Tech-invite3GPPspaceIETFspace
96959493929190898887868584838281807978777675747372717069686766656463626160595857565554535251504948474645444342414039383736353433323130292827262524232221201918171615141312111009080706050403020100
in Index   Prev   Next

RFC 4133

Entity MIB (Version 3)

Pages: 62
Obsoletes:  2737
Obsoleted by:  6933
Part 3 of 3 – Pages 44 to 62
First   Prev   None

ToP   noToC   RFC4133 - Page 44   prevText

4. Usage Examples

The following sections iterate the instance values for two example networking devices. These examples are kept simple to make them more understandable. Auxiliary components such as fans, sensors, empty slots, and sub-modules are not shown, but might be modeled in real implementations.

4.1. Router/Bridge

The first example is a router containing two slots. Each slot contains a 3 port router/bridge module. Each port is represented in the ifTable. There are two logical instances of OSPF running and two logical bridges: Physical entities -- entPhysicalTable: 1 Field-replaceable physical chassis: entPhysicalDescr.1 == 'Acme Chassis Model 100' entPhysicalVendorType.1 == acmeProducts.chassisTypes.1 entPhysicalContainedIn.1 == 0 entPhysicalClass.1 == chassis(3) entPhysicalParentRelPos.1 == 0 entPhysicalName.1 == '100-A' entPhysicalHardwareRev.1 == 'A(1.00.02)' entPhysicalSoftwareRev.1 == '' entPhysicalFirmwareRev.1 == '' entPhysicalSerialNum.1 == 'C100076544' entPhysicalMfgName.1 == 'Acme' entPhysicalModelName.1 == '100' entPhysicalAlias.1 == 'cl-SJ17-3-006:rack1:rtr-U3' entPhysicalAssetID.1 == '0007372293' entPhysicalIsFRU.1 == true(1) entPhysicalMfgDate.1 == '2002-5-26,13:30:30.0,-4:0' entPhysicalUris.1 == 'URN:CLEI:CNME120ARA' 2 slots within the chassis: entPhysicalDescr.2 == 'Acme Chassis Slot Type AA' entPhysicalVendorType.2 == acmeProducts.slotTypes.1 entPhysicalContainedIn.2 == 1 entPhysicalClass.2 == container(5) entPhysicalParentRelPos.2 == 1 entPhysicalName.2 == 'S1' entPhysicalHardwareRev.2 == 'B(1.00.01)' entPhysicalSoftwareRev.2 == '' entPhysicalFirmwareRev.2 == '' entPhysicalSerialNum.2 == '' entPhysicalMfgName.2 == 'Acme' entPhysicalModelName.2 == 'AA' entPhysicalAlias.2 == ''
ToP   noToC   RFC4133 - Page 45
         entPhysicalAssetID.2 ==           ''
         entPhysicalIsFRU.2 ==             false(2)
         entPhysicalMfgDate.2 ==           '2002-7-26,12:22:12.0,-4:0'
         entPhysicalUris.2 ==              'URN:CLEI:CNME123ARA'

         entPhysicalDescr.3 ==             'Acme Chassis Slot Type AA'
         entPhysicalVendorType.3 =         acmeProducts.slotTypes.1
         entPhysicalContainedIn.3 ==       1
         entPhysicalClass.3 ==             container(5)
         entPhysicalParentRelPos.3 ==      2
         entPhysicalName.3 ==              'S2'
         entPhysicalHardwareRev.3 ==       '1.00.07'
         entPhysicalSoftwareRev.3 ==       ''
         entPhysicalFirmwareRev.3 ==       ''
         entPhysicalSerialNum.3 ==         ''
         entPhysicalMfgName.3 ==           'Acme'
         entPhysicalModelName.3 ==         'AA'
         entPhysicalAlias.3 ==             ''
         entPhysicalAssetID.3 ==           ''
         entPhysicalIsFRU.3 ==             false(2)
         entPhysicalMfgDate.3 ==           '2002-7-26,12:12:12.0,-4:0'
         entPhysicalUris.3 ==              'URN:CLEI:CNME123ARA'

       2 Field-replaceable modules:
       Slot 1 contains a module with 3 ports:
         entPhysicalDescr.4 ==             'Acme Router-100'
         entPhysicalVendorType.4  ==       acmeProducts.moduleTypes.14
         entPhysicalContainedIn.4 ==       2
         entPhysicalClass.4 ==             module(9)
         entPhysicalParentRelPos.4 ==      1
         entPhysicalName.4 ==              'M1'
         entPhysicalHardwareRev.4 ==       '1.00.07'
         entPhysicalSoftwareRev.4 ==       '1.4.1'
         entPhysicalFirmwareRev.4 ==       'A(1.1)'
         entPhysicalSerialNum.4 ==         'C100087363'
         entPhysicalMfgName.4 ==           'Acme'
         entPhysicalModelName.4 ==         'R100-FE'
         entPhysicalAlias.4 ==             'rtr-U3:m1:SJ17-3-eng'
         entPhysicalAssetID.4 ==           '0007372462'
         entPhysicalIsFRU.4 ==             true(1)
         entPhysicalMfgDate.4 ==           '2003-7-18,13:30:30.0,-4:0'
         entPhysicalUris.4 ==              'URN:CLEI:CNRU123CAA'

