3. Object Definitions
DS3-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, transmission FROM SNMPv2-SMI -- [RFC2578] DisplayString, TimeStamp, TruthValue FROM SNMPv2-TC -- [RFC2579] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] InterfaceIndex FROM IF-MIB -- [RFC2863] PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB; -- [RFC3593]
ds3 MODULE-IDENTITY LAST-UPDATED "200409080000Z" -- September 08, 2004 ORGANIZATION "IETF AToM MIB Working Group" CONTACT-INFO "WG charter: http://www.ietf.org/html.charters/atommib-charter.html Mailing Lists: General Discussion: atommib@research.telcordia.com To Subscribe: atommib-request@research.telcordia.com Editor: Orly Nicklass Postal: RAD Data Communications, Ltd. Ziv Tower, 24 Roul Walenberg Tel Aviv, Israel, 69719 Tel: +9723 765 9969 E-mail: orly_n@rad.com" DESCRIPTION "The is the MIB module that describes DS3 and E3 interfaces objects. Copyright (c) The Internet Society (2004). This version of this MIB module is part of RFC 3896; see the RFC itself for full legal notices." REVISION "200409080000Z" -- September 08, 2004 DESCRIPTION "The RFC 3896 version of this MIB module. The key changes made to this MIB module since its publication in RFC 2496 are as follows: (1) The dsx3FracIfIndex SYNTAX matches the description range. (2) Reference was added to Circuit Identifier object. (3) Usage of ifStackTable section was updated. (4) Align the DESCRIPTION clauses of few statistic objects with thenear end definition, the far end definition and with RFC 3593. (5) Add new value, dsx3M13, to dsx3LineType." REVISION "199808012130Z"
DESCRIPTION "The RFC 2496 version of this MIB module. The key changes made to this MIB module since its publication in RFC 1407 are as follows: (1) The Fractional Table has been deprecated. (2) This document uses SMIv2. (3) Values are given for ifTable and ifXTable. (4) Example usage of ifStackTable is included. (5) dsx3IfIndex has been deprecated. (6) The definition of valid intervals has been clarified for the case where the agent proxied for other devices. In particular, the treatment of missing intervals has been clarified. (7) An inward loopback has been added. (8) Additional lineStatus bits have been added for Near End in Unavailable Signal State, Carrier Equipment Out of Service. (9) A read-write line Length object has been added. (10) Added a lineStatus last change, trap and enabler. (11) Textual Conventions for statistics objects have been used. (12) A new object, dsx3LoopbackStatus, has been introduced to reflect the loopbacks established on a DS3/E3 interface and the source to the requests. dsx3LoopbackConfig continues to be the desired loopback state while dsx3LoopbackStatus reflects the actual state. (13) A dual loopback has been added to allow the setting of an inward loopback and a line loopback at the same time. (14) An object has been added to indicated whether or not this is a channelized DS3/E3. (15) A new object has been added to indicate which DS1 is to set for remote loopback."
