7. Object Definitions

FRSLD-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Integer32, Counter64, TimeTicks, mib-2 FROM SNMPv2-SMI CounterBasedGauge64 FROM HCNUM-TC TEXTUAL-CONVENTION, RowStatus, TimeStamp FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB DLCI FROM FRAME-RELAY-DTE-MIB; frsldMIB MODULE-IDENTITY LAST-UPDATED "200201030000Z" -- January 3, 2002 ORGANIZATION "IETF Frame Relay Service MIB Working Group" CONTACT-INFO "IETF Frame Relay Service MIB (frnetmib) Working Group WG Charter: http://www.ietf.org/html.charters/ frnetmib-charter.html WG-email: frnetmib@sunroof.eng.sun.com Subscribe: frnetmib-request@sunroof.eng.sun.com Email Archive: ftp://ftp.ietf.org/ietf-mail-archive/frnetmib
Top   ToC   RFC3202 - Page 25
           Chair:      Andy Malis
                       Vivace Networks
           Email:      Andy.Malis@vivacenetworks.com

           WG editor:  Robert Steinberger
                       Paradyne Networks and
                       Fujitsu Network Communications
           Email:      robert.steinberger@fnc.fujitsu.com

           Co-author:  Orly Nicklass
                       RAD Data Communications Ltd.
           EMail:      Orly_n@rad.co.il"
        DESCRIPTION
            "The MIB module to describe generic objects for
             FRF.13 Frame Relay Service Level Definitions."
        REVISION "200201030000Z" -- January 3, 2002
        DESCRIPTION
            "Initial version, published as RFC 3202"
        ::= { mib-2 95 }

    --
    -- Textual Conventions
    --
    FrsldTxRP ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "The reference point a PVC uses for calculation
             of transmitter related statistics.

             The valid values for this type of object are as follows:
               - srcLocalRP(1) for the local source
               - ingTxLocalRP(2) for the local ingress queue input
               - tpTxLocalRP(3) for the local traffic policing
               - eqiTxLocalRP(4) for the local egress queue input
               - eqoTxLocalRP(5) for the local egress queue output
               - otherTxLocalRP(6) for any other local transmit point
               - srcRemoteRP(7) for the remote source
               - ingTxLocalRP(8) for the remote ingress queue input
               - tpTxLocalRP(9) for the remote traffic policing
               - eqiTxRemoteRP(10) for the remote egress queue input
               - eqoTxRemoteRP(11) for the remote egress queue output
               - otherTxRemoteRP(12) for any other remote xmit point"
        REFERENCE
            "FRF.13: Section 2.3"
        SYNTAX      INTEGER {
                      srcLocalRP(1),
                      ingTxLocalRP(2),
                      tpTxLocalRP(3),
Top   ToC   RFC3202 - Page 26
                      eqiTxLocalRP(4),
                      eqoTxLocalRP(5),
                      otherTxLocalRP(6),
                      srcRemoteRP(7),
                      ingTxRemoteRP(8),
                      tpTxRemoteRP(9),
                      eqiTxRemoteRP(10),
                      eqoTxRemoteRP(11),
                      otherTxRemoteRP(12)
                    }

    FrsldRxRP ::= TEXTUAL-CONVENTION
        STATUS      current
        DESCRIPTION
            "The reference point a PVC uses for calculation
             of receiver related statistics.

             The valid values for this object are as follows:
               - desLocalRP(1) for the local destination
               - ingRxLocalRP(2) for the local ingress queue input
               - tpRxLocalRP(3) for the local traffic policing
               - eqiRxLocalRP(4) for the local egress queue input
               - eqoRxLocalRP(5) for the local egress queue output
               - otherRxLocalRP(6) for any other local receive point
               - desRemoteRP(7) for the remote destination
               - ingRxRemoteRP(8) for the remote ingress input
               - tpRxRemoteRP(9) for the remote traffic policing
               - eqiRxRemoteRP(10) for the remote egress queue input
               - eqoRxRemoteRP(11) for the remote egress queue output
               - otherRxRemoteRP(12) for any other remote receive point"
        REFERENCE
            "FRF.13: Section 2.3"
        SYNTAX      INTEGER {
                      desLocalRP(1),
                      ingRxLocalRP(2),
                      tpRxLocalRP(3),
                      eqiRxLocalRP(4),
                      eqoRxLocalRP(5),
                      otherRxLocalRP(6),
                      desRemoteRP(7),
                      ingRxRemoteRP(8),
                      tpRxRemoteRP(9),
                      eqiRxRemoteRP(10),
                      eqoRxRemoteRP(11),
                      otherRxRemoteRP(12)
                    }

