6. MIB Definition
The following MIB Module imports from: [RFC2578], [RFC2579], [RFC2580], [RFC2863], [RFC3289], [RFC3411], and [RFC4001]. It also uses definitions from [RFC1108], [RFC3060], and [RFC3629]. IPSEC-SPD-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32, mib-2 FROM SNMPv2-SMI -- [RFC2578] TEXTUAL-CONVENTION, RowStatus, TruthValue, TimeStamp, StorageType, VariablePointer FROM SNMPv2-TC -- [RFC2579]
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] InterfaceIndex FROM IF-MIB -- [RFC2863] diffServMIBMultiFieldClfrGroup, IfDirection, diffServMultiFieldClfrNextFree FROM DIFFSERV-MIB -- [RFC3289] InetAddressType, InetAddress FROM INET-ADDRESS-MIB -- [RFC4001] SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- [RFC3411] ; -- -- module identity -- spdMIB MODULE-IDENTITY LAST-UPDATED "200702070000Z" -- 7 February 2007 ORGANIZATION "IETF IP Security Policy Working Group" CONTACT-INFO "Michael Baer P.O. Box 72682 Davis, CA 95617 Phone: +1 530 902 3131 Email: baerm@tislabs.com Ricky Charlet Email: rcharlet@alumni.calpoly.edu Wes Hardaker Sparta, Inc. P.O. Box 382 Davis, CA 95617 Phone: +1 530 792 1913 Email: hardaker@tislabs.com Robert Story Revelstone Software PO Box 1812
Tucker, GA 30085 Phone: +1 770 617 3722 Email: rstory@ipsp.revelstone.com Cliff Wang ARO 4300 S. Miami Blvd. Durham, NC 27703 E-Mail: cliffwangmail@yahoo.com" DESCRIPTION "This MIB module defines configuration objects for managing IPsec Security Policies. In general, this MIB can be implemented anywhere IPsec security services exist (e.g., bump-in-the-wire, host, gateway, firewall, router, etc.). Copyright (C) The IETF Trust (2007). This version of this MIB module is part of RFC 4807; see the RFC itself for full legal notices." -- Revision History REVISION "200702070000Z" -- 7 February 2007 DESCRIPTION "Initial version, published as RFC 4807." ::= { mib-2 153 } -- -- groups of related objects -- spdConfigObjects OBJECT IDENTIFIER ::= { spdMIB 1 } spdNotificationObjects OBJECT IDENTIFIER ::= { spdMIB 2 } spdConformanceObjects OBJECT IDENTIFIER ::= { spdMIB 3 } spdActions OBJECT IDENTIFIER ::= { spdMIB 4 } -- -- Textual Conventions -- SpdBooleanOperator ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The SpdBooleanOperator operator is used to specify whether sub-components in a decision-making process are
ANDed or ORed together to decide if the resulting expression is true or false." SYNTAX INTEGER { or(1), and(2) } SpdAdminStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The SpdAdminStatus is used to specify the administrative status of an object. Objects that are disabled MUST NOT be used by the packet processing engine." SYNTAX INTEGER { enabled(1), disabled(2) } SpdIPPacketLogging ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "SpdIPPacketLogging specifies whether an audit message SHOULD be logged if a packet is passed through a Security Association (SA) and if some of that packet is included in the log event. A value of '-1' indicates no logging. A value of '0' or greater indicates that logging SHOULD be done and indicates the number of bytes starting at the beginning of the packet to place in the log. Values greater than the size of the packet being processed indicate that the entire packet SHOULD be sent. Examples: '-1' no logging '0' log but do not include any of the packet in the log '20' log and include the first 20 bytes of the packet in the log." SYNTAX Integer32 (-1..65535) SpdTimePeriod ::= TEXTUAL-CONVENTION DISPLAY-HINT "31t" STATUS current DESCRIPTION "This property identifies an overall range of calendar dates and time. In a boolean context, a value within this time range, inclusive, is considered true. This information is encoded as an octet string using the UTF-8 transformation format described in STD 63, RFC 3629. It uses the format suggested in RFC 3060. An octet string
represents a start date and time and an end date and time. For example: yyyymmddThhmmss/yyyymmddThhmmss Where: yyyy = year mm = month dd = day hh = hour mm = minute ss = second The first 'yyyymmddThhmmss' sub-string indicates the start date and time. The second 'yyyymmddThhmmss' sub-string indicates the end date and time. The character 'T' within these sub-strings indicates the beginning of the time portion of each sub-string. The solidus character '/' separates the start from the end date and time. The end date and time MUST be subsequent to the start date and time. There are also two allowed substitutes for a 'yyyymmddThhmmss' sub-string: one for the start date and time, and one for the end date and time. If the start date and time are replaced with the string 'THISANDPRIOR', this sub-string would indicate the current date and time and the previous dates and time. If the end date and time are replaced with the string 'THISANDFUTURE', this sub-string would indicate the current date and time and the subsequent dates and time. Any of the following SHOULD be considered a 'wrongValue' error: - Setting a value with the end date and time earlier than or equal to the start date and time. - Setting the start date and time to 'THISANDFUTURE'. - Setting the end date and time to 'THISANDPRIOR'." REFERENCE "RFC 3060, 3269" SYNTAX OCTET STRING (SIZE (0..31)) -- -- Policy group definitions -- spdLocalConfigObjects OBJECT IDENTIFIER ::= { spdConfigObjects 1 } spdIngressPolicyGroupName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-write STATUS current