         entPhysicalDescr.5 ==             'Acme Ethernet-100 Port'
         entPhysicalVendorType.5  ==       acmeProducts.portTypes.2
         entPhysicalContainedIn.5 ==       4
         entPhysicalClass.5 ==             port(10)
         entPhysicalParentRelPos.5 ==      1
ToP   noToC   RFC4133 - Page 46
         entPhysicalName.5 ==              'P1'
         entPhysicalHardwareRev.5 ==       'G(1.02)'
         entPhysicalSoftwareRev.5 ==       ''
         entPhysicalFirmwareRev.5 ==       '1.1'
         entPhysicalSerialNum.5 ==         ''
         entPhysicalMfgName.5 ==           'Acme'
         entPhysicalModelName.5 ==         'FE-100'
         entPhysicalAlias.5 ==             ''
         entPhysicalAssetID.5 ==           ''
         entPhysicalIsFRU.5 ==             false(2)
         entPhysicalMfgDate.5 ==           '2003-7-18,14:20:22.0,-4:0'
         entPhysicalUris.5 ==              'URN:CLEI:CNMES23ARA'

         entPhysicalDescr.6 ==             'Acme Ethernet-100 Port'
         entPhysicalVendorType.6  ==       acmeProducts.portTypes.2
         entPhysicalContainedIn.6 ==       4
         entPhysicalClass.6 ==             port(10)
         entPhysicalParentRelPos.6 ==      2
         entPhysicalName.6 ==              'P2'
         entPhysicalHardwareRev.6 ==       'G(1.02)'
         entPhysicalSoftwareRev.6 ==       ''
         entPhysicalFirmwareRev.6 ==       '1.1'
         entPhysicalSerialNum.6 ==         ''
         entPhysicalMfgName.6 ==           'Acme'
         entPhysicalModelName.6 ==         'FE-100'
         entPhysicalAlias.6 ==             ''
         entPhysicalAssetID.6 ==           ''
         entPhysicalIsFRU.6 ==             false(2)
         entPhysicalMfgDate.6 ==           '2003-7-19,10:15:15.0,-4:0'
         entPhysicalUris.6 ==              'URN:CLEI:CNMES23ARA'

         entPhysicalDescr.7 ==             'Acme Router-100 FDDI-Port'
         entPhysicalVendorType.7  ==       acmeProducts.portTypes.3
         entPhysicalContainedIn.7 ==       4
         entPhysicalClass.7 ==             port(10)
         entPhysicalParentRelPos.7 ==      3
         entPhysicalName.7 ==              'P3'
         entPhysicalHardwareRev.7 ==       'B(1.03)'
         entPhysicalSoftwareRev.7 ==       '2.5.1'
         entPhysicalFirmwareRev.7 ==       '2.5F'
         entPhysicalSerialNum.7 ==         ''
         entPhysicalMfgName.7 ==           'Acme'
         entPhysicalModelName.7 ==         'FDDI-100'
         entPhysicalAlias.7 ==             ''
         entPhysicalAssetID.7 ==           ''
         entPhysicalIsFRU.7 ==             false(2)
ToP   noToC   RFC4133 - Page 47
      Slot 2 contains another 3-port module:
         entPhysicalDescr.8 ==             'Acme Router-100 Comm Module'
         entPhysicalVendorType.8  ==       acmeProducts.moduleTypes.15
         entPhysicalContainedIn.8 ==       3
         entPhysicalClass.8 ==             module(9)
         entPhysicalParentRelPos.8 ==      1
         entPhysicalName.8 ==              'M2'
         entPhysicalHardwareRev.8 ==       '2.01.00'
         entPhysicalSoftwareRev.8 ==       '3.0.7'
         entPhysicalFirmwareRev.8 ==       'A(1.2)'
         entPhysicalSerialNum.8 ==         'C100098732'
         entPhysicalMfgName.8 ==           'Acme'
         entPhysicalModelName.8 ==         'C100'
         entPhysicalAlias.8 ==             'rtr-U3:m2:SJ17-2-eng'
         entPhysicalAssetID.8 ==           '0007373982'
         entPhysicalIsFRU.8 ==             true(1)
         entPhysicalMfgDate.8 ==           '2002-5-26,13:30:15.0,-4:0'
         entPhysicalUris.8 ==              'URN:CLEI:CNRT321MAA'

         entPhysicalDescr.9 ==             'Acme Fddi-100 Port'
         entPhysicalVendorType.9 ==        acmeProducts.portTypes.5
         entPhysicalContainedIn.9 ==       8
         entPhysicalClass.9 ==             port(10)
         entPhysicalParentRelPos.9 ==      1
         entPhysicalName.9 ==              'FDDI Primary'
         entPhysicalHardwareRev.9 ==       'CC(1.07)'
         entPhysicalSoftwareRev.9 ==       '2.0.34'
         entPhysicalFirmwareRev.9 ==       '1.1'
         entPhysicalSerialNum.9 ==         ''
         entPhysicalMfgName.9 ==           'Acme'
         entPhysicalModelName.9 ==         'FDDI-100'
         entPhysicalAlias.9 ==             ''
         entPhysicalAssetID.9 ==           ''
         entPhysicalIsFRU.9 ==             false(2)

