Tech-invite3GPPspaceIETFspace
96959493929190898887868584838281807978777675747372717069686766656463626160595857565554535251504948474645444342414039383736353433323130292827262524232221201918171615141312111009080706050403020100
in Index   Prev   Next

RFC 1747

Definitions of Managed Objects for SNA Data Link Control (SDLC) using SMIv2

Pages: 67
Historic
Part 2 of 3 – Pages 7 to 36
First   Prev   Next

Top   ToC   RFC1747 - Page 7   prevText
3.  Definitions

SNA-SDLC-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
    Counter32, Integer32, TimeTicks
        FROM SNMPv2-SMI
    DisplayString, RowStatus, TimeInterval
        FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF
    mib-2, ifIndex, ifAdminStatus, ifOperStatus
        FROM RFC1213-MIB;


snaDLC MODULE-IDENTITY
        LAST-UPDATED  "9411150000Z"
        ORGANIZATION  "IETF SNA DLC MIB Working Group"
        CONTACT-INFO
                "        Wayne Clark

                 Postal: cisco Systems, Inc.
                         3100 Smoketree Ct.
                         Suite 1000
                         Raleigh, NC 27604
                         US

                    Tel: +1 919 878 6958

                 E-Mail: wclark@cisco.com"

        DESCRIPTION
                "This is the MIB module for objects used to
                 manage SDLC devices."

::= { mib-2 41 }

--
--  The following data link controls are modelled in this MIB module:
--
--     1. SDLC
--

sdlc        OBJECT IDENTIFIER ::= { snaDLC 1 }
Top   ToC   RFC1747 - Page 8
--
--  THE SDLC GROUP
--  ==============
--
--  The following resources are modelled in the SDLC group of this
--  MIB module:
--
--     1. PORTS
--     2. LINK STATIONS

sdlcPortGroup OBJECT IDENTIFIER ::= { sdlc 1 } -- Physical Ports
sdlcLSGroup   OBJECT IDENTIFIER ::= { sdlc 2 } -- Logical Link Stations

--
--  THE SDLC PORT GROUP
--  ===================
--
--  The following classes of information is modelled for each SDLC port:
--
--     1.  ADMINISTRATIVE ( read/write)
--     2.  OPERATIONAL    ( read-only)
--     3.  STATISTICS     ( read-only)

--  Information not found in this group is found in tables described in
--  the following RFCs:
--
--    1.  RFC1213  - MIB-II
--
--            TABLE                      INDEX
--            ====================       ====================
--        a.  ifTable                    ifIndex
--
--    2.  RFC1659  - The RS232-like MIB
--
--            TABLE                      INDEX
--            ====================       ====================
--        a.  rs232PortTable             rs232PortIndex
--        b.  rs232SyncPortTable         rs232SyncPortIndex
--        c.  rs232InSigTable            rs232InSigPortIndex,
--                                       rs232InSigName
--        d.  rs232OutSigTable           rs232OutSigPortIndex,
--                                       rs232OutSigName
--     ** e.  rs232AsyncPortTable        rs232AsyncPortIndex
--
--     ** rs232AsyncPortTable for ISO 3309.3 ( Start-Stop SDLC).
Top   ToC   RFC1747 - Page 9
--  *************************************************************
--  *                                                           *
--  *           THE SDLC PORT ADMINISTRATIVE TABLE              *
--  *                                                           *
--  *************************************************************

sdlcPortAdminTable  OBJECT-TYPE
                    SYNTAX      SEQUENCE OF SdlcPortAdminEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "This table contains objects that can be
                        changed to manage an SDLC port.    Changing one
                        of these parameters may take effect in the
                        operating port immediately or may wait until
                        the interface is restarted depending on the
                        details of the implementation.

                        Most of the objects in this read-write table
                        have corresponding read-only objects in the
                        sdlcPortOperTable that return the current
                        operating value.