    --
Top   ToC   RFC3202 - Page 27
    -- Base Objects
    ---

    frsldObjects      OBJECT IDENTIFIER ::= { frsldMIB 1 }
    frsldCapabilities OBJECT IDENTIFIER ::= { frsldMIB 2 }
    frsldConformance  OBJECT IDENTIFIER ::= { frsldMIB 3 }

    -- The Frame Relay Service Level Definitions PVC Control Table
    --
    -- This table is used to define and display the parameters of
    -- service level definitions on individual PVCs.

    frsldPvcCtrlTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldPvcCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             PVC control table."
        ::= { frsldObjects 1 }

    frsldPvcCtrlEntry OBJECT-TYPE
        SYNTAX      FrsldPvcCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions PVC control table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                   frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
        ::= { frsldPvcCtrlTable 1 }

    FrsldPvcCtrlEntry ::=
        SEQUENCE {
            --
            -- Index Control Variables
            --
            frsldPvcCtrlDlci                DLCI,
            frsldPvcCtrlTransmitRP          FrsldTxRP,
            frsldPvcCtrlReceiveRP           FrsldRxRP,
            frsldPvcCtrlStatus              RowStatus,
            --
            -- Service Level Definitions Setup Variables
            --
            frsldPvcCtrlPacketFreq          Integer32,
            --
            -- Delay Specific Setup Variables
            --
Top   ToC   RFC3202 - Page 28
            frsldPvcCtrlDelayFrSize         Integer32,
            frsldPvcCtrlDelayType           INTEGER,
            frsldPvcCtrlDelayTimeOut        Integer32,
            --
            -- Data Persistence Control Variables
            --
            frsldPvcCtrlPurge               Integer32,
            frsldPvcCtrlDeleteOnPurge       INTEGER,
            frsldPvcCtrlLastPurgeTime       TimeStamp
        }

    frsldPvcCtrlDlci OBJECT-TYPE
        SYNTAX      DLCI
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The value of this object is equal to the DLCI
             value for this PVC."
        ::= { frsldPvcCtrlEntry 1 }

    frsldPvcCtrlTransmitRP OBJECT-TYPE
        SYNTAX      FrsldTxRP
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The reference point this PVC uses for calculation
             of transmitter related statistics.  This object
             together with frsldPvcCtrlReceiveRP define the
             measurement domain."
        REFERENCE
            "FRF.13: Section 2.3"
        ::= { frsldPvcCtrlEntry 2 }

    frsldPvcCtrlReceiveRP OBJECT-TYPE
        SYNTAX      FrsldRxRP
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The reference point this PVC uses for calculation
             of receiver related statistics.  This object
             together with frsldPvcCtrlTransmitRP define the
             measurement domain."
        ::= { frsldPvcCtrlEntry 3 }

    frsldPvcCtrlStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
Top   ToC   RFC3202 - Page 29
        DESCRIPTION
            "The status of the current row.  This object is
             used to add, delete, and disable rows in this
             table.  When the status changes to active(1) for the
             first time, a row will also be added to the data
             table below.  This row SHOULD not be removed until
             the status is changed to deleted.

             When this object is set to destroy(6), all associated
             sample and data table rows will also be deleted.
             When this object is changed from active(1) to any
             other valid value, the defined purge behavior will
             affect the data and sample tables.

             The rows added to this table MUST have a valid
             ifIndex and an ifType related to frame relay.  Further,
             the reference points referred to by frsldPvcCtrlTransmitRP
             and frsldPvcCtrlReceiveRP MUST be supported (see the
             frsldRPCaps object).

