and, finally, the FSK or
          DTMF is sent.

          For the OSI method, the FSK or DTMF is sent after the Open
          Switching Interval.
Top   ToC   RFC5098 - Page 31
          For the lrETS method, the Line Reversal occurs first,
          then the FSK or DTMF is sent.

          The value of this MIB object MUST NOT persist across MTA
          reboots."

    DEFVAL { rpAsETS }
    ::= {pktcSigDevObjects 27 }

pktcSigDevVmwiAfterDTAS    OBJECT-TYPE
    SYNTAX       Unsigned32 (0|45..500)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Dual Tone Alert Signal (DT-AS) and the start of the
          transmission of the FSK or DTMF containing the VMWI
          information.

          This object is only used when pktcSigDevVmwiMode is
          set to a value of 'dtAsETS' or 'lrAsETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevVmwiMode), and MUST be followed:

          Value of pktcSigDevVmwiMode       Default value

          dtAsETS                           50 ms
          rpAsETS                           any value  (not used)
          lrAsETS                           50 ms
          lrETS                             any value  (not used)

          An attempt to set this object while the value of
          pktcSigDevVmwiMode is not 'dtAsETS' or 'lrAsETS' will
          result in an 'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 50 }
    ::= {pktcSigDevObjects 28 }


pktcSigDevVmwiAfterRPAS    OBJECT-TYPE
    SYNTAX       Unsigned32 (0|500..800)
Top   ToC   RFC5098 - Page 32
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Ring Pulse Alert Signal (RP-AS) and the start of the
          transmission of the FSK or DTMF containing the VMWI
          information.

          This object is only used when pktcSigDevVmwiMode is
          set to a value of 'rpAsETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevVmwiMode), and MUST be followed:

          Value of pktcSigDevVmwiMode       Default value

          dtAsETS                           any value  (not used)
          rpAsETS                           650 ms
          lrAsETS                           any value  (not used)
          lrETS                             any value  (not used)

          An attempt to set this object while the value of
          pktcSigDevVmwiMode is not 'rpAsETS' will result in an
          'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 650 }
    ::= {pktcSigDevObjects 29 }

pktcSigDevVmwiDTASAfterLR    OBJECT-TYPE
    SYNTAX       Unsigned32 (0|50..655)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Line Reversal and the start of the Dual Tone Alert Signal
          (DT-AS) for VMWI information.  This object is only used
          when pktcSigDevVmwiMode is set to a value of 'lrAsETS'.

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevVmwiMode), and MUST be followed:
Top   ToC   RFC5098 - Page 33
          Value of pktcSigDevVmwiMode       Default value

          dtAsETS                           any value  (not used)
          rpAsETS                           any value  (not used)
          lrAsETS                           250 ms
          lrETS                             any value  (not used)

          An attempt to set this object while the value of
          pktcSigDevVmwiMode is not 'lrAsETS' will result in an
          'inconsistentValue' error.

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 250 }
    ::= {pktcSigDevObjects 30 }

pktcSigDevRingCadenceTable    OBJECT-TYPE
    SYNTAX       SEQUENCE OF PktcSigDevRingCadenceEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        "Cadence rings are defined by the telco governing
         body for each country.  The MTA must be able to support
         various ranges of cadence patterns and cadence periods.
         The MTA will be able to support country-specific
         provisioning of the cadence and idle period.  Each
         cadence pattern will be assigned a unique value ranging
         from 0-127 (inclusive) corresponding to the value of x,
         where x is the value sent in the cadence ringing (cr)
         signal cr(x), requested per the appropriate NCS
         message, and defined in the E package.  The MTA will derive
         the cadence periods from the ring cadence table entry, as
         provisioned by the customer.  The MTA is allowed to provide
         appropriate default values for each of the ring cadences.
         This table only needs to be supported when the MTA
         implements the E package."
    REFERENCE
        "ETSI-TS-101-909-4 Specification"
    ::= { pktcSigDevObjects 31 }

pktcSigDevRingCadenceEntry    OBJECT-TYPE
    SYNTAX       PktcSigDevRingCadenceEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
Top   ToC   RFC5098 - Page 34
        " Each entry in this row corresponds to a ring cadence
          that is being supported by the device.  The conceptual
          rows MUST NOT persist across MTA reboots."
    INDEX { pktcSigDevRingCadenceIndex }
    ::= { pktcSigDevRingCadenceTable 1 }