DESCRIPTION "This object indicates the global system policy group that is to be applied on ingress packets (i.e., arriving at an interface from a network) when a given endpoint does not contain a policy definition in the spdEndpointToGroupTable. Its value can be used as an index into the spdGroupContentsTable to retrieve a list of policies. A zero length string indicates that no system-wide policy exists and the default policy of 'drop' SHOULD be executed for ingress packets until one is imposed by either this object or by the endpoint processing a given packet. This object MUST be persistent" DEFVAL { "" } ::= { spdLocalConfigObjects 1 } spdEgressPolicyGroupName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the policy group containing the global system policy that is to be applied on egress packets (i.e., packets leaving an interface and entering a network) when a given endpoint does not contain a policy definition in the spdEndpointToGroupTable. Its value can be used as an index into the spdGroupContentsTable to retrieve a list of policies. A zero length string indicates that no system-wide policy exists and the default policy of 'drop' SHOULD be executed for egress packets until one is imposed by either this object or by the endpoint processing a given packet. This object MUST be persistent" DEFVAL { "" } ::= { spdLocalConfigObjects 2 } spdEndpointToGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdEndpointToGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maps policies (groupings) onto an endpoint (interface). A policy group assigned to an endpoint is then used to control access to the network traffic passing through that endpoint.
If an endpoint has been configured with a policy group and no rule within that policy group matches that packet, the default action in this case SHALL be to drop the packet. If no policy group has been assigned to an endpoint, then the policy group specified by spdIngressPolicyGroupName MUST be used on traffic inbound from the network through that endpoint, and the policy group specified by spdEgressPolicyGroupName MUST be used for traffic outbound to the network through that endpoint." ::= { spdConfigObjects 2 } spdEndpointToGroupEntry OBJECT-TYPE SYNTAX SpdEndpointToGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A mapping assigning a policy group to an endpoint." INDEX { spdEndGroupDirection, spdEndGroupInterface } ::= { spdEndpointToGroupTable 1 } SpdEndpointToGroupEntry ::= SEQUENCE { spdEndGroupDirection IfDirection, spdEndGroupInterface InterfaceIndex, spdEndGroupName SnmpAdminString, spdEndGroupLastChanged TimeStamp, spdEndGroupStorageType StorageType, spdEndGroupRowStatus RowStatus } spdEndGroupDirection OBJECT-TYPE SYNTAX IfDirection MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates which direction of packets crossing the interface are associated with which spdEndGroupName object. Ingress packets, or packets into the device match when this value is inbound(1). Egress packets or packets out of the device match when this value is outbound(2)." ::= { spdEndpointToGroupEntry 1 } spdEndGroupInterface OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION
"This value matches the IF-MIB's ifTable's ifIndex column and indicates the interface associated with a given endpoint. This object can be used to uniquely identify an endpoint that a set of policy groups are applied to." ::= { spdEndpointToGroupEntry 2 } spdEndGroupName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "The policy group name to apply at this endpoint. The value of the spdEndGroupName object is then used as an index into the spdGroupContentsTable to come up with a list of rules that MUST be applied at this endpoint." ::= { spdEndpointToGroupEntry 3 } spdEndGroupLastChanged OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means. If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdEndpointToGroupEntry 4 } spdEndGroupStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable." DEFVAL { nonVolatile } ::= { spdEndpointToGroupEntry 5 } spdEndGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create