                        The operating values may be different from
                        these configured values if  a configured
                        parameter was changed after the interface was
                        started."
                     ::= { sdlcPortGroup 1 }

sdlcPortAdminEntry  OBJECT-TYPE
                    SYNTAX      SdlcPortAdminEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "A list of configured values for an SDLC port."
                    INDEX   { ifIndex }
                    ::= { sdlcPortAdminTable 1 }

SdlcPortAdminEntry  ::= SEQUENCE
{
        sdlcPortAdminName           DisplayString,
        sdlcPortAdminRole           INTEGER,
        sdlcPortAdminType           INTEGER,
        sdlcPortAdminTopology       INTEGER,
        sdlcPortAdminISTATUS        INTEGER,
        sdlcPortAdminACTIVTO        TimeInterval,
        sdlcPortAdminPAUSE          TimeInterval,
        sdlcPortAdminSERVLIM        Integer32,
Top   ToC   RFC1747 - Page 10
        sdlcPortAdminSlowPollTimer  TimeInterval
}

sdlcPortAdminName   OBJECT-TYPE
                    SYNTAX      DisplayString (SIZE (1..10))
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "An octet string that defines the physical port
                        to which this interface is assigned.  It has
                        implementation-specific significance. Its value
                        shall be unique within the administered
                        system.  It must contain only ASCII printable
                        characters.  Should an implementation choose to
                        accept a write operation  for this object, it
                        causes the logical port definition associated
                        with the table instance to be moved to  a
                        different physical port.  A write operation
                        shall not take effect until the port is cycled
                        inactive."
                    ::= { sdlcPortAdminEntry 1 }

sdlcPortAdminRole   OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                        primary(1),
                        secondary(2),
                        negotiable(3)
                    }
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This object describes the role that the link
                        station shall assume the next time a connection
                        is established.

                        Even though this is defined as a port object,
                        it is a link station attribute in the sense
                        that a role is per link station.  However, it
                        is not possible to vary link station roles on a
                        particular port.  For example, if an SDLC port
                        is configured to primary, all link stations on
                        that port must be primary."
                    ::= { sdlcPortAdminEntry 2 }

sdlcPortAdminType   OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
Top   ToC   RFC1747 - Page 11
                         leased(1),
                         switched(2)
                    }
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This parameter defines whether the SDLC port
                        is to connect to a leased or switched line.  A
                        write operation to this administrative  value
                        shall not take effect until the SDLC port has
                        been cycled inactive."
                    DEFVAL { leased }
                    ::= { sdlcPortAdminEntry 3 }

sdlcPortAdminTopology  OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         pointToPoint(1),
                         multipoint(2)
                    }
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This parameter defines whether the SDLC port is
                        capable of operating in either a point-to-point
                        or multipoint topology.

                        sdlcPortAdminTopology == multipoint implies the
                        port can also operate in a point-to-point
                        topology.  sdlcPortAdminTopology ==
                        pointToPoint does not imply the port can
                        operate in a multipoint topology.

                        A write operation to this administrative value
                        shall not take effect until the SDLC port has
                        been cycled inactive."
                    DEFVAL { pointToPoint }
                    ::= { sdlcPortAdminEntry 4 }

sdlcPortAdminISTATUS  OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         inactive(1),
                         active(2)
                    }
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
Top   ToC   RFC1747 - Page 12
                        "This parameter controls the initial value of
                        the administrative status, ifAdminStatus, of
                        this SDLC port at port start-up.  Depending
                        on the implementation, a write operation to
                        this administrative object may not take effect
                        until the SDLC port has been cycled inactive."
                    DEFVAL { active }
                    ::= { sdlcPortAdminEntry 5 }

sdlcPortAdminACTIVTO    OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This parameter defines the period of time (in
                        1/100ths of a second) that the port will allow a
                        switched line to remain inactive before
                        disconnecting.  A switched line is considered
                        to be inactive if there are no I-Frames being
                        transferred.  A value of zero indicates no
                        timeout.  Depending on the implementation, a
                        write operation to this administered value may
                        not take effect until the port is cycled
                        inactive.

                        This object only has meaning for SDLC ports
                        where sdlcPortAdminType == switched

                        The object descriptor contains the name of an
                        NCP configuration parameter, ACTIVTO.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP ACTIVTO is
                        represented in seconds."
                    DEFVAL { 0 }
                    ::= { sdlcPortAdminEntry 6 }

sdlcPortAdminPAUSE  OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This object defines the minimum elapsed time
                        (in 1/100ths of a second) between any two
                        traversals of the poll list for a primary SDLC
                        port.  Depending on the implementation, a write
                        operation to this administered value  may not
                        take effect until the port is cycled inactive.
Top   ToC   RFC1747 - Page 13
                        The object descriptor contains the name of an
                        NCP configuration parameter, PAUSE.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP PAUSE is
                        represented in 1/10ths of a second.