PktcSigDevRingCadenceEntry ::= SEQUENCE {
        pktcSigDevRingCadenceIndex       Unsigned32,
        pktcSigDevRingCadence            PktcRingCadence
    }

pktcSigDevRingCadenceIndex    OBJECT-TYPE
    SYNTAX       Unsigned32 (0..127)
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " A unique value ranging from 0 to 127 that corresponds to the
          value sent by the LE based on country-specific cadences,
          one row per cadence cycle.  In any given system
          implementation for a particular country, it is anticipated
          that a small number of ring cadences will be in use.  Thus,
          this table most likely will not be populated to its full
          size."
    ::= { pktcSigDevRingCadenceEntry 1 }

pktcSigDevRingCadence    OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        "This is the Ring Cadence."
    ::= { pktcSigDevRingCadenceEntry 2 }


pktcSigDevToneTable    OBJECT-TYPE
    SYNTAX       SEQUENCE OF PktcSigDevToneEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " The Tone Table defines the composition of tones and
          various tone operations.

          The definition of the tones callWaiting1 through
          callWaiting4 in this table MUST only contain the
          audible tone itself; the delay between tones or the value
          of the tone repeat count are not applicable for the call
          waiting tones.
Top   ToC   RFC5098 - Page 35
          The delay between tones or the repeat count is controlled
          by the objects pktcSigEndPntConfigCallWaitingDelay and
          pktcSigEndPntConfigCallWaitingMaxRep.  If the
          pktcSigDevToneType is set to either of the values
          callWaiting1, callWaiting2, callWaiting3, or callWaiting4,
          then the value of the pktcSigDevToneWholeToneRepeatCount
          object indicates that the particular frequency group is
          applicable, as a repeatable part of the tone, based on the
          value of the MIB object
          pktcSigDevToneWholeToneRepeatCount.

          The MTA MUST make sure that, after the provisioning
          cycle, the table is fully populated (i.e., for each
          possible index, an entry MUST be defined) using
          reasonable defaults for each row that was not defined
          by the provisioning information delivered via MTA
          Configuration.

          The frequency composition of each tone is defined by the
          pktcSigDevMultiFreqToneTable.  For each tone type defined
          in pktcSigDevToneTable, the MTA MUST populate at least
          one entry in the pktcSigDevMultiFreqToneTable.

          For each particular value of pktcSigDevToneType, the
          pktcSigDevToneTable table can define non-repeating and
          repeating groups of the frequencies defined by the
          pktcSigDevMultiFreqToneTable, such that each group is
          represented by the set of the consecutive rows
          (frequency group) in the pktcSigDevMultiFreqToneTable.

          Objects in this table do not persist across MTA reboots.
          For tones with multiple frequencies refer to the MIB table
          pktcSigDevMultiFreqToneTable."
    REFERENCE
        "PacketCable NCS Specification, ETSI-TS-101-909-4
         Specification."
    ::= { pktcSigDevObjects 32 }

pktcSigDevToneEntry    OBJECT-TYPE
    SYNTAX       PktcSigDevToneEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " The different tone types that can be provisioned based on
          country-specific needs.