STATUS current DESCRIPTION "This object indicates the conceptual status of this row. The value of this object has no effect on whether other objects in this conceptual row can be modified. This object is considered 'notReady' and MUST NOT be set to active until one or more active rows exist within the spdGroupContentsTable for the group referenced by the spdEndGroupName object." ::= { spdEndpointToGroupEntry 6 } -- -- policy group definition table -- spdGroupContentsTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdGroupContentsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of rules and/or subgroups contained within a given policy group. For a given value of spdGroupContName, the set of rows sharing that value forms a 'group'. The rows in a group MUST be processed according to the value of the spdGroupContPriority object in each row. The processing MUST be executed starting with the lowest value of spdGroupContPriority and in ascending order thereafter. If an action is executed as the result of the processing of a row in a group, the processing of further rows in that group MUST stop. Iterating to the next policy group row by finding the next largest spdGroupContPriority object SHALL only be done if no actions were run while processing the current row for a given packet." ::= { spdConfigObjects 3 } spdGroupContentsEntry OBJECT-TYPE SYNTAX SpdGroupContentsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines a given sub-component within a policy group. A sub-component is either a rule or another group as indicated by spdGroupContComponentType and referenced by spdGroupContComponentName."
INDEX { spdGroupContName, spdGroupContPriority } ::= { spdGroupContentsTable 1 } SpdGroupContentsEntry ::= SEQUENCE { spdGroupContName SnmpAdminString, spdGroupContPriority Integer32, spdGroupContFilter VariablePointer, spdGroupContComponentType INTEGER, spdGroupContComponentName SnmpAdminString, spdGroupContLastChanged TimeStamp, spdGroupContStorageType StorageType, spdGroupContRowStatus RowStatus } spdGroupContName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The administrative name of the group associated with this row. A 'group' is formed by all the rows in this table that have the same value of this object." ::= { spdGroupContentsEntry 1 } spdGroupContPriority OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The priority (sequence number) of the sub-component in a group that this row represents. This value indicates the order that each row of this table MUST be processed from low to high. For example, a row with a priority of 0 is processed before a row with a priority of 1, a 1 before a 2, etc." ::= { spdGroupContentsEntry 2 } spdGroupContFilter OBJECT-TYPE SYNTAX VariablePointer MAX-ACCESS read-create STATUS current DESCRIPTION "spdGroupContFilter points to a filter that is evaluated to determine whether the spdGroupContComponentName within this row is exercised. Managers can use this object to classify groups of rules, or subgroups, together in order to achieve a greater degree of control and optimization over the execution order of the items within the group. If the
filter evaluates to false, the rule or subgroup will be skipped and the next rule or subgroup will be evaluated instead. This value can be used to indicate a scalar or row in a table. When indicating a row in a table, this value MUST point to the first column instance in that row. An example usage of this object would be to limit a group of rules to executing only when the IP packet being processed is designated to be processed by IKE. This effectively creates a group of IKE-specific rules. The following tables and scalars can be pointed to by this column. All but diffServMultiFieldClfrTable are defined in this MIB: diffServMultiFieldClfrTable spdIpOffsetFilterTable spdTimeFilterTable spdCompoundFilterTable spdTrueFilter spdIpsoHeaderFilterTable Implementations MAY choose to provide support for other filter tables or scalars. If this column is set to a VariablePointer value, which references a non-existent row in an otherwise supported table, the inconsistentName exception MUST be returned. If the table or scalar pointed to by the VariablePointer is not supported at all, then an inconsistentValue exception MUST be returned. If, during packet processing, a row in this table is applied to a packet and the value of this column in that row references a non-existent or non-supported object, the packet MUST be dropped." REFERENCE "RFC 3289" DEFVAL { spdTrueFilterInstance } ::= { spdGroupContentsEntry 3 } spdGroupContComponentType OBJECT-TYPE SYNTAX INTEGER { group(1), rule(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether the spdGroupContComponentName object is the name of another group defined within the spdGroupContentsTable or is the name of a rule defined
within the spdRuleDefinitionTable." DEFVAL { rule } ::= { spdGroupContentsEntry 4 } spdGroupContComponentName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the policy rule or subgroup contained within this row, as indicated by the spdGroupContComponentType object." ::= { spdGroupContentsEntry 5 } spdGroupContLastChanged OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means. If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdGroupContentsEntry 6 } spdGroupContStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable." DEFVAL { nonVolatile } ::= { spdGroupContentsEntry 7 } spdGroupContRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the conceptual status of this row.