             If at any point the row is not in the active(1) state
             and the DLCI no longer exists, the state SHOULD
             report notReady(3).

             The data in this table SHOULD persist through power
             cycles.  The symantics of readiness for the rows still
             applies.  This means that it is possible for a row to be
             reprovisioned as notReady(3) if the underlying DLCI does
             not persist."
        ::= { frsldPvcCtrlEntry 4 }

    frsldPvcCtrlPacketFreq OBJECT-TYPE
        SYNTAX      Integer32 (0..3600)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The frequency in seconds between initiation of
             specialized packets used to collect delay and / or
             delivery information as supported by the device.
             A value of zero indicates that no packets will
             be sent."
        DEFVAL { 60 }
        ::= { frsldPvcCtrlEntry 5 }

    frsldPvcCtrlDelayFrSize OBJECT-TYPE
        SYNTAX      Integer32 (1..8188)
        UNITS       "octets"
Top   ToC   RFC3202 - Page 30
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The size of the payload in the frame used for
             calculation of network delay."
        DEFVAL { 128 }
        ::= { frsldPvcCtrlEntry 6 }

    frsldPvcCtrlDelayType OBJECT-TYPE
        SYNTAX      INTEGER {
                      oneWay(1),
                      roundTrip(2)
                    }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The type of delay measurement performed."
        REFERENCE
            "FRF.13: Section 3"
        ::= { frsldPvcCtrlEntry 7 }

    frsldPvcCtrlDelayTimeOut OBJECT-TYPE
        SYNTAX      Integer32 (1..3600)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "A delay frame will count as a missed poll if
             it is not updated in the time specified by
             frsldPvcCtrlDelayTimeOut."
        DEFVAL { 60 }
        ::= { frsldPvcCtrlEntry 8 }

    frsldPvcCtrlPurge OBJECT-TYPE
        SYNTAX      Integer32 (0..172800) -- up to 48 hours
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object defines the amount of time the device
             will wait, after discovering that a DLCI does not exist,
             the DLCI was deleted or the value of frsldPvcCtrlStatus
             changes from active(1) to either notInService(2) or
             notReady(3), prior to automatically purging the history
             in the sample tables and resetting the data in the data
             tables to all zeroes.  If frsldPvcCtrlStatus is manually
             set to destroy(6), this object does not apply."
        DEFVAL { 0 }
Top   ToC   RFC3202 - Page 31
        ::= { frsldPvcCtrlEntry 9 }

    frsldPvcCtrlDeleteOnPurge OBJECT-TYPE
        SYNTAX      INTEGER {
                      none(1),
                      sampleContols(2),
                      all(3)
                    }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object defines whether rows will
             automatically be deleted from the tables
             when the information is purged.

             - A value of none(1) indicates that no rows
               will deleted.  The last known values will
               be preserved.
             - A value of sampleControls(2) indicates
               that all associated sample control rows
               will be deleted.
             - A value of all(3) indicates that all
               associated rows SHOULD be deleted."
        DEFVAL { all }
        ::= { frsldPvcCtrlEntry 10 }

    frsldPvcCtrlLastPurgeTime OBJECT-TYPE
        SYNTAX      TimeStamp
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object returns the value of sysUpTime
             at the time the information was last purged.
             This value SHOULD be set to the sysUpTime
             upon setting frsldPvcCtrlStatus to active(1)
             for the first time.  Each time a
             discontinuity in the counters occurs, this
             value MUST be set to the sysUpTime.

             If frsldPvcCtrlStatus has never been active(1),
             this object SHOULD return 0.