          Each entry contains the tone generation parameters for
          a specific frequency group of the specific Tone Type.
Top   ToC   RFC5098 - Page 36
          The different parameters can be provisioned via MTA
          configuration based on country specific needs.
          An MTA MUST populate all entries of this table for each
          tone type."
    INDEX { pktcSigDevToneType, pktcSigDevToneFreqGroup }
    ::= { pktcSigDevToneTable 1 }

PktcSigDevToneEntry ::= SEQUENCE {
    pktcSigDevToneType                      INTEGER,
    pktcSigDevToneFreqGroup                 Unsigned32,
    pktcSigDevToneFreqCounter               Unsigned32,
    pktcSigDevToneWholeToneRepeatCount      Unsigned32,
    pktcSigDevToneSteady                    TruthValue
    }

pktcSigDevToneType        OBJECT-TYPE
    SYNTAX       INTEGER {
                 busy(1),
                 confirmation(2),
                 dial(3),
                 messageWaiting(4),
                 offHookWarning(5),
                 ringBack(6),
                 reOrder(7),
                 stutterdial(8),
                 callWaiting1(9),
                 callWaiting2(10),
                 callWaiting3(11),
                 callWaiting4(12),
                 alertingSignal(13),
                 specialDial(14),
                 specialInfo(15),
                 release(16),
                 congestion(17),
                 userDefined1(18),
                 userDefined2(19),
                 userDefined3(20),
                 userDefined4(21)
                 }
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        "A unique value that will correspond to the different
         tone types.  These tones can be provisioned based on
         country-specific needs.  This object defines the type
         of tone being accessed.

         The alertingSignal, specialDial, specialInfo, release,
Top   ToC   RFC5098 - Page 37
         congestion, userDefined1, userDefined2, userDefined3,
         and userDefined4 tone types are used in
         the E line package."
    ::= { pktcSigDevToneEntry 1 }

pktcSigDevToneFreqGroup  OBJECT-TYPE
       SYNTAX       Unsigned32(1..4)
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION
           "This MIB object represents the Tone Sequence reference
           of a multi-sequence tone."
       ::={ pktcSigDevToneEntry 2}

pktcSigDevToneFreqCounter OBJECT-TYPE
       SYNTAX       Unsigned32(1..8)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
           "This MIB object represents the number of consecutive
           multi-frequency tones for the particular tone type in
           the multi-frequency table (pktcSigDevMultiFreqToneTable).

           Such a sequence of the consecutive multi-frequency tones
           forms the tone group for the particular tone type in the
           pktcSigDevToneTable."
       ::={ pktcSigDevToneEntry 3}

pktcSigDevToneWholeToneRepeatCount      OBJECT-TYPE
    SYNTAX       Unsigned32 (0..5000)
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "This is the repeat count, which signifies how many times
         to repeat the entire on-off cadence sequence.  Setting this
         object may result in a cadence duration longer or shorter
         than the overall signal duration specified by the time out
         (TO) object for a particular signal.  If the repeat count
         results in a longer tone duration than the signal duration
         specified by the TO, the tone duration defined by the
         TO object for a particular signal always represents
         the overall signal duration for a tone.  In this case, the
         tone duration repeat count will not be fully exercised, and
         the desired tone duration will be truncated per the TO
         setting.  If the repeat count results in a shorter tone
         duration than the signal duration specified by the TO, the
         tone duration defined by the repeat count takes precedence
         over the TO and will end the signal event.  In this case,
Top   ToC   RFC5098 - Page 38
         the TO represents a time not to be exceeded for the signal.
         It is recommended to ensure proper telephony signaling so that
         the TO duration setting should always be longer than the
         desired repeat count-time duration."
    ::={ pktcSigDevToneEntry 4 }

pktcSigDevToneSteady    OBJECT-TYPE
    SYNTAX       TruthValue
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "This MIB object represents the steady tone status.  A value
         of 'true(1)' indicates that the steady tone is applied, and
         a value of 'false(2)' indicates otherwise.
         Devices must play out the on-off cadence sequence for
         the number of times indicated by the MIB object
         'pktcSigDevToneWholeToneRepeatCount' prior to applying the
         last tone steadily, indefinitely.  If the MIB table
         'pktcSigDevToneTable' contains multiple rows with this
         Object set to a value of 'true(1)', the steady tone is
         applied to the last repeating frequency group of the tone.