         entPhysicalDescr.10 ==            'Acme Ethernet-100 Port'
         entPhysicalVendorType.10 ==       acmeProducts.portTypes.2
         entPhysicalContainedIn.10 ==      8
         entPhysicalClass.10 ==            port(10)
         entPhysicalParentRelPos.10 ==     2
         entPhysicalName.10 ==             'Ethernet A'
         entPhysicalHardwareRev.10 ==      'G(1.04)'
         entPhysicalSoftwareRev.10 ==      ''
         entPhysicalFirmwareRev.10 ==      '1.3'
         entPhysicalSerialNum.10 ==        ''
         entPhysicalMfgName.10 ==          'Acme'
         entPhysicalModelName.10 ==        'FE-100'
         entPhysicalAlias.10 ==            ''
ToP   noToC   RFC4133 - Page 48
         entPhysicalAssetID.10 ==          ''
         entPhysicalIsFRU.10 ==            false(2)
         entPhysicalMfgDate.10 ==          '2002-7-26,13:30:15.0,-4:0'
         entPhysicalUris.10 ==             'URN:CLEI:CNMES23ARA'

         entPhysicalDescr.11 ==            'Acme Ethernet-100 Port'
         entPhysicalVendorType.11 ==       acmeProducts.portTypes.2
         entPhysicalContainedIn.11 ==      8
         entPhysicalClass.11 ==            port(10)
         entPhysicalParentRelPos.11 ==     3
         entPhysicalName.11 ==             'Ethernet B'
         entPhysicalHardwareRev.11 ==      'G(1.04)'
         entPhysicalSoftwareRev.11 ==      ''
         entPhysicalFirmwareRev.11 ==      '1.3'
         entPhysicalSerialNum.11 ==        ''
         entPhysicalMfgName.11 ==          'Acme'
         entPhysicalModelName.11 ==        'FE-100'
         entPhysicalAlias.11 ==            ''
         entPhysicalAssetID.11 ==          ''
         entPhysicalIsFRU.11 ==            false(2)
         entPhysicalMfgDate.11 ==          '2002-8-16,15:35:15.0,-4:0'
         entPhysicalUris.11 ==             'URN:CLEI:CNMES23ARA'

      Logical entities -- entLogicalTable; no SNMPv3 support
       2 OSPF instances:
         entLogicalDescr.1 ==              'Acme OSPF v1.1'
         entLogicalType.1 ==               ospf
         entLogicalCommunity.1 ==          'public-ospf1'
         entLogicalTAddress.1 ==           192.0.2.1:161
         entLogicalTDomain.1 ==            snmpUDPDomain
         entLogicalContextEngineID.1 ==    ''
         entLogicalContextName.1 ==        ''

         entLogicalDescr.2 ==              'Acme OSPF v1.1'
         entLogicalType.2 ==               ospf
         entLogicalCommunity.2 ==          'public-ospf2'
         entLogicalTAddress.2 ==           192.0.2.1:161
         entLogicalTDomain.2 ==            snmpUDPDomain
         entLogicalContextEngineID.2 ==    ''
         entLogicalContextName.2 ==        ''

       2 logical bridges:
         entLogicalDescr.3 ==              'Acme Bridge v2.1.1'
         entLogicalType.3  ==              dot1dBridge
         entLogicalCommunity.3 ==          'public-bridge1'
         entLogicalTAddress.3 ==           192.0.2.1:161
         entLogicalTDomain.3 ==            snmpUDPDomain
         entLogicalContextEngineID.3 ==    ''
ToP   noToC   RFC4133 - Page 49
         entLogicalContextName.3 ==        ''

         entLogicalDescr.4 ==              'Acme Bridge v2.1.1'
         entLogicalType.4 ==               dot1dBridge
         entLogicalCommunity.4 ==          'public-bridge2'
         entLogicalTAddress.4 ==           192.0.2.1:161
         entLogicalTDomain.4 ==            snmpUDPDomain
         entLogicalContextEngineID.4 ==    ''
         entLogicalContextName.4 ==        ''

   Logical to Physical Mappings:
     1st OSPF instance: uses module 1-port 1
         entLPPhysicalIndex.1.5 ==         5

     2nd OSPF instance: uses module 2-port 1
         entLPPhysicalIndex.2.9 ==         9

     1st bridge group: uses module 1, all ports

     [ed. -- Note that these mappings are included in the table because
     another logical entity (1st OSPF) utilizes one of the
     ports.  If this were not the case, then a single mapping
     to the module (e.g., entLPPhysicalIndex.3.4) would be
     present instead.]
         entLPPhysicalIndex.3.5 ==         5
         entLPPhysicalIndex.3.6 ==         6
         entLPPhysicalIndex.3.7 ==         7

     2nd bridge group: uses module 2, all ports
         entLPPhysicalIndex.4.9  ==        9
         entLPPhysicalIndex.4.10 ==        10
         entLPPhysicalIndex.4.11 ==        11