                        This object only has meaning for SDLC ports
                        where sdlcPortAdminRole == primary "
                    DEFVAL { 200 }
                    ::= { sdlcPortAdminEntry 7 }

sdlcPortAdminSERVLIM OBJECT-TYPE
                    SYNTAX      Integer32
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This object defines the number of times the
                        active poll list will be traversed before
                        polling a station on the slow poll list for a
                        primary, multipoint SDLC port.  Depending  on
                        the implementation, a write operation to this
                        administered value  may not take effect until
                        the port is cycled inactive.

                        This object only has meaning for SDLC ports
                        where
                            sdlcPortAdminRole == primary
                        and
                            sdlcPortAdminTopology == multipoint "
                    DEFVAL { 20 }
                    ::= { sdlcPortAdminEntry 8 }

sdlcPortAdminSlowPollTimer OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-write
                    STATUS      current
                    DESCRIPTION
                        "This object describes the elapsed time (in
                        1/100ths of a second) between polls for failed
                        secondary link station addresses.  Depending
                        on the implementation, a write operation to
                        this administered value  may not take effect
                        until the port is cycled inactive.

                        This object only has meaning for SDLC ports
                        where
                            sdlcPortAdminRole == primary
                        and
Top   ToC   RFC1747 - Page 14
                            sdlcPortAdminTopology == multipoint "
                    DEFVAL { 2000 }
                    ::= { sdlcPortAdminEntry 9 }

--  *************************************************************
--  *                                                           *
--  *                THE SDLC PORT OPERATIONAL TABLE            *
--  *                                                           *
--  *************************************************************

sdlcPortOperTable   OBJECT-TYPE
                    SYNTAX      SEQUENCE OF SdlcPortOperEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "This table contains current SDLC port
                        parameters.  Many of these objects have
                        corresponding objects inthe sdlcPortAdminTable."
                    ::= { sdlcPortGroup 2 }

sdlcPortOperEntry   OBJECT-TYPE
                    SYNTAX      SdlcPortOperEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "Currently set parameters for a specific SDLC
                        port."
                    INDEX   { ifIndex }
                    ::= { sdlcPortOperTable 1 }

SdlcPortOperEntry   ::= SEQUENCE
{
        sdlcPortOperName                DisplayString,
        sdlcPortOperRole                INTEGER,
        sdlcPortOperType                INTEGER,
        sdlcPortOperTopology            INTEGER,
        sdlcPortOperISTATUS             INTEGER,
        sdlcPortOperACTIVTO             TimeInterval,
        sdlcPortOperPAUSE               TimeInterval,
        sdlcPortOperSlowPollMethod      INTEGER,
        sdlcPortOperSERVLIM             Integer32,
        sdlcPortOperSlowPollTimer       TimeInterval,
        sdlcPortOperLastModifyTime      TimeTicks,
        sdlcPortOperLastFailTime        TimeTicks,
        sdlcPortOperLastFailCause       INTEGER
}

sdlcPortOperName    OBJECT-TYPE
Top   ToC   RFC1747 - Page 15
                    SYNTAX      DisplayString (SIZE (1..8))
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "An octet string that describes the physical
                        port to which this interface is currently
                        attached.  It has  implementation-specific
                        significance."
                    ::= { sdlcPortOperEntry 1 }

sdlcPortOperRole    OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                        primary(1),
                        secondary(2),
                        undefined(3)
                    }
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object describes the role that the link
                        station has assumed on this connection.

                        Even though this is defined as a port object,
                        it is a link station attribute in the sense
                        that a role is per link station.  However, it
                        is not possible to vary link station roles on a
                        particular port.  For example, if an SDLC port
                        is configured to primary, all link stations on
                        that port must be primary.

                        The value of sdlcPortOperRole is undefined(3)
                        whenever the link station role has not yet been
                        established by the mode setting command."
                    ::= { sdlcPortOperEntry 2 }

sdlcPortOperType    OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         leased(1),
                         switched(2)
                    }
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This parameter defines whether the SDLC port
                        is currently operating as though connected to a
                        leased or switched line."
Top   ToC   RFC1747 - Page 16
                    ::= { sdlcPortOperEntry 3 }

sdlcPortOperTopology  OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         pointToPoint(1),
                         multipoint(2)
                    }
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This parameter defines whether the SDLC port is
                        currently operating in a point-to-point or
                        multipoint topology."
                    ::= { sdlcPortOperEntry 4 }

sdlcPortOperISTATUS OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         inactive(1),
                         active(2)
                    }
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This parameter describes the initial value of
                        the administrative status, ifAdminStatus, of
                        this SDLC port at last port start-up."
                    ::= { sdlcPortOperEntry 5 }


sdlcPortOperACTIVTO OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This parameter defines the period of time (in
                        100ths of a second) that the port will allow a
                        switched line to remain inactive before
                        disconnecting.  A switched line is considered
                        to be inactive if there are no I-Frames being
                        transferred.