REVISION "199301252028Z" DESCRIPTION "Initial version, published as RFC 1407." ::= { transmission 30 } -- The DS3/E3 Near End Group -- The DS3/E3 Near End Group consists of four tables: -- DS3/E3 Configuration -- DS3/E3 Current -- DS3/E3 Interval -- DS3/E3 Total -- the DS3/E3 Configuration Table dsx3ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 Configuration table." ::= { ds3 5 } dsx3ConfigEntry OBJECT-TYPE SYNTAX Dsx3ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3/E3 Configuration table." INDEX { dsx3LineIndex } ::= { dsx3ConfigTable 1 } Dsx3ConfigEntry ::= SEQUENCE { dsx3LineIndex InterfaceIndex, dsx3IfIndex InterfaceIndex, dsx3TimeElapsed INTEGER, dsx3ValidIntervals INTEGER, dsx3LineType INTEGER, dsx3LineCoding INTEGER, dsx3SendCode INTEGER, dsx3CircuitIdentifier DisplayString, dsx3LoopbackConfig INTEGER, dsx3LineStatus INTEGER, dsx3TransmitClockSource INTEGER, dsx3InvalidIntervals INTEGER, dsx3LineLength INTEGER, dsx3LineStatusLastChange TimeStamp,
dsx3LineStatusChangeTrapEnable INTEGER, dsx3LoopbackStatus INTEGER, dsx3Channelization INTEGER, dsx3Ds1ForRemoteLoop INTEGER } dsx3LineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of ifStackTable. Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers." ::= { dsx3ConfigEntry 1 } dsx3IfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213)." ::= { dsx3ConfigEntry 2 } dsx3TimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the
beginning of the near end current error- measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx3ConfigEntry 3 } dsx3ValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx3ConfigEntry 4 } dsx3LineType OBJECT-TYPE SYNTAX INTEGER { dsx3other(1), dsx3M23(2), dsx3SYNTRAN(3), dsx3CbitParity(4), dsx3ClearChannel(5), e3other(6), e3Framed(7), e3Plcp(8), dsx3M13(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe:
TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 dsx3SYNTRAN ANSI T1.107-1988 dsx3CbitParity ANSI T1.107a-1990 dsx3ClearChannel ANSI T1.102-1987 e3Framed CCITT G.751 e3Plcp ETSI T/NA(91)18 dsx3M13 ANSI T1.107a-1990." REFERENCE "American National Standard for telecommunications - digital hierarchy - formats specification, ANSI T1.107- 1988. ANSI T1.107a-1990. American National Standard for telecommunications - digital hierarchy - electrical interfaces, ANSI T1.102- 1987. CCITT - Digital Multiplex Equipment Operating at the Third Order Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264 Kbit/s and Using Positive Justification, G.751 European Telecommunications Standards Institute -- ETS '34M' -- Metropolitan Area Network Physical Convergence Layer Procedure for 34.368 Megabits per Second, T/NA(91)18, May 1991." ::= { dsx3ConfigEntry 5 } dsx3LineCoding OBJECT-TYPE SYNTAX INTEGER { dsx3Other(1), dsx3B3ZS(2), e3HDB3(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx3B3ZS and e3HDB3 refer to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length." ::= { dsx3ConfigEntry 6 } dsx3SendCode OBJECT-TYPE
SYNTAX INTEGER { dsx3SendNoCode(1), dsx3SendLineCode(2), dsx3SendPayloadCode(3), dsx3SendResetCode(4), dsx3SendDS1LoopCode(5), dsx3SendTestPattern(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 interfaces.) Setting this variable causes the interface to begin sending the code requested. The values mean: dsx3SendNoCode sending looped or normal data dsx3SendLineCode sending a request for a line loopback dsx3SendPayloadCode sending a request for a payload loopback (i.e., all DS1/E1s in a DS3/E3 frame) dsx3SendResetCode sending a loopback deactivation request dsx3SendDS1LoopCode requesting to loopback a particular DS1/E1 within a DS3/E3 frame. The DS1/E1 is indicated in dsx3Ds1ForRemoteLoop. dsx3SendTestPattern sending a test pattern." ::= { dsx3ConfigEntry 7 } dsx3CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting."