   Physical to Logical to MIB Alias Mappings -- entAliasMappingTable:
     Example 1: ifIndex values are global to all logical entities
         entAliasMappingIdentifier.5.0 ==  ifIndex.1
         entAliasMappingIdentifier.6.0 ==  ifIndex.2
         entAliasMappingIdentifier.7.0 ==  ifIndex.3
         entAliasMappingIdentifier.9.0 ==  ifIndex.4
         entAliasMappingIdentifier.10.0 == ifIndex.5
         entAliasMappingIdentifier.11.0 == ifIndex.6

     Example 2: ifIndex values are not shared by all logical entities;
            (Bridge-1 uses ifIndex values 101 - 103 and Bridge-2 uses
   ifIndex values 204-206.)
            entAliasMappingIdentifier.5.0 ==  ifIndex.1
            entAliasMappingIdentifier.5.3 ==  ifIndex.101
            entAliasMappingIdentifier.6.0 ==  ifIndex.2
ToP   noToC   RFC4133 - Page 50
            entAliasMappingIdentifier.6.3 ==  ifIndex.102
            entAliasMappingIdentifier.7.0 ==  ifIndex.3
            entAliasMappingIdentifier.7.3 ==  ifIndex.103
            entAliasMappingIdentifier.9.0 ==  ifIndex.4
            entAliasMappingIdentifier.9.4 ==  ifIndex.204
            entAliasMappingIdentifier.10.0 == ifIndex.5
            entAliasMappingIdentifier.10.4 == ifIndex.205
            entAliasMappingIdentifier.11.0 == ifIndex.6
            entAliasMappingIdentifier.11.4 == ifIndex.206

   Physical Containment Tree -- entPhysicalContainsTable
     chassis has two containers:
         entPhysicalChildIndex.1.2 ==      2
         entPhysicalChildIndex.1.3 ==      3

     container 1 has a module:
         entPhysicalChildIndex.2.4 ==      4

     container 2 has a module:
         entPhysicalChildIndex.3.8 ==      8

     module 1 has 3 ports:
         entPhysicalChildIndex.4.5 ==      5
         entPhysicalChildIndex.4.6 ==      6
         entPhysicalChildIndex.4.7 ==      7

     module 2 has 3 ports:
         entPhysicalChildIndex.8.9 ==      9
         entPhysicalChildIndex.8.10 ==     10
         entPhysicalChildIndex.8.11 ==     11

4.2. Repeaters

The second example is a 3-slot Hub with 2 backplane ethernet segments. Slot three is empty, and the remaining slots contain ethernet repeater modules. Note that this example assumes an older Repeater MIB implementation, (RFC 1516 [RFC1516]) rather than the new Repeater MIB (RFC 2108 [RFC2108]). The new version contains an object called 'rptrPortRptrId', which should be used to identify repeater port groupings, rather than using community strings or contexts. Physical entities -- entPhysicalTable: 1 Field-replaceable physical chassis: entPhysicalDescr.1 == 'Acme Chassis Model 110' entPhysicalVendorType.1 == acmeProducts.chassisTypes.2 entPhysicalContainedIn.1 == 0
ToP   noToC   RFC4133 - Page 51
         entPhysicalClass.1 ==       chassis(3)
         entPhysicalParentRelPos.1 ==0
         entPhysicalName.1 ==        '110-B'
         entPhysicalHardwareRev.1 == 'A(1.02.00)'
         entPhysicalSoftwareRev.1 == ''
         entPhysicalFirmwareRev.1 == ''
         entPhysicalSerialNum.1 ==   'C100079294'
         entPhysicalMfgName.1 ==     'Acme'
         entPhysicalModelName.1 ==   '110'
         entPhysicalAlias.1 ==       'bldg09:floor1:rptr18:0067eea0229f'
         entPhysicalAssetID.1 ==     '0007386327'
         entPhysicalIsFRU.1 ==       true(1)

      2 Chassis Ethernet Backplanes:
         entPhysicalDescr.2 ==          'Acme Ethernet Backplane Type A'
         entPhysicalVendorType.2 ==     acmeProducts.backplaneTypes.1
         entPhysicalContainedIn.2 ==    1
         entPhysicalClass.2 ==          backplane(4)
         entPhysicalParentRelPos.2 ==   1
         entPhysicalName.2 ==           'B1'
         entPhysicalHardwareRev.2 ==    'A(2.04.01)'
         entPhysicalSoftwareRev.2 ==    ''
         entPhysicalFirmwareRev.2 ==    ''
         entPhysicalSerialNum.2 ==      ''
         entPhysicalMfgName.2 ==        'Acme'
         entPhysicalModelName.2 ==      'BK-A'
         entPhysicalAlias.2 ==          ''
         entPhysicalAssetID.2 ==        ''
         entPhysicalIsFRU.2 ==          false(2)