                        The object descriptor contains the name of an
                        NCP configuration parameter, ACTIVTO.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP ACTIVTO is
                        represented in seconds.
Top   ToC   RFC1747 - Page 17
                        A value of zero indicates no timeout."
                    ::= { sdlcPortOperEntry 6 }

sdlcPortOperPAUSE   OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object describes the current minimum
                        elapsed time (in 1/100ths of a second) between
                        any two traversals of the poll list for a
                        primary SDLC port.

                        The object descriptor contains the name of an
                        NCP configuration parameter, PAUSE.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP PAUSE is
                        represented in 1/10ths of a second.

                        This object only has meaning for SDLC ports
                        where
                            sdlcPortAdminRole == primary "
                    ::= { sdlcPortOperEntry 7 }

sdlcPortOperSlowPollMethod OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         servlim(1),
                         pollpause(2),
                         other(3)
                    }
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object defines the exact method that is in
                        effect for periodically polling failed secondary
                        link station addresses.

                        If sdlcPortOperSlowPollMethod == servlim, then
                        sdlcPortOperSERVLIM defines the actual polling
                        characteristics.

                        If sdlcPortOperSlowPollMethod == pollpause,
                        then sdlcPortOperSlowPollTimer defines the
                        actual polling characteristics.

                        If sdlcPortOperSlowPollMethod == other, then
                        the polling characteristics are modeled in
Top   ToC   RFC1747 - Page 18
                        vendor-specific objects.

                        This object only has meaning for SDLC ports
                        where
                            sdlcPortOperRole == primary
                        and
                            sdlcPortOperTopology == multipoint "
                    ::= { sdlcPortOperEntry 8 }

sdlcPortOperSERVLIM OBJECT-TYPE
                    SYNTAX      Integer32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object describes the number of times the
                        active poll list is currently being traversed
                        before polling a station on the slow poll list
                        for a primary, multipoint SDLC port.

                        This object only has meaning for SDLC ports
                        where
                            sdlcPortOperRole == primary
                        and
                            sdlcPortOperTopology == multipoint "
                    ::= { sdlcPortOperEntry 9 }

sdlcPortOperSlowPollTimer OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object describes the elapsed time (in
                        1/100ths of a second) between polls for failed
                        secondary link station addresses.

                        This object only has meaning for SDLC ports
                        where
                            sdlcPortOperRole == primary
                        and
                            sdlcPortOperTopology == multipoint "
                    ::= { sdlcPortOperEntry 10 }

sdlcPortOperLastModifyTime    OBJECT-TYPE
                    SYNTAX      TimeTicks
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object describes the value of sysUpTime
Top   ToC   RFC1747 - Page 19
                         when this port definition was last modified.
                         If the port has not been modified, then this
                         value shall be zero."
                    ::= { sdlcPortOperEntry 11 }

sdlcPortOperLastFailTime    OBJECT-TYPE
                    SYNTAX      TimeTicks
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object describes the value of sysUpTime
                        when this SDLC port last failed.  If the port
                        has not failed, then this value shall be zero."
                    ::= { sdlcPortOperEntry 12 }

sdlcPortOperLastFailCause    OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                        undefined(1),
                        physical(2)
                    }
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This enumerated object describes the cause of
                        the last failure of this SDLC port.  If the
                        port has not failed, then this object has a
                        value of undefined(1)."
                    DEFVAL { undefined }
                    ::= { sdlcPortOperEntry 13 }
Top   ToC   RFC1747 - Page 20
--  *************************************************************
--  *                                                           *
--  *           THE SDLC PORT STATISTICS TABLE                  *
--  *                                                           *
--  *************************************************************

sdlcPortStatsTable  OBJECT-TYPE
                    SYNTAX      SEQUENCE OF SdlcPortStatsEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "Each entry in this table contains statistics
                        for a specific SDLC port."
                     ::= { sdlcPortGroup 3 }

sdlcPortStatsEntry  OBJECT-TYPE
                    SYNTAX      SdlcPortStatsEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "A list of statistics for an SDLC port."
                    INDEX   { ifIndex }
                    ::= { sdlcPortStatsTable 1 }