             This object SHOULD be used as the discontinuity
             timer for the counters in frsldPvcDataTable."
        ::= { frsldPvcCtrlEntry 11 }

    -- The Frame Relay Service Level Definitions Sampling Control
    -- Table
Top   ToC   RFC3202 - Page 32
    --
    -- This table is used to define the sample control parameters
    -- of service level definitions on individual PVCs.

    frsldSmplCtrlTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldSmplCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             sampling control table."
        ::= { frsldObjects 2 }

    frsldSmplCtrlEntry OBJECT-TYPE
        SYNTAX      FrsldSmplCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions sample control table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                   frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP,
                   frsldSmplCtrlIdx }
        ::= { frsldSmplCtrlTable 1 }

    FrsldSmplCtrlEntry ::=
        SEQUENCE {
            --
            -- Index Control Variables
            --
            frsldSmplCtrlIdx                Integer32,
            frsldSmplCtrlStatus             RowStatus,
            --
            -- Collection Control Variables
            --
            frsldSmplCtrlColPeriod          Integer32,
            frsldSmplCtrlBuckets            Integer32,
            frsldSmplCtrlBucketsGranted     Integer32
        }

    frsldSmplCtrlIdx OBJECT-TYPE
        SYNTAX  Integer32 (1..256)
        MAX-ACCESS not-accessible
        STATUS  current
        DESCRIPTION
            "The unique index for this row in the
             sample control table."
        ::= { frsldSmplCtrlEntry 1 }
Top   ToC   RFC3202 - Page 33
    frsldSmplCtrlStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The status of the current row.  This object is
             used to add, delete, and disable rows in this
             table.  This row SHOULD NOT be removed until the
             status is changed to destroy(6).  When the status
             changes to active(1), the collection in the sample
             tables below will be activated.

             The rows added to this table MUST have a valid
             ifIndex, an ifType related to frame relay,
             frsldPvcCtrlDlci MUST exist for the specified
             ifIndex and frsldPvcCtrlStatus MUST have a
             value of active(1).

             The value of frsldPvcCtrlStatus MUST be active(1)
             to transition this object to active(1).  If
             the value of frsldPvcCtrlStatus becomes anything
             other than active(1) when the state of this object
             is not active(1), this object SHOULD be set to
             notReady(3).

             The data in this table SHOULD persist through power
             cycles.  The symantics of readiness for the rows still
             applies.  This means that it is possible for a row to be
             reprovisioned as notReady(3) if the underlying DLCI does
             not persist."
        ::= { frsldSmplCtrlEntry 2 }

    frsldSmplCtrlColPeriod OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The amount of time in seconds that defines a
             period of collection for the statistics.
             At the end of each period, the statistics will be
             sampled and a row is added to the sample table."
        ::= { frsldSmplCtrlEntry 3 }

    frsldSmplCtrlBuckets OBJECT-TYPE
        SYNTAX      Integer32 (1..65535)
        MAX-ACCESS  read-create
        STATUS      current
Top   ToC   RFC3202 - Page 34
        DESCRIPTION
            "The number of discrete buckets over which the
             data statistics are sampled.

             When this object is created or modified, the device
             SHOULD attempt to set the frsldSmplCtrlBuckets-
             Granted to a value as close as is possible
             depending upon the implementation and the available
             resources."
        DEFVAL { 60 }
        ::= { frsldSmplCtrlEntry 4 }

    frsldSmplCtrlBucketsGranted OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of discrete buckets granted.  This
             object will return 0 until frsldSmplCtrlStatus is
             set to active(1).  At that time the buckets will be
             allocated depending upon implementation and
             available resources."
        ::= { frsldSmplCtrlEntry 5 }

    -- The Frame Relay Service Level Definitions PVC Data Table
    --
    -- This table contains the accumulated values of
    -- the collected data.  This table is the table that should
    -- be referenced by external polling mechanisms if time
    -- based polling be desired.

     frsldPvcDataTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldPvcDataEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             data table.