         entPhysicalDescr.3 ==          'Acme Ethernet Backplane Type A'
         entPhysicalVendorType.3  ==    acmeProducts.backplaneTypes.1
         entPhysicalContainedIn.3 ==    1
         entPhysicalClass.3 ==          backplane(4)
         entPhysicalParentRelPos.3 ==   2
         entPhysicalName.3 ==           'B2'
         entPhysicalHardwareRev.3 ==    'A(2.04.01)'
         entPhysicalSoftwareRev.3 ==    ''
         entPhysicalFirmwareRev.3 ==    ''
         entPhysicalSerialNum.3 ==      ''
         entPhysicalMfgName.3 ==        'Acme'
         entPhysicalModelName.3 ==      'BK-A'
         entPhysicalAlias.3 ==          ''
         entPhysicalAssetID.3 ==        ''
         entPhysicalIsFRU.3 ==          false(2)
ToP   noToC   RFC4133 - Page 52
      3 slots within the chassis:
         entPhysicalDescr.4 ==          'Acme Hub Slot Type RB'
         entPhysicalVendorType.4  ==    acmeProducts.slotTypes.5
         entPhysicalContainedIn.4 ==    1
         entPhysicalClass.4 ==          container(5)
         entPhysicalParentRelPos.4 ==   1
         entPhysicalName.4 ==           'Slot 1'
         entPhysicalHardwareRev.4 ==    'B(1.00.03)'
         entPhysicalSoftwareRev.4 ==    ''
         entPhysicalFirmwareRev.4 ==    ''
         entPhysicalSerialNum.4 ==      ''
         entPhysicalMfgName.4 ==        'Acme'
         entPhysicalModelName.4 ==      'RB'
         entPhysicalAlias.4 ==          ''
         entPhysicalAssetID.4 ==        ''
         entPhysicalIsFRU.4 ==          false(2)

         entPhysicalDescr.5 ==          'Acme Hub Slot Type RB'
         entPhysicalVendorType.5  ==    acmeProducts.slotTypes.5
         entPhysicalContainedIn.5 ==    1
         entPhysicalClass.5 ==          container(5)
         entPhysicalParentRelPos.5 ==   2
         entPhysicalName.5 ==           'Slot 2'
         entPhysicalHardwareRev.5 ==    'B(1.00.03)'
         entPhysicalSoftwareRev.5 ==    ''
         entPhysicalFirmwareRev.5 ==    ''
         entPhysicalSerialNum.5 ==      ''
         entPhysicalMfgName.5 ==        'Acme'
         entPhysicalModelName.5 ==      'RB'
         entPhysicalAlias.5 ==          ''
         entPhysicalAssetID.5 ==        ''
         entPhysicalIsFRU.5 ==          false(2)

         entPhysicalDescr.6 ==          'Acme Hub Slot Type RB'
         entPhysicalVendorType.6  ==    acmeProducts.slotTypes.5
         entPhysicalContainedIn.6 ==    1
         entPhysicalClass.6 ==          container(5)
         entPhysicalParentRelPos.6 ==   3
         entPhysicalName.6 ==           'Slot 3'
         entPhysicalHardwareRev.6 ==    'B(1.00.03)'
         entPhysicalSoftwareRev.6 ==    ''
         entPhysicalFirmwareRev.6 ==    ''
         entPhysicalSerialNum.6 ==      ''
         entPhysicalMfgName.6 ==        'Acme'
         entPhysicalModelName.6 ==      'RB'
         entPhysicalAlias.6 ==          ''
         entPhysicalAssetID.6 ==        ''
         entPhysicalIsFRU.6 ==          false(2)
ToP   noToC   RFC4133 - Page 53
      Slot 1 contains a plug-in module with 4 10-BaseT ports:
         entPhysicalDescr.7  ==         'Acme 10Base-T Module 114'
         entPhysicalVendorType.7 ==     acmeProducts.moduleTypes.32
         entPhysicalContainedIn.7  ==   4
         entPhysicalClass.7 ==          module(9)
         entPhysicalParentRelPos.7 ==   1
         entPhysicalName.7 ==           'M1'
         entPhysicalHardwareRev.7 ==    'A(1.02.01)'
         entPhysicalSoftwareRev.7 ==    '1.7.2'
         entPhysicalFirmwareRev.7 ==    'A(1.5)'
         entPhysicalSerialNum.7 ==      'C100096244'
         entPhysicalMfgName.7 ==        'Acme'
         entPhysicalModelName.7 =       '114'
         entPhysicalAlias.7 ==          'bldg09:floor1:eng'
         entPhysicalAssetID.7 ==        '0007962951'
         entPhysicalIsFRU.7 ==          true(1)

         entPhysicalDescr.8 ==          'Acme 10Base-T Port RB'
         entPhysicalVendorType.8 ==     acmeProducts.portTypes.10
         entPhysicalContainedIn.8  ==   7
         entPhysicalClass.8 ==          port(10)
         entPhysicalParentRelPos.8 ==   1
         entPhysicalName.8 ==           'Ethernet-A'
         entPhysicalHardwareRev.8 ==    'A(1.04F)'
         entPhysicalSoftwareRev.8 ==    ''
         entPhysicalFirmwareRev.8 ==    '1.4'
         entPhysicalSerialNum.8 ==      ''
         entPhysicalMfgName.8 ==        'Acme'
         entPhysicalModelName.8 ==      'RB'
         entPhysicalAlias.8 ==          ''
         entPhysicalAssetID.8 ==        ''
         entPhysicalIsFRU.8 ==          false(2)