The value of this object has no effect on whether other objects in this conceptual row can be modified. This object MUST NOT be set to active until the row to which the spdGroupContComponentName points to exists and is active. If active, this object MUST remain active unless one of the following two conditions are met: I. No active row in spdEndpointToGroupTable exists that references this row's group (i.e., indicate this row's spdGroupContName). II. Or at least one other active row in this table has a matching spdGroupContName. If neither condition is met, an attempt to set this row to something other than active MUST result in an inconsistentValue error." ::= { spdGroupContentsEntry 8 } -- -- policy definition table -- spdRuleDefinitionTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdRuleDefinitionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines a rule by associating a filter or a set of filters to an action to be executed." ::= { spdConfigObjects 4 } spdRuleDefinitionEntry OBJECT-TYPE SYNTAX SpdRuleDefinitionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row defining a particular rule definition. A rule definition binds a filter pointer to an action pointer." INDEX { spdRuleDefName } ::= { spdRuleDefinitionTable 1 } SpdRuleDefinitionEntry ::= SEQUENCE { spdRuleDefName SnmpAdminString,
spdRuleDefDescription SnmpAdminString, spdRuleDefFilter VariablePointer, spdRuleDefFilterNegated TruthValue, spdRuleDefAction VariablePointer, spdRuleDefAdminStatus SpdAdminStatus, spdRuleDefLastChanged TimeStamp, spdRuleDefStorageType StorageType, spdRuleDefRowStatus RowStatus } spdRuleDefName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "spdRuleDefName is the administratively assigned name of the rule referred to by the spdGroupContComponentName object." ::= { spdRuleDefinitionEntry 1 } spdRuleDefDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "A user defined string. This field MAY be used for administrative tracking purposes." DEFVAL { "" } ::= { spdRuleDefinitionEntry 2 } spdRuleDefFilter OBJECT-TYPE SYNTAX VariablePointer MAX-ACCESS read-create STATUS current DESCRIPTION "spdRuleDefFilter points to a filter that is used to evaluate whether the action associated with this row is executed or not. The action will only execute if the filter referenced by this object evaluates to TRUE after first applying any negation required by the spdRuleDefFilterNegated object. The following tables and scalars can be pointed to by this column. All but diffServMultiFieldClfrTable are defined in this MIB. Implementations MAY choose to provide support for other filter tables or scalars as well: diffServMultiFieldClfrTable
spdIpOffsetFilterTable spdTimeFilterTable spdCompoundFilterTable spdTrueFilter If this column is set to a VariablePointer value, which references a non-existent row in an otherwise supported table, the inconsistentName exception MUST be returned. If the table or scalar pointed to by the VariablePointer is not supported at all, then an inconsistentValue exception MUST be returned. If, during packet processing, this column has a value that references a non-existent or non-supported object, the packet MUST be dropped." REFERENCE "RFC 3289" ::= { spdRuleDefinitionEntry 3 } spdRuleDefFilterNegated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "spdRuleDefFilterNegated specifies whether or not the results of the filter referenced by the spdRuleDefFilter object is negated." DEFVAL { false } ::= { spdRuleDefinitionEntry 4 } spdRuleDefAction OBJECT-TYPE SYNTAX VariablePointer MAX-ACCESS read-create STATUS current DESCRIPTION "This column points to the action to be taken. It MAY, but is not limited to, point to a row in one of the following tables: spdCompoundActionTable ipsaSaPreconfiguredActionTable ipiaIkeActionTable ipiaIpsecActionTable It MAY also point to one of the scalar objects beneath spdStaticActions. If this object is set to a pointer to a row in an unsupported (or unknown) table, an inconsistentValue