         Setting this MIB object may result in a tone duration that is
         longer or shorter than the overall signal duration
         specified by the time out (TO) MIB object for a particular
         signal.  If the repeat count results in a longer tone
         duration than the signal duration specified by the TO, the
         tone duration defined by the TO object for a particular
         signal always represents the overall signal duration for a
         tone.  In this case, the tone duration repeat count will
         not be fully exercised, and the desired tone duration will
         be truncated per the TO setting.  If the repeat count
         results in a shorter tone duration than the signal duration
         specified by the TO, the tone duration defined by the
         repeat count takes precedence over the TO and will end the
         signal event.  In this case, the TO represents a time not to
         be exceeded for the signal.

         It is recommended to ensure proper telephony signaling that
         The TO duration setting should always be longer than the
         desired repeat count-time duration, plus the desired maximum
         steady tone period."
    ::={ pktcSigDevToneEntry 5 }

   pktcSigDevMultiFreqToneTable    OBJECT-TYPE
       SYNTAX       SEQUENCE OF PktcSigDevMultiFreqToneEntry
       MAX-ACCESS   not-accessible
       STATUS       current
Top   ToC   RFC5098 - Page 39
       DESCRIPTION
           " This MIB table defines the characteristics of tones
             with multiple frequencies.  The constraints imposed
             on the tones by the MIB table pktcSigDevToneTable
             need to be considered for MIB objects in this table
             as well.

             The MTA MUST populate the corresponding row(s)
             of the pktcSigDevMultiFreqToneTable for each tone
             defined in the pktcSigDevToneTable.

             The contents of the table may be provisioned via
             MTA configuration."
       REFERENCE
           "PacketCable NCS Specification, ETSI-TS-101-909-4
            Specification."
       ::= { pktcSigDevObjects 33 }

   pktcSigDevMultiFreqToneEntry    OBJECT-TYPE
       SYNTAX       PktcSigDevMultiFreqToneEntry
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION
           " The different tone types with multiple frequencies
             that can be provisioned based on country-specific
             needs."
       INDEX {pktcSigDevToneType, pktcSigDevToneNumber}
       ::= { pktcSigDevMultiFreqToneTable 1 }

   PktcSigDevMultiFreqToneEntry ::= SEQUENCE {
         pktcSigDevToneNumber                    Unsigned32,
         pktcSigDevToneFirstFreqValue            Unsigned32,
         pktcSigDevToneSecondFreqValue           Unsigned32,
         pktcSigDevToneThirdFreqValue            Unsigned32,
         pktcSigDevToneFourthFreqValue           Unsigned32,
         pktcSigDevToneFreqMode                  INTEGER,
         pktcSigDevToneFreqAmpModePrtg           Unsigned32,
         pktcSigDevToneDbLevel                   TenthdBm,
         pktcSigDevToneFreqOnDuration            Unsigned32,
         pktcSigDevToneFreqOffDuration           Unsigned32,
         pktcSigDevToneFreqRepeatCount           Unsigned32
   }

   pktcSigDevToneNumber OBJECT-TYPE
       SYNTAX       Unsigned32(1..8)
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION
Top   ToC   RFC5098 - Page 40
          "This MIB object represents the frequency reference
           of a multi-frequency tone."
       ::={ pktcSigDevMultiFreqToneEntry 1}

   pktcSigDevToneFirstFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the first
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 2}

   pktcSigDevToneSecondFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the second
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 3}

   pktcSigDevToneThirdFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the third
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 4}

   pktcSigDevToneFourthFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the fourth
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 5}

   pktcSigDevToneFreqMode OBJECT-TYPE
       SYNTAX       INTEGER {
                     firstModulatedBySecond(1),
                     summation(2)
Top   ToC   RFC5098 - Page 41
                    }
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
       "This MIB object provides directive on the
        modulation or summation of the frequencies
        involved in the tone.

        It is to be noted that while summation can
        be done without any constraint on the number
        of frequencies, the modulation (amplitude)
        holds good only when there are two frequencies
        (first and second).

        Thus:
          - If the mode is set to a value of
            'firstModulatedBySecond(1)', the first frequency
            MUST be modulated by the second, and the remaining
            frequencies (third and fourth) ignored.  The
            percentage of amplitude modulation to be applied
            is defined by the MIB object
            pktcSigDevToneFreqAmpModePrtg.