         entPhysicalDescr.9  ==         'Acme 10Base-T Port RB'
         entPhysicalVendorType.9 ==     acmeProducts.portTypes.10
         entPhysicalContainedIn.9 ==    7
         entPhysicalClass.9 ==          port(10)
         entPhysicalParentRelPos.9 ==   2
         entPhysicalName.9 ==           'Ethernet-B'
         entPhysicalHardwareRev.9 ==    'A(1.04F)'
         entPhysicalSoftwareRev.9 ==    ''
         entPhysicalFirmwareRev.9 ==    '1.4'
         entPhysicalSerialNum.9 ==      ''
         entPhysicalMfgName.9 ==        'Acme'
         entPhysicalModelName.9 =       'RB'
         entPhysicalAlias.9 ==          ''
         entPhysicalAssetID.9 ==        ''
         entPhysicalIsFRU.9 ==          false(2)
ToP   noToC   RFC4133 - Page 54
         entPhysicalDescr.10 ==         'Acme 10Base-T Port RB'
         entPhysicalVendorType.10 ==    acmeProducts.portTypes.10
         entPhysicalContainedIn.10 ==   7
         entPhysicalClass.10 ==         port(10)
         entPhysicalParentRelPos.10 ==  3
         entPhysicalName.10 ==          'Ethernet-C'
         entPhysicalHardwareRev.10 ==   'B(1.02.07)'
         entPhysicalSoftwareRev.10 ==   ''
         entPhysicalFirmwareRev.10 ==   '1.4'
         entPhysicalSerialNum.10 ==     ''
         entPhysicalMfgName.10 ==       'Acme'
         entPhysicalModelName.10 ==     'RB'
         entPhysicalAlias.10 ==         ''
         entPhysicalAssetID.10 ==       ''
         entPhysicalIsFRU.10 ==         false(2)

         entPhysicalDescr.11 ==         'Acme 10Base-T Port RB'
         entPhysicalVendorType.11  ==   acmeProducts.portTypes.10
         entPhysicalContainedIn.11 ==   7
         entPhysicalClass.11 ==         port(10)
         entPhysicalParentRelPos.11 ==  4
         entPhysicalName.11 ==          'Ethernet-D'
         entPhysicalHardwareRev.11 ==   'B(1.02.07)'
         entPhysicalSoftwareRev.11 ==   ''
         entPhysicalFirmwareRev.11 ==   '1.4'
         entPhysicalSerialNum.11 ==     ''
         entPhysicalMfgName.11 ==       'Acme'
         entPhysicalModelName.11 ==     'RB'
         entPhysicalAlias.11 ==         ''
         entPhysicalAssetID.11 ==       ''
         entPhysicalIsFRU.11 ==         false(2)

      Slot 2 contains another ethernet module with 2 ports.
         entPhysicalDescr.12 ==         'Acme 10Base-T Module Model 4'
         entPhysicalVendorType.12 ==    acmeProducts.moduleTypes.30
         entPhysicalContainedIn.12 =    5
         entPhysicalClass.12 ==         module(9)
         entPhysicalParentRelPos.12 ==  1
         entPhysicalName.12 ==          'M2'
         entPhysicalHardwareRev.12 ==   'A(1.01.07)'
         entPhysicalSoftwareRev.12 ==   '1.8.4'
         entPhysicalFirmwareRev.12 ==   'A(1.8)'
         entPhysicalSerialNum.12 ==     'C100102384'
         entPhysicalMfgName.12 ==       'Acme'
         entPhysicalModelName.12 ==     '4'
         entPhysicalAlias.12 ==         'bldg09:floor1:devtest'
         entPhysicalAssetID.12 ==       '0007968462'
         entPhysicalIsFRU.12 ==         true(1)
ToP   noToC   RFC4133 - Page 55
         entPhysicalDescr.13 ==         'Acme 802.3 AUI Port'
         entPhysicalVendorType.13  ==   acmeProducts.portTypes.11
         entPhysicalContainedIn.13 ==   12
         entPhysicalClass.13 ==         port(10)
         entPhysicalParentRelPos.13 ==  1
         entPhysicalName.13 ==          'AUI'
         entPhysicalHardwareRev.13 ==   'A(1.06F)'
         entPhysicalSoftwareRev.13 ==   ''
         entPhysicalFirmwareRev.13 ==   '1.5'
         entPhysicalSerialNum.13 ==     ''
         entPhysicalMfgName.13 ==       'Acme'
         entPhysicalModelName.13 ==     ''
         entPhysicalAlias.13 ==         ''
         entPhysicalAssetID.13 ==       ''
         entPhysicalIsFRU.13 ==         false(2)

         entPhysicalDescr.14 ==         'Acme 10Base-T Port RD'
         entPhysicalVendorType.14  ==   acmeProducts.portTypes.14
         entPhysicalContainedIn.14 ==   12
         entPhysicalClass.14 ==         port(10)
         entPhysicalParentRelPos.14 ==  2
         entPhysicalName.14 ==          'E2'
         entPhysicalHardwareRev.14 ==   'B(1.01.02)'
         entPhysicalSoftwareRev.14 ==   ''
         entPhysicalFirmwareRev.14 ==   '2.1'
         entPhysicalSerialNum.14 ==     ''
         entPhysicalMfgName.14 ==       'Acme'
         entPhysicalModelName.14 ==     ''
         entPhysicalAlias.14 ==         ''
         entPhysicalAssetID.14 ==       ''
         entPhysicalIsFRU.14 ==         false(2)