REFERENCE "ITU-T M.1400" ::= { dsx3ConfigEntry 8 } dsx3LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { dsx3NoLoop(1), dsx3PayloadLoop(2), dsx3LineLoop(3), dsx3OtherLoop(4), dsx3InwardLoop(5), dsx3DualLoop(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the desired loopback configuration of the DS3/E3 interface. The values mean: dsx3NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value. dsx3PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. dsx3LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out. dsx3OtherLoop Loopbacks that are not defined here. dsx3InwardLoop The sent signal at this interface is looped back through the device. dsx3DualLoop Both dsx1LineLoop and dsx1InwardLoop will be active simultaneously." ::= { dsx3ConfigEntry 9 }
dsx3LineStatus OBJECT-TYPE SYNTAX INTEGER (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm must be set if and only if no other flag is set. If the dsx3loopbackState bit is set, the loopback in effect can be determined from the dsx3loopbackConfig object. The various bit positions are: 1 dsx3NoAlarm No alarm present 2 dsx3RcvRAIFailure Receiving Yellow/Remote Alarm Indication 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote Alarm Indication 8 dsx3RcvAIS Receiving AIS failure state 16 dsx3XmitAIS Transmitting AIS 32 dsx3LOF Receiving LOF failure state 64 dsx3LOS Receiving LOS failure state 128 dsx3LoopbackState Looping the received signal 256 dsx3RcvTestCode Receiving a Test Pattern 512 dsx3OtherFailure any line status not defined here 1024 dsx3UnavailSigState Near End in Unavailable Signal State 2048 dsx3NetEquipOOS Carrier Equipment Out of Service" ::= { dsx3ConfigEntry 10 } dsx3TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock.
loopTiming indicates that the recovered receive clock is used as the transmit clock. localTiming indicates that a local clock source is used or that an external clock is attached to the box containing the interface. throughTiming indicates that transmit clock is derived from the recovered receive clock of another DS3 interface." ::= { dsx3ConfigEntry 11 } dsx3InvalidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION " The number of intervals in the range from 0 to dsx3ValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations)." ::= { dsx3ConfigEntry 12 } dsx3LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 } dsx3LineStatusLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value." ::= { dsx3ConfigEntry 14 }
dsx3LineStatusChangeTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether dsx3LineStatusChange traps should be generated for this interface." DEFVAL { disabled } ::= { dsx3ConfigEntry 15 } dsx3LoopbackStatus OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks established by a manager and remotely from the far end. The dsx3LoopbackStatus is a bit map represented as a sum, therefore is can represent multiple loopbacks simultaneously. The various bit positions are: 1 dsx3NoLoopback 2 dsx3NearEndPayloadLoopback 4 dsx3NearEndLineLoopback 8 dsx3NearEndOtherLoopback 16 dsx3NearEndInwardLoopback 32 dsx3FarEndPayloadLoopback 64 dsx3FarEndLineLoopback" ::= { dsx3ConfigEntry 16 } dsx3Channelization OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledDs1(2), enabledDs2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether this ds3/e3 is channelized or unchannelized. The value of enabledDs1 indicates
that this is a DS3 channelized into DS1s. The value of enabledDs3 indicated that this is a DS3 channelized into DS2s. Setting this object will cause the creation or deletion of DS2 or DS1 entries in the ifTable. " ::= { dsx3ConfigEntry 17 } dsx3Ds1ForRemoteLoop OBJECT-TYPE SYNTAX INTEGER (0..29) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates which DS1/E1 on this DS3/E3 will be indicated in the remote ds1 loopback request. A value of 0 means no DS1 will be looped. A value of 29 means all DS1s/E1s will be looped." ::= { dsx3ConfigEntry 18 } -- the DS3/E3 Current Table dsx3CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 current table contains various statistics being collected for the current 15 minute interval." ::= { ds3 6 } dsx3CurrentEntry OBJECT-TYPE SYNTAX Dsx3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3/E3 Current table." INDEX { dsx3CurrentIndex } ::= { dsx3CurrentTable 1 } Dsx3CurrentEntry ::= SEQUENCE { dsx3CurrentIndex InterfaceIndex, dsx3CurrentPESs PerfCurrentCount, dsx3CurrentPSESs PerfCurrentCount, dsx3CurrentSEFSs PerfCurrentCount, dsx3CurrentUASs PerfCurrentCount, dsx3CurrentLCVs PerfCurrentCount,