          - If the mode is set to a value of
            'summation(2)', all the frequencies MUST be
            summed without any modulation.
       "
       ::={ pktcSigDevMultiFreqToneEntry 6}

  pktcSigDevToneFreqAmpModePrtg OBJECT-TYPE
       SYNTAX       Unsigned32(0..100)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
          "This MIB object represents the percentage of amplitude
           modulation applied to the second frequency
           when the MIB object pktcSigDevToneFreqMode is
           set to a value of 'firstModulatedBySecond (1)'.

           If the MIB object pktcSigDevToneFreqMode is set to
           value of 'summation (2)', then this MIB object MUST be
           ignored."
       ::={ pktcSigDevMultiFreqToneEntry 7}

  pktcSigDevToneDbLevel    OBJECT-TYPE
      SYNTAX       TenthdBm (-250..-110)
      UNITS        "1/10 of a dBm"
      MAX-ACCESS   read-only
Top   ToC   RFC5098 - Page 42
      STATUS       current
      DESCRIPTION
          "This MIB object contains the decibel level for each
           analog signal (tone) that is locally generated
           (versus in-band supervisory tones) and sourced to
           the a-b terminals (TE connection point).  Each tone
           in itself may consist of multiple frequencies, as
           defined by the MIB table pktcSigDevMultiFreqToneTable.

           This MIB object reflects the desired level at
           the Telco (POTS) a-b (T/R) terminals, including the
           effect of any MTA receiver gain (loss).  This is required
           so that locally generated tones are consistent with
           remotely generated in-band tones at the a-b terminals,
           consistent with user expectations.

           This MIB object must be set for each tone.
           When tones are formed by combining multi-frequencies,
           the level of each frequency shall be set so as to result
           in the tone level specified in this object at the a-b
           (T/R) terminals.

           The wide range of levels for this Object is required
           to provide signal-generator levels across the wide
           range of gains (losses) -- but does not imply the entire
           range is to be achievable given the range of gains (losses)
           in the MTA."
    DEFVAL { -120 }
    ::={ pktcSigDevMultiFreqToneEntry 8}

   pktcSigDevToneFreqOnDuration OBJECT-TYPE
       SYNTAX       Unsigned32(0..5000)
       UNITS        "milliseconds"
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
          "This MIB object represents the duration for which the
           frequency reference corresponding to the tone type
           is turned on."
       ::={ pktcSigDevMultiFreqToneEntry 9}

   pktcSigDevToneFreqOffDuration OBJECT-TYPE
       SYNTAX       Unsigned32(0..5000)
       UNITS        "milliseconds"
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
          "This MIB object represents the duration for which the
Top   ToC   RFC5098 - Page 43
           frequency reference corresponding to the tone type
           is turned off."
       ::={ pktcSigDevMultiFreqToneEntry 10}

   pktcSigDevToneFreqRepeatCount OBJECT-TYPE
       SYNTAX       Unsigned32(0..5000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
       "This MIB object indicates the number of times
       to repeat the cadence cycle represented by the
       on/off durations (refer to the MIB objects
       pktcSigDevToneFreqOnDuration and
       pktcSigDevToneFreqOffDuration).

       Setting this object may result in a tone duration that is
       longer or shorter than the overall signal duration
       specified by the time out (TO) object for the
       corresponding tone type.  If the value of this MIB
       Object indicates a longer duration than that
       specified by the TO, the latter overrules the former,
       and the desired tone duration will be truncated according
       to the TO.