error MUST be returned. If this object is set to point to a non-existent row in an otherwise supported table, an inconsistentName error MUST be returned. If, during packet processing, this column has a value that references a non-existent or non-supported object, the packet MUST be dropped." ::= { spdRuleDefinitionEntry 5 } spdRuleDefAdminStatus OBJECT-TYPE SYNTAX SpdAdminStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether the current rule definition is considered active. If the value is enabled, the rule MUST be evaluated when processing packets. If the value is disabled, the packet processing MUST continue as if this rule's filter had effectively failed." DEFVAL { enabled } ::= { spdRuleDefinitionEntry 6 } spdRuleDefLastChanged OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means. If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdRuleDefinitionEntry 7 } spdRuleDefStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have
to be writable." DEFVAL { nonVolatile } ::= { spdRuleDefinitionEntry 8 } spdRuleDefRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the conceptual status of this row. The value of this object has no effect on whether other objects in this conceptual row can be modified. This object MUST NOT be set to active until the containing conditions, filters, and actions have been defined. Once active, it MUST remain active until no active policyGroupContents entries are referencing it. A failed attempt to do so MUST return an inconsistentValue error." ::= { spdRuleDefinitionEntry 9 } -- -- Policy compound filter definition table -- spdCompoundFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdCompoundFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table defining compound filters and their associated parameters. A row in this table can be pointed to by a spdRuleDefFilter object." ::= { spdConfigObjects 5 } spdCompoundFilterEntry OBJECT-TYPE SYNTAX SpdCompoundFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the spdCompoundFilterTable. Each entry in this table represents a compound filter. A filter defined by this table is considered to have a TRUE return value if and only if: spdCompFiltLogicType is AND and all of the sub-filters associated with it, as defined in the spdSubfiltersTable, are all true themselves (after applying any required
negation, as defined by the ficFilterIsNegated object). spdCompFiltLogicType is OR and at least one of the sub-filters associated with it, as defined in the spdSubfiltersTable, is true itself (after applying any required negation, as defined by the ficFilterIsNegated object." INDEX { spdCompFiltName } ::= { spdCompoundFilterTable 1 } SpdCompoundFilterEntry ::= SEQUENCE { spdCompFiltName SnmpAdminString, spdCompFiltDescription SnmpAdminString, spdCompFiltLogicType SpdBooleanOperator, spdCompFiltLastChanged TimeStamp, spdCompFiltStorageType StorageType, spdCompFiltRowStatus RowStatus } spdCompFiltName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A user definable string. This value is used as an index into this table." ::= { spdCompoundFilterEntry 1 } spdCompFiltDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "A user definable string. This field MAY be used for your administrative tracking purposes." DEFVAL { "" } ::= { spdCompoundFilterEntry 2 } spdCompFiltLogicType OBJECT-TYPE SYNTAX SpdBooleanOperator MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether the sub-component filters of this compound filter are functionally ANDed or ORed together." DEFVAL { and } ::= { spdCompoundFilterEntry 3 }
spdCompFiltLastChanged OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means. If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdCompoundFilterEntry 4 } spdCompFiltStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable." DEFVAL { nonVolatile } ::= { spdCompoundFilterEntry 5 } spdCompFiltRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the conceptual status of this row. The value of this object has no effect on whether other objects in this conceptual row can be modified. Once active, it MUST NOT have its value changed if any active rows in the spdRuleDefinitionTable are currently pointing at this row." ::= { spdCompoundFilterEntry 6 } -- -- Policy filters in a cf table -- spdSubfiltersTable OBJECT-TYPE