   Logical entities -- entLogicalTable; with SNMPv3 support
      Repeater 1--comprised of any ports attached to backplane 1
         entLogicalDescr.1 ==           'Acme repeater v3.1'
         entLogicalType.1  ==           snmpDot3RptrMgt
         entLogicalCommunity.1          'public-repeater1'
         entLogicalTAddress.1 ==        192.0.2.1:161
         entLogicalTDomain.1 ==         snmpUDPDomain
         entLogicalContextEngineID.1 == '80000777017c7d7e7f'H
         entLogicalContextName.1 ==     'repeater1'

      Repeater 2--comprised of any ports attached to backplane 2:
         entLogicalDescr.2 ==           'Acme repeater v3.1'
         entLogicalType.2  ==           snmpDot3RptrMgt
         entLogicalCommunity.2 ==       'public-repeater2'
         entLogicalTAddress.2 ==        192.0.2.1:161
         entLogicalTDomain.2 ==         snmpUDPDomain
ToP   noToC   RFC4133 - Page 56
         entLogicalContextEngineID.2 == '80000777017c7d7e7f'H
         entLogicalContextName.2 ==     'repeater2'

   Logical to Physical Mappings -- entLPMappingTable:

     repeater1 uses backplane 1, slot 1-ports 1 & 2, slot 2-port 1
     [ed. -- Note that a mapping to the module is not included,
      because this example represents a port-switchable hub.
      Even though all ports on the module could belong to the
      same repeater as a matter of configuration, the LP port
      mappings should not be replaced dynamically with a single
      mapping for the module (e.g., entLPPhysicalIndex.1.7).
      If all ports on the module shared a single backplane connection,
      then a single mapping for the module would be more appropriate.]

        entLPPhysicalIndex.1.2 ==       2
        entLPPhysicalIndex.1.8 ==       8
        entLPPhysicalIndex.1.9 ==       9
        entLPPhysicalIndex.1.13 ==      13

     repeater2 uses backplane 2, slot 1-ports 3 & 4, slot 2-port 2
         entLPPhysicalIndex.2.3 ==      3
         entLPPhysicalIndex.2.10 ==     10
         entLPPhysicalIndex.2.11 ==     11
         entLPPhysicalIndex.2.14 ==     14

   Physical to Logical to MIB Alias Mappings -- entAliasMappingTable:
     Repeater Port Identifier values are shared by both repeaters:
         entAliasMappingIdentifier.8.0 ==      rptrPortGroupIndex.1.1
         entAliasMappingIdentifier.9.0 ==      rptrPortGroupIndex.1.2
         entAliasMappingIdentifier.10.0 ==     rptrPortGroupIndex.1.3
         entAliasMappingIdentifier.11.0 ==     rptrPortGroupIndex.1.4
         entAliasMappingIdentifier.13.0 ==     rptrPortGroupIndex.2.1
         entAliasMappingIdentifier.14.0 ==     rptrPortGroupIndex.2.2

   Physical Containment Tree -- entPhysicalContainsTable
     chassis has two backplanes and three containers:
         entPhysicalChildIndex.1.2 ==   2
         entPhysicalChildIndex.1.3 ==   3
         entPhysicalChildIndex.1.4 ==   4
         entPhysicalChildIndex.1.5 ==   5
         entPhysicalChildIndex.1.6 ==   6

     container 1 has a module:
         entPhysicalChildIndex.4.7 ==   7

     container 2 has a module
         entPhysicalChildIndex.5.12 ==  12
ToP   noToC   RFC4133 - Page 57
     [ed. -- in this example, container 3 is empty.]

     module 1 has 4 ports:
         entPhysicalChildIndex.7.8 ==   8
         entPhysicalChildIndex.7.9 ==   9
         entPhysicalChildIndex.7.10 ==  10
         entPhysicalChildIndex.7.11 ==  11

     module 2 has 2 ports:
         entPhysicalChildIndex.12.13 == 13
         entPhysicalChildIndex.12.14 == 14

5. Security Considerations

There are a number of management objects defined in this MIB that have a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. There are a number of managed objects in this MIB that may contain sensitive information. These are: entPhysicalDescr entPhysicalVendorType entPhysicalHardwareRev entPhysicalFirmwareRev entPhysicalSoftwareRev entPhysicalSerialNum entPhysicalMfgName entPhysicalModelName These objects expose information about the physical entities within a managed system, which may be used to identify the vendor, model, and version information of each system component. entPhysicalAssetID This object can allow asset identifiers for various system components to be exposed, in the event this MIB object is actually configured by an NMS application. entLogicalDescr entLogicalType These objects expose the type of logical entities present in the managed system.
ToP   noToC   RFC4133 - Page 58
   entLogicalCommunity

      This object exposes community names associated with particular
      logical entities within the system.

   entLogicalTAddress
   entLogicalTDomain

      These objects expose network addresses that can be used to
      communicate with an SNMP agent on behalf of particular logical
      entities within the system.

   entLogicalContextEngineID
   entLogicalContextName

      These objects identify the authoritative SNMP engine that contains
      information on behalf of particular logical entities within the
      system.