       However, if the repeat count results in a shorter
       tone duration than the signal duration specified by
       the TO, the tone duration defined by the repeat count
       takes precedence over the TO and will end the signal
       event.  In this case, the TO represents a time not to
       be exceeded for the signal.  It is recommended, to
       ensure proper telephony signaling, that the TO
       duration setting should always be longer than the
       desired repeat count-time duration.  A value of zero
       means the tone sequence is to be played once but not
       repeated."
       ::={ pktcSigDevMultiFreqToneEntry 11}

   pktcSigDevCidDelayAfterLR  OBJECT-TYPE
       SYNTAX       Unsigned32 (300..800)
       UNITS        "Milliseconds"
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object specifies the delay between the end of the
            Line Reversal and the start of the FSK or DTMF signal.
            This MIB object is used only when pktcSigDevCidMode is
            set to a value of 'lrETS'.  This timing has a range of
            300 to 800 ms.
Top   ToC   RFC5098 - Page 44
            The following table defines the default values
            for this MIB object, depending on the signal type
           (pktcSigDevCidMode), and MUST be followed:

          Value of pktcSigDevCidMode       Default value

            duringringingETS               any value  (not used)
            dtAsETS                        any value  (not used)
            rpAsETS                        any value  (not used)
            lrAsETS                        any value  (not used)
            lrETS                          400

            An attempt to set this object while the value of
            pktcSigDevCidMode is not set to a value of 'lrETS' will
            result in an 'inconsistentValue' error.

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       DEFVAL { 400 }
       ::= {pktcSigDevObjects 34 }

   pktcSigDevCidDtmfStartCode OBJECT-TYPE
       SYNTAX       DtmfCode
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object identifies optional start codes used when
            the MIB object pktcSigDevCidSigProtocol is set
            to a value of 'dtmf(2)'.

            Different countries define different caller id signaling
            codes to support caller identification.  When Dual-Tone
            Multi-Frequency (DTMF) is used, the caller id digits are
            preceded by a 'start code' digit, followed by the digit
            transmission sequence <S1>...<Sn> (where Sx represents
            the digits 0-9), and terminated by the 'end code' digit.

            For example,
              <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.
            The start code for calling number delivery may be DTMF
            'A' or 'D'.  The start code for redirecting a number may be
            DTMF 'D'.  The DTMF code 'B' may be sent by the network
            as a start code for the transfer of information values,
            through which special events can be indicated to the
            user.  In some countries, the '*' or '#' may be used
            instead of 'A', 'B', 'C', or 'D'.

            The value of this MIB object MUST NOT persist across MTA
Top   ToC   RFC5098 - Page 45
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeA}
   ::= { pktcSigDevObjects 35 }

   pktcSigDevCidDtmfEndCode OBJECT-TYPE
       SYNTAX       DtmfCode
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object identifies optional end codes used when the
            pktcSigDevCidSigProtocol is set to a value of
            'dtmf(2)'.

            Different countries define different caller id signaling
            protocols to support caller identification.  When
            Dual-Tone Multi-Frequency (DTMF) is used, the caller id
            digits are preceded by a 'start code' digit, followed by
            the digit transmission sequence <S1>...<Sn> (where Sx
            represents the digits 0-9), and terminated by the 'end
            code' digit.

            For example,
              <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.

            The DTMF code 'C' may be sent by the network as an
            end code for the transfer of information values, through
            which special events can be indicated to the user.  In
            some countries, the '*' or '#' may be used instead of
            'A', 'B', 'C', or 'D'.

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeC}
   ::= { pktcSigDevObjects 36 }

   pktcSigDevVmwiSigProtocol  OBJECT-TYPE
       SYNTAX       PktcSubscriberSideSigProtocol
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object identifies the subscriber line protocol used
            for signaling the information on Visual Message Waiting
            Indicator (VMWI).  Different countries define different
            VMWI signaling protocols to support VMWI service.
Top   ToC   RFC5098 - Page 46
            Frequency shift keying (FSK) is most commonly used.
            DTMF is an alternative.

            The value of this MIB object MUST NOT persist across MTA
            reboots."
        DEFVAL { fsk }
   ::= { pktcSigDevObjects 37 }

   pktcSigDevVmwiDelayAfterLR    OBJECT-TYPE
       SYNTAX       Unsigned32 (0|300..800)
       UNITS        "Milliseconds"
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object specifies the delay between the end of the
            Line Reversal and the start of the FSK or DTMF signal.
            This object is only used when pktcSigDevVmwiMode is
            set to a value of 'lrETS'.
            This timing has a range of 300 to 800 ms.