             This table contains accumulated values of the
             collected data.  It is the table that should be
             referenced by external polling mechanisms if
             time based polling be desired."
        ::= { frsldObjects 3 }

    frsldPvcDataEntry OBJECT-TYPE
        SYNTAX      FrsldPvcDataEntry
        MAX-ACCESS  not-accessible
Top   ToC   RFC3202 - Page 35
        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions data table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                  frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
        ::= { frsldPvcDataTable 1 }

    FrsldPvcDataEntry ::=
        SEQUENCE {
            frsldPvcDataMissedPolls       Counter32,
            frsldPvcDataFrDeliveredC      Counter32,
            frsldPvcDataFrDeliveredE      Counter32,
            frsldPvcDataFrOfferedC        Counter32,
            frsldPvcDataFrOfferedE        Counter32,
            frsldPvcDataDataDeliveredC    Counter32,
            frsldPvcDataDataDeliveredE    Counter32,
            frsldPvcDataDataOfferedC      Counter32,
            frsldPvcDataDataOfferedE      Counter32,
            frsldPvcDataHCFrDeliveredC    Counter64,
            frsldPvcDataHCFrDeliveredE    Counter64,
            frsldPvcDataHCFrOfferedC      Counter64,
            frsldPvcDataHCFrOfferedE      Counter64,
            frsldPvcDataHCDataDeliveredC  Counter64,
            frsldPvcDataHCDataDeliveredE  Counter64,
            frsldPvcDataHCDataOfferedC    Counter64,
            frsldPvcDataHCDataOfferedE    Counter64,
            frsldPvcDataUnavailableTime   TimeTicks,
            frsldPvcDataUnavailables      Counter32
        }

    frsldPvcDataMissedPolls OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The total number of polls that have been determined
             to be missed.  These polls are typically associated
             with the calculation of delay but may also be
             used for the calculation of other statistics.  If an
             anticipated poll is not received in a reasonable
             amount of time, it should be counted as missed.
             The value used to determine the reasonable amount
             of time is contained in frsldPvcCtrlDelayTimeOut.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
Top   ToC   RFC3202 - Page 36
             frsldPvcCtrlLastPurgeTime."
        ::= { frsldPvcDataEntry 1 }

    frsldPvcDataFrDeliveredC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliveredc)"
        ::= { frsldPvcDataEntry 2 }

    frsldPvcDataFrDeliveredE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliverede)"
        ::= { frsldPvcDataEntry 3 }

    frsldPvcDataFrOfferedC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
Top   ToC   RFC3202 - Page 37
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferedc)"
        ::= { frsldPvcDataEntry 4 }

    frsldPvcDataFrOfferedE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferede)"
        ::= { frsldPvcDataEntry 5 }

    frsldPvcDataDataDeliveredC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliveredc)"
        ::= { frsldPvcDataEntry 6 }

    frsldPvcDataDataDeliveredE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.

             Discontinuities in the value of this counter can
Top   ToC   RFC3202 - Page 38
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliverede)"
        ::= { frsldPvcDataEntry 7 }

    frsldPvcDataDataOfferedC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferedc)"
        ::= { frsldPvcDataEntry 8 }

    frsldPvcDataDataOfferedE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferede)"
        ::= { frsldPvcDataEntry 9 }

    frsldPvcDataHCFrDeliveredC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.  This object is a 64-bit version
             of frsldPvcDataFrDeliveredC.
Top   ToC   RFC3202 - Page 39
             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliveredc)"
        ::= { frsldPvcDataEntry 10 }

    frsldPvcDataHCFrDeliveredE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.  This object is a 64-bit
             version of frsldPvcDataFrDeliveredE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliverede)"
        ::= { frsldPvcDataEntry 11 }

    frsldPvcDataHCFrOfferedC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP within CIR.  This object is
             a 64-bit version of frsldPvcDataFrOfferedC.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferedc)"
        ::= { frsldPvcDataEntry 12 }

    frsldPvcDataHCFrOfferedE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
Top   ToC   RFC3202 - Page 40
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.  This
             object is a 64-bit version of frsldPvcDataFrOfferedE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferede)"
        ::= { frsldPvcDataEntry 13 }

    frsldPvcDataHCDataDeliveredC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.  This object is a 64-bit version of
             frsldPvcDataDataDeliveredC.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliveredc)"
        ::= { frsldPvcDataEntry 14 }

    frsldPvcDataHCDataDeliveredE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.  This object is a 64-bit
             version of frsldPvcDataDataDeliveredE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliverede)"
        ::= { frsldPvcDataEntry 15 }