   It is thus important to control even GET access to these objects
   and possibly to even encrypt the values of these object when
   sending them over the network via SNMP.  Not all versions of SNMP
   provide features for such a secure environment.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), even then, there is
   no control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework.  Specifically, the
   use of the User-based Security Model RFC 3414 [RFC3414] and the
   View-based Access Control Model RFC 3415 [RFC3415] is recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.

6. IANA Considerations

The MIB module in this document uses the following IANA-assigned OBJECT IDENTIFIER values recorded in the SMI Numbers registry: Descriptor OBJECT IDENTIFIER value ---------- ----------------------- entityMIB { mib-2 47 }
ToP   noToC   RFC4133 - Page 59

7. Acknowledgements

This memo has been produced by the IETF's Entity MIB working group.

8. References

8.1. Normative References

[RFC2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks", STD 62, RFC 3411, December 2002. [RFC3417] Presuhn, R., "Transport Mappings for the Simple Network Management Protocol (SNMP)", STD 62, RFC 3417, December 2002. [RFC3986] Berners-Lee, T., Fielding, R., and L. Masinter, "Uniform Resource Identifier (URI): Generic Syntax", STD 66, RFC 3986, January 2005.

8.2. Informative References

[RFC1157] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple Network Management Protocol", STD 15, RFC 1157, May 1990. [RFC1493] Decker, E., Langille, P., Rijsinghani, A., and K. McCloghrie, "Definitions of Managed Objects for Bridges", RFC 1493, July 1993. [RFC1516] McMaster, D. and K. McCloghrie, "Definitions of Managed Objects for IEEE 802.3 Repeater Devices", RFC 1516, September 1993.
ToP   noToC   RFC4133 - Page 60
   [RFC2037]     McCloghrie, K. and A. Bierman, "Entity MIB using
                 SMIv2", RFC 2037, October 1996.

   [RFC2108]     de Graaf, K., Romascanu, D., McMaster, D., and K.
                 McCloghrie, "Definitions of Managed Objects for IEEE
                 802.3 Repeater Devices using SMIv2", RFC 2108, February
                 1997.

   [RFC2737]     McCloghrie, K. and A. Bierman, "Entity MIB (Version
                 2)", RFC 2737, December 1999.

   [RFC2863]     McCloghrie, K. and F. Kastenholz, "The Interfaces Group
                 MIB", RFC 2863, June 2000.

   [RFC3406]     Daigle, L., van Gulik, D., Iannella, R., and P.
                 Faltstrom, "Uniform Resource Names (URN) Namespace
                 Definition Mechanisms", BCP 66, RFC 3406, October 2002.

   [RFC3410]     Case, J., Mundy, R., Partain, D., and B. Stewart,
                 "Introduction and Applicability Statements for
                 Internet-Standard Management Framework", RFC 3410,
                 December 2002.

   [RFC3414]     Blumenthal, U. and B. Wijnen, "User-based Security
                 Model (USM) for version 3 of the Simple Network
                 Management Protocol (SNMPv3)", STD 62, RFC 3414,
                 December 2002.

   [RFC3415]     Wijnen, B., Presuhn, R., and K. McCloghrie, "View-based
                 Access Control Model (VACM) for the Simple Network
                 Management Protocol (SNMP)", STD 62, RFC 3415, December
                 2002.

   [RFC4152]     Tesink, K. and R. Fox, "A Uniform Resource Name (URN)
                 Namespace for the CLEI Code", RFC 4152, August 2005.

   [T1.213]      ATIS T1.213-2001, "Coded Identification of Equipment
                 Entities in the North American Telecommunications
                 System for Information Exchange", 2001, www.ansi.org.

   [T1.213a]     ATIS T1.213a, "Supplement to T1.213-2001, Coded
                 Identification of Equipment Entities in the North
                 American Telecommunications System for Information
                 Exchange, to correct the representation of the Basic
                 Code in Figure B.1", 2001, www.ansi.org.
ToP   noToC   RFC4133 - Page 61

Authors' Addresses

Andy Bierman EMail: ietf@andybierman.com Keith McCloghrie Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134 USA Phone: +1 408-526-5260 EMail: kzm@cisco.com
ToP   noToC   RFC4133 - Page 62
Full Copyright Statement

   Copyright (C) The Internet Society (2005).

   This document is subject to the rights, licenses and restrictions
   contained in BCP 78, and except as set forth therein, the authors
   retain all their rights.

   This document and the information contained herein are provided on an
   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   Intellectual Property Rights or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; nor does it represent that it has
   made any independent effort to identify any such rights.  Information
   on the procedures with respect to rights in RFC documents can be
   found in BCP 78 and BCP 79.

   Copies of IPR disclosures made to the IETF Secretariat and any
   assurances of licenses to be made available, or the result of an
   attempt made to obtain a general license or permission for the use of
   such proprietary rights by implementers or users of this
   specification can be obtained from the IETF on-line IPR repository at
   http://www.ietf.org/ipr.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights that may cover technology that may be required to implement
   this standard.  Please address the information to the IETF at ietf-
   ipr@ietf.org.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.