SYNTAX SEQUENCE OF SpdSubfiltersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines a list of filters contained within a given compound filter defined in the spdCompoundFilterTable." ::= { spdConfigObjects 6 } spdSubfiltersEntry OBJECT-TYPE SYNTAX SpdSubfiltersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the spdSubfiltersTable. There is an entry in this table for each sub-filter of all compound filters present in the spdCompoundFilterTable." INDEX { spdCompFiltName, spdSubFiltPriority } ::= { spdSubfiltersTable 1 } SpdSubfiltersEntry ::= SEQUENCE { spdSubFiltPriority Integer32, spdSubFiltSubfilter VariablePointer, spdSubFiltSubfilterIsNegated TruthValue, spdSubFiltLastChanged TimeStamp, spdSubFiltStorageType StorageType, spdSubFiltRowStatus RowStatus } spdSubFiltPriority OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The priority of a given filter within a compound filter. The order of execution is from lowest to highest priority value (i.e., priority 0 before priority 1, 1 before 2, etc.). Implementations MAY choose to follow this ordering, as set by the manager that created the rows. This can allow a manager to intelligently construct filter lists such that faster filters are evaluated first." ::= { spdSubfiltersEntry 1 } spdSubFiltSubfilter OBJECT-TYPE SYNTAX VariablePointer MAX-ACCESS read-create STATUS current DESCRIPTION
"The OID of the contained filter. The value of this object is a VariablePointer that references the filter to be included in this compound filter. The following tables and scalars can be pointed to by this column. All but diffServMultiFieldClfrTable are defined in this MIB. Implementations MAY choose to provide support for other filter tables or scalars as well: diffServMultiFieldClfrTable spdIpsoHeaderFilterTable spdIpOffsetFilterTable spdTimeFilterTable spdCompoundFilterTable spdTrueFilter If this column is set to a VariablePointer value that references a non-existent row in an otherwise supported table, the inconsistentName exception MUST be returned. If the table or scalar pointed to by the VariablePointer is not supported at all, then an inconsistentValue exception MUST be returned. If, during packet processing, this column has a value that references a non-existent or non-supported object, the packet MUST be dropped." REFERENCE "RFC 3289" ::= { spdSubfiltersEntry 2 } spdSubFiltSubfilterIsNegated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether or not the result of applying this sub-filter is negated." DEFVAL { false } ::= { spdSubfiltersEntry 3 } spdSubFiltLastChanged OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means.
If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdSubfiltersEntry 4 } spdSubFiltStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable." DEFVAL { nonVolatile } ::= { spdSubfiltersEntry 5 } spdSubFiltRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the conceptual status of this row. The value of this object has no effect on whether other objects in this conceptual row can be modified. This object cannot be made active until a filter referenced by the spdSubFiltSubfilter object is both defined and active. An attempt to do so MUST result in an inconsistentValue error. If active, this object MUST remain active unless one of the following two conditions are met: I. No active row in the SpdCompoundFilterTable exists that has a matching spdCompFiltName. II. Or, at least one other active row in this table has a matching spdCompFiltName. If neither condition is met, an attempt to set this row to something other than active MUST result in an inconsistentValue error." ::= { spdSubfiltersEntry 6 }
-- -- Static Filters -- spdStaticFilters OBJECT IDENTIFIER ::= { spdConfigObjects 7 } spdTrueFilter OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "This scalar indicates a (automatic) true result for a filter. That is, this is a filter that is always true; it is useful for adding as a default filter for a default action or a set of actions." ::= { spdStaticFilters 1 } spdTrueFilterInstance OBJECT IDENTIFIER ::= { spdTrueFilter 0 } -- -- Policy IP Offset filter definition table -- spdIpOffsetFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdIpOffsetFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of filter definitions to be used within the spdRuleDefinitionTable or the spdSubfiltersTable. This type of filter is used to compare an administrator specified octet string to the octets at a particular location in a packet." ::= { spdConfigObjects 8 } spdIpOffsetFilterEntry OBJECT-TYPE SYNTAX SpdIpOffsetFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A definition of a particular filter." INDEX { spdIpOffFiltName } ::= { spdIpOffsetFilterTable 1 }