dsx3CurrentPCVs PerfCurrentCount, dsx3CurrentLESs PerfCurrentCount, dsx3CurrentCCVs PerfCurrentCount, dsx3CurrentCESs PerfCurrentCount, dsx3CurrentCSESs PerfCurrentCount } dsx3CurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3CurrentEntry 1 } dsx3CurrentPESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Errored Seconds." ::= { dsx3CurrentEntry 2 } dsx3CurrentPSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds." ::= { dsx3CurrentEntry 3 } dsx3CurrentSEFSs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds." ::= { dsx3CurrentEntry 4 }
dsx3CurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds." ::= { dsx3CurrentEntry 5 } dsx3CurrentLCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line Coding Violations." ::= { dsx3CurrentEntry 6 } dsx3CurrentPCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Coding Violations." ::= { dsx3CurrentEntry 7 } dsx3CurrentLESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds." ::= { dsx3CurrentEntry 8 } dsx3CurrentCCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Coding Violations." ::= { dsx3CurrentEntry 9 } dsx3CurrentCESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION
"The number of C-bit Errored Seconds." ::= { dsx3CurrentEntry 10 } dsx3CurrentCSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Severely Errored Seconds." ::= { dsx3CurrentEntry 11 } -- the DS3/E3 Interval Table dsx3IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 Interval Table contains various statistics collected by each DS3/E3 Interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15 minute intervals. Each row in this table represents one such interval (identified by dsx3IntervalNumber) and for one specific interface (identified by dsx3IntervalIndex)." ::= { ds3 7 } dsx3IntervalEntry OBJECT-TYPE SYNTAX Dsx3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3/E3 Interval table." INDEX { dsx3IntervalIndex, dsx3IntervalNumber } ::= { dsx3IntervalTable 1 } Dsx3IntervalEntry ::= SEQUENCE { dsx3IntervalIndex InterfaceIndex, dsx3IntervalNumber INTEGER, dsx3IntervalPESs PerfIntervalCount, dsx3IntervalPSESs PerfIntervalCount, dsx3IntervalSEFSs PerfIntervalCount, dsx3IntervalUASs PerfIntervalCount, dsx3IntervalLCVs PerfIntervalCount, dsx3IntervalPCVs PerfIntervalCount, dsx3IntervalLESs PerfIntervalCount,
dsx3IntervalCCVs PerfIntervalCount, dsx3IntervalCESs PerfIntervalCount, dsx3IntervalCSESs PerfIntervalCount, dsx3IntervalValidData TruthValue } dsx3IntervalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3IntervalEntry 1 } dsx3IntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1." ::= { dsx3IntervalEntry 2 } dsx3IntervalPESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Errored Seconds." ::= { dsx3IntervalEntry 3 } dsx3IntervalPSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds."
::= { dsx3IntervalEntry 4 } dsx3IntervalSEFSs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds." ::= { dsx3IntervalEntry 5 } dsx3IntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds. This object may decrease if the occurrence of unavailable seconds occurs across an interval boundary." ::= { dsx3IntervalEntry 6 } dsx3IntervalLCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line Coding Violations." ::= { dsx3IntervalEntry 7 } dsx3IntervalPCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Coding Violations." ::= { dsx3IntervalEntry 8 } dsx3IntervalLESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds (BPVs or illegal zero sequences)." ::= { dsx3IntervalEntry 9 }
dsx3IntervalCCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Coding Violations." ::= { dsx3IntervalEntry 10 } dsx3IntervalCESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Errored Seconds." ::= { dsx3IntervalEntry 11 } dsx3IntervalCSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Severely Errored Seconds." ::= { dsx3IntervalEntry 12 } dsx3IntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " This variable indicates if the data for this interval is valid." ::= { dsx3IntervalEntry 13 } -- the DS3/E3 Total dsx3TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 Total Table contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval." ::= { ds3 8 } dsx3TotalEntry OBJECT-TYPE SYNTAX Dsx3TotalEntry MAX-ACCESS not-accessible