            The following table defines the default values
            for this MIB object, depending on the signal type
           (pktcSigDevVmwiMode), and MUST be followed:

            Value of pktcSigDevVmwiMode       Default value

            duringringingETS                  any value  (not used)
            dtAsETS                           any value  (not used)
            rpAsETS                           any value  (not used)
            lrAsETS                           any value  (not used)
            lrETS                             400

            An attempt to set this object while the value of
            pktcSigDevVmwiMode is not 'lrETS' will result in an
            'inconsistentValue' error.

            The value of this MIB object MUST NOT persist across MTA
            reboots."

       DEFVAL {400}
           ::= {pktcSigDevObjects 38 }

   pktcSigDevVmwiDtmfStartCode OBJECT-TYPE
       SYNTAX       DtmfCode
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object identifies optional start codes used when
Top   ToC   RFC5098 - Page 47
            the pktcSigDevVmwiSigProtocol is set to a value of
            'dtmf(2)'.  Different countries define different On Hook
            Data Transmission Protocol signaling codes to support
            VMWI.

            When Dual-Tone Multi-Frequency (DTMF) is used, the VMWI
            digits are preceded by a 'start code' digit, followed
            by the digit transmission sequence <S1>...<Sn> (where
            Sx represents the digits 0-9), and terminated by the 'end
            code' digit.

            For example,
              <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.

            The start code for redirecting VMWI may be DTMF 'D'
            The DTMF code 'B' may be sent by the network as a start
            code for the transfer of information values, through
            which special events can be indicated to the user.  In
            some countries, the '*' or '#' may be used instead of
            'A', 'B', 'C', or 'D'.

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeA}
   ::= { pktcSigDevObjects 39 }

   pktcSigDevVmwiDtmfEndCode OBJECT-TYPE
       SYNTAX       DtmfCode
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           "This object identifies an optional end code used when the
            pktcSigDevVmwiSigProtocol is set to a value of
            'dtmf(2)'.  Different countries define different on-hook
            Data Transmission Protocol signaling codes to support
            VMWI.

            When Dual-Tone Multi-Frequency (DTMF) is used, the VMWI
            digits are preceded by a 'start code' digit, followed
            by the digit transmission sequence <S1>...<Sn> (where
            Sx represents the digits 0-9), and terminated by the 'end
            code' digit.

            For example,
              <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.
Top   ToC   RFC5098 - Page 48
            The DTMF code 'C' may be sent by the network as an end code
            for the transfer of information values, through which
            special events can be indicated to the user.  In some
            countries, the '*' or '#' may be used instead of 'A',
            'B', 'C', or 'D'.

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeC}
   ::= { pktcSigDevObjects 40 }

pktcSigDevrpAsDtsDuration     OBJECT-TYPE
       SYNTAX       Unsigned32 (0|200..500)
       UNITS        "Milliseconds"
       MAX-ACCESS   read-write
       STATUS       current
       DESCRIPTION
           " This object specifies the duration of the rpASDTS ring
             pulse prior to the start of the transmission of the
             FSK or DTMF containing the caller id information.  It is
             only used when pktcSigDevCidMode is set to a value of
             'rpAsETS'.

             The following table defines the default values
             for this MIB object, depending on the signal type
            (pktcSigDevCidMode), and MUST be followed:

             Value of pktcSigDevCidMode       Default value

             duringringingETS                 any value  (not used)
             dtAsETS                          any value  (not used)
             rpAsETS                          250
             lrAsETS                          any value  (not used)
             lrETS                            any value  (not used)

             An attempt to set this object while the value of
             pktcSigDevCidMode is not 'rpAsETS' will result in
             an 'inconsistentValue' error.

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
           "ETSI-EN-300-659-1 Specification and Belgacom
            BGC_D_48_9811_30_09_EDOC version 3.3"
       DEFVAL { 250 }
       ::= {pktcSigDevObjects 41 }


(next page on part 3)

Next Section