SpdIpOffsetFilterEntry ::= SEQUENCE { spdIpOffFiltName SnmpAdminString, spdIpOffFiltOffset Unsigned32, spdIpOffFiltType INTEGER, spdIpOffFiltValue OCTET STRING, spdIpOffFiltLastChanged TimeStamp, spdIpOffFiltStorageType StorageType, spdIpOffFiltRowStatus RowStatus } spdIpOffFiltName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The administrative name for this filter." ::= { spdIpOffsetFilterEntry 1 } spdIpOffFiltOffset OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the byte offset from the front of the entire IP packet where the value or arithmetic comparison is done. A value of '0' indicates the first byte of the packet header. If this value is greater than the length of the packet, the filter represented by this row should be considered to fail." ::= { spdIpOffsetFilterEntry 2 } spdIpOffFiltType OBJECT-TYPE SYNTAX INTEGER { equal(1), notEqual(2), arithmeticLess(3), arithmeticGreaterOrEqual(4), arithmeticGreater(5), arithmeticLessOrEqual(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "This defines the various tests that are used when evaluating a given filter. The various tests definable in this table are as follows: equal: - Tests if the OCTET STRING, 'spdIpOffFiltValue', matches
a value in the packet starting at the given offset in the packet and comparing the entire OCTET STRING of 'spdIpOffFiltValue'. Any values compared this way are assumed to be unsigned integer values in network byte order of the same length as 'spdIpOffFiltValue'. notEqual: - Tests if the OCTET STRING, 'spdIpOffFiltValue', does not match a value in the packet starting at the given offset in the packet and comparing to the entire OCTET STRING of 'spdIpOffFiltValue'. Any values compared this way are assumed to be unsigned integer values in network byte order of the same length as 'spdIpOffFiltValue'. arithmeticLess: - Tests if the OCTET STRING, 'spdIpOffFiltValue', is arithmetically less than ('<') the value starting at the given offset within the packet. The value in the packet is assumed to be an unsigned integer in network byte order of the same length as 'spdIpOffFiltValue'. arithmeticGreaterOrEqual: - Tests if the OCTET STRING, 'spdIpOffFiltValue', is arithmetically greater than or equal to ('>=') the value starting at the given offset within the packet. The value in the packet is assumed to be an unsigned integer in network byte order of the same length as 'spdIpOffFiltValue'. arithmeticGreater: - Tests if the OCTET STRING, 'spdIpOffFiltValue', is arithmetically greater than ('>') the value starting at the given offset within the packet. The value in the packet is assumed to be an unsigned integer in network byte order of the same length as 'spdIpOffFiltValue'. arithmeticLessOrEqual: - Tests if the OCTET STRING, 'spdIpOffFiltValue', is arithmetically less than or equal to ('<=') the value starting at the given offset within the packet. The value in the packet is assumed to be an unsigned integer in network byte order of the same length as 'spdIpOffFiltValue'." ::= { spdIpOffsetFilterEntry 3 } spdIpOffFiltValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..1024)) MAX-ACCESS read-create STATUS current DESCRIPTION "spdIpOffFiltValue is used for match comparisons of a packet at spdIpOffFiltOffset." ::= { spdIpOffsetFilterEntry 4 } spdIpOffFiltLastChanged OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means. If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdIpOffsetFilterEntry 5 } spdIpOffFiltStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable." DEFVAL { nonVolatile } ::= { spdIpOffsetFilterEntry 6 } spdIpOffFiltRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the conceptual status of this row. The value of this object has no effect on whether other objects in this conceptual row can be modified. If active, this object MUST remain active if it is
referenced by an active row in another table. An attempt to set it to anything other than active while it is referenced by an active row in another table MUST result in an inconsistentValue error." ::= { spdIpOffsetFilterEntry 7 } -- -- Time/scheduling filter table -- spdTimeFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdTimeFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines a table of filters that can be used to effectively enable or disable policies based on a valid time range." ::= { spdConfigObjects 9 } spdTimeFilterEntry OBJECT-TYPE SYNTAX SpdTimeFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row describing a given time frame for which a policy is filtered on to activate or deactivate the rule. If all the column objects in a row are true for the current time, the row evaluates as 'true'. More explicitly, the time matching column objects in a row MUST be logically ANDed together to form the boolean true/false for the row." INDEX { spdTimeFiltName } ::= { spdTimeFilterTable 1 } SpdTimeFilterEntry ::= SEQUENCE { spdTimeFiltName SnmpAdminString, spdTimeFiltPeriod SpdTimePeriod, spdTimeFiltMonthOfYearMask BITS, spdTimeFiltDayOfMonthMask OCTET STRING, spdTimeFiltDayOfWeekMask BITS, spdTimeFiltTimeOfDayMask SpdTimePeriod, spdTimeFiltLastChanged TimeStamp, spdTimeFiltStorageType StorageType, spdTimeFiltRowStatus RowStatus }