STATUS current DESCRIPTION "An entry in the DS3/E3 Total table." INDEX { dsx3TotalIndex } ::= { dsx3TotalTable 1 } Dsx3TotalEntry ::= SEQUENCE { dsx3TotalIndex InterfaceIndex, dsx3TotalPESs PerfTotalCount, dsx3TotalPSESs PerfTotalCount, dsx3TotalSEFSs PerfTotalCount, dsx3TotalUASs PerfTotalCount, dsx3TotalLCVs PerfTotalCount, dsx3TotalPCVs PerfTotalCount, dsx3TotalLESs PerfTotalCount, dsx3TotalCCVs PerfTotalCount, dsx3TotalCESs PerfTotalCount, dsx3TotalCSESs PerfTotalCount } dsx3TotalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3TotalEntry 1 } dsx3TotalPESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 2 } dsx3TotalPSESs OBJECT-TYPE SYNTAX PerfTotalCount
MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 3 } dsx3TotalSEFSs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds, encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 4 } dsx3TotalUASs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 5 } dsx3TotalLCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line Coding Violations encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 6 } dsx3TotalPCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit
Coding Violations, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 7 } dsx3TotalLESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds (BPVs or illegal zero sequences) encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 8 } dsx3TotalCCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Coding Violations encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 9 } dsx3TotalCESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 10 } dsx3TotalCSESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 11 }
-- The DS3 Far End Group -- The DS3 Far End Group consists of four tables : -- DS3 Far End Configuration -- DS3 Far End Current -- DS3 Far End Interval -- DS3 Far End Total -- The DS3 Far End Configuration Table dsx3FarEndConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Far End Configuration Table contains configuration information reported in the C-bits from the remote end." ::= { ds3 9 } dsx3FarEndConfigEntry OBJECT-TYPE SYNTAX Dsx3FarEndConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Far End Configuration table." INDEX { dsx3FarEndLineIndex } ::= { dsx3FarEndConfigTable 1 } Dsx3FarEndConfigEntry ::= SEQUENCE { dsx3FarEndLineIndex InterfaceIndex, dsx3FarEndEquipCode DisplayString, dsx3FarEndLocationIDCode DisplayString, dsx3FarEndFrameIDCode DisplayString, dsx3FarEndUnitCode DisplayString, dsx3FarEndFacilityIDCode DisplayString } dsx3FarEndLineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this
index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndConfigEntry 1 } dsx3FarEndEquipCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 2 } dsx3FarEndLocationIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 3 } dsx3FarEndFrameIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 4 } dsx3FarEndUnitCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 5 } dsx3FarEndFacilityIDCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..38)) MAX-ACCESS read-write STATUS current DESCRIPTION "This code identifies a specific Far End DS3 path. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 6 } -- The DS3 Far End Current dsx3FarEndCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Far End Current table contains various statistics being collected for the current 15 minute interval. The statistics are collected from the far end block error code within the C- bits." ::= { ds3 10 } dsx3FarEndCurrentEntry OBJECT-TYPE SYNTAX Dsx3FarEndCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Far End Current table." INDEX { dsx3FarEndCurrentIndex } ::= { dsx3FarEndCurrentTable 1 } Dsx3FarEndCurrentEntry ::= SEQUENCE { dsx3FarEndCurrentIndex InterfaceIndex, dsx3FarEndTimeElapsed INTEGER, dsx3FarEndValidIntervals INTEGER, dsx3FarEndCurrentCESs PerfCurrentCount, dsx3FarEndCurrentCSESs PerfCurrentCount, dsx3FarEndCurrentCCVs PerfCurrentCount, dsx3FarEndCurrentUASs PerfCurrentCount, dsx3FarEndInvalidIntervals INTEGER } dsx3FarEndCurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index
STATUS current DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex." ::= { dsx3FarEndCurrentEntry 1 } dsx3FarEndTimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the far end current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx3FarEndCurrentEntry 2 } dsx3FarEndValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous far end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute far end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx3FarEndCurrentEntry 3 } dsx3FarEndCurrentCESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds." ::= { dsx3FarEndCurrentEntry 4 }