spdTimeFiltName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An administratively assigned name for this filter." ::= { spdTimeFilterEntry 1 } spdTimeFiltPeriod OBJECT-TYPE SYNTAX SpdTimePeriod MAX-ACCESS read-create STATUS current DESCRIPTION "The valid time period for this filter. This column is considered 'true' if the current time is within the range of this object." DEFVAL { "THISANDPRIOR/THISANDFUTURE" } ::= { spdTimeFilterEntry 2 } spdTimeFiltMonthOfYearMask OBJECT-TYPE SYNTAX BITS { january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11) } MAX-ACCESS read-create STATUS current DESCRIPTION "A bit mask that indicates acceptable months of the year. This column evaluates to 'true' if the current month's bit is set." DEFVAL { { january, february, march, april, may, june, july, august, september, october, november, december } } ::= { spdTimeFilterEntry 3 } spdTimeFiltDayOfMonthMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines which days of the month the current time is valid for. It is a sequence of 64 BITS, where each BIT represents a corresponding day of the month in forward or reverse order. Starting from the left-most bit, the first 31 bits identify the day of the month, counting from the beginning of the month. The following 31 bits (bits 32-62) indicate the day of the month, counting from the end of the
month. For months with fewer than 31 days, the bits that correspond to the non-existent days of that month are ignored (e.g., for non-leap year Februarys, bits 29-31 and 60-62 are ignored). This column evaluates to 'true' if the current day of the month's bit is set. For example, a value of 0X'80 00 00 01 00 00 00 00' indicates that this column evaluates to true on the first and last days of the month. The last two bits in the string MUST be zero." DEFVAL { 'fffffffffffffffe'H } ::= { spdTimeFilterEntry 4 } spdTimeFiltDayOfWeekMask OBJECT-TYPE SYNTAX BITS { sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "A bit mask that defines which days of the week that the current time is valid for. This column evaluates to 'true' if the current day of the week's bit is set." DEFVAL { { monday, tuesday, wednesday, thursday, friday, saturday, sunday } } ::= { spdTimeFilterEntry 5 } spdTimeFiltTimeOfDayMask OBJECT-TYPE SYNTAX SpdTimePeriod MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the start and end time of the day for which this filter evaluates to true. The date portions of the spdTimePeriod TC are ignored for purposes of evaluating this mask, and only the time-specific portions are used. This column evaluates to 'true' if the current time of day is within the range of the start and end times of the day indicated by this object." DEFVAL { "00000000T000000/00000000T240000" } ::= { spdTimeFilterEntry 6 } spdTimeFiltLastChanged OBJECT-TYPE SYNTAX TimeStamp
MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this row was last modified or created either through SNMP SETs or by some other external means. If this row has not been modified since the last re-initialization of the network management subsystem, this object SHOULD have a zero value." ::= { spdTimeFilterEntry 7 } spdTimeFiltStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process MAY have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable." DEFVAL { nonVolatile } ::= { spdTimeFilterEntry 8 } spdTimeFiltRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the conceptual status of this row. The value of this object has no effect on whether other objects in this conceptual row can be modified. If active, this object MUST remain active if it is referenced by an active row in another table. An attempt to set it to anything other than active while it is referenced by an active row in another table MUST result in an inconsistentValue error." ::= { spdTimeFilterEntry 9 } -- -- IPSO protection authority filtering --