SdlcPortStatsEntry ::= SEQUENCE
{
        sdlcPortStatsPhysicalFailures Counter32,
        sdlcPortStatsInvalidAddresses Counter32,
        sdlcPortStatsDwarfFrames      Counter32,
        sdlcPortStatsPollsIn          Counter32,
        sdlcPortStatsPollsOut         Counter32,
        sdlcPortStatsPollRspsIn       Counter32,
        sdlcPortStatsPollRspsOut      Counter32,
        sdlcPortStatsLocalBusies      Counter32,
        sdlcPortStatsRemoteBusies     Counter32,
        sdlcPortStatsIFramesIn        Counter32,
        sdlcPortStatsIFramesOut       Counter32,
        sdlcPortStatsOctetsIn         Counter32,
        sdlcPortStatsOctetsOut        Counter32,
        sdlcPortStatsProtocolErrs     Counter32,
        sdlcPortStatsActivityTOs      Counter32,
        sdlcPortStatsRNRLIMITs        Counter32,
        sdlcPortStatsRetriesExps      Counter32,
        sdlcPortStatsRetransmitsIn    Counter32,
        sdlcPortStatsRetransmitsOut   Counter32
}

sdlcPortStatsPhysicalFailures OBJECT-TYPE
Top   ToC   RFC1747 - Page 21
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object reflects the total number of times
                        this port has failed due to its physical media
                        since port startup.  At port startup time,
                        this object must be initialized to zero."
                    ::= { sdlcPortStatsEntry 1 }

sdlcPortStatsInvalidAddresses OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object reflects the total number of
                        frames received by this port with invalid link
                        station addresses."
                    ::= { sdlcPortStatsEntry 2 }

sdlcPortStatsDwarfFrames OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                        "This object reflects the total number of
                        frames received by this port which were
                        delivered intact by the physical layer but were
                        too short to be legal.

                        Ignoring the frame check sequence (FCS), a
                        frame is considered to be too short if it
                        is less than 2 bytes for sdlcLSOperMODULO of
                        eight, or if it is less than 3 bytes for
                        sdlcLSOperMODULO of onetwentyeight."

                    ::= { sdlcPortStatsEntry 3 }

sdlcPortStatsPollsIn OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of polls
                         received by this port since the port was
                         created."

                    ::= { sdlcPortStatsEntry 4 }
Top   ToC   RFC1747 - Page 22
sdlcPortStatsPollsOut OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of polls
                         sent by this port since the port was created."

                    ::= { sdlcPortStatsEntry 5 }

sdlcPortStatsPollRspsIn OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of poll
                         responses received by this port since the port
                         was created."

                    ::= { sdlcPortStatsEntry 6 }

sdlcPortStatsPollRspsOut OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of poll
                         responses sent by this port since the port was
                         created."

                    ::= { sdlcPortStatsEntry 7 }

sdlcPortStatsLocalBusies OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         times that the local SDLC link stations on
                         this port have entered a busy state (RNR).
                         This object is initialized to zero when the
                         port is created."
                    ::= { sdlcPortStatsEntry 8 }

sdlcPortStatsRemoteBusies OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
Top   ToC   RFC1747 - Page 23
                    DESCRIPTION
                         "This object reflects the total number of
                         times that the adjacent (i.e., remote) SDLC
                         link stations on this port have entered a busy
                         state (RNR).  This object is initialized to
                         zero when the port is created."
                    ::= { sdlcPortStatsEntry 9 }

sdlcPortStatsIFramesIn OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         I-Frames that have been received by SDLC link
                         stations on this port.  This object is
                         initialized to zero when the port is created."
                    ::= { sdlcPortStatsEntry 10 }

sdlcPortStatsIFramesOut OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         I-Frames that have been transmitted by SDLC
                         link stations on this port.  This object is
                         initialized to zero when the port is created."
                    ::= { sdlcPortStatsEntry 11 }

sdlcPortStatsOctetsIn OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total octets
                         received from adjacent SDLC link stations on
                         this port.  This object covers the address,
                         control, and information field of I-Frames
                         only.  This object is initialized to zero when
                         the port is created."
                    ::= { sdlcPortStatsEntry 12 }

sdlcPortStatsOctetsOut OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
Top   ToC   RFC1747 - Page 24
                         "This object reflects the total octets
                         transmitted to adjacent SDLC link stations on
                         this port.  This object covers the address,
                         control, and information field of I-Frames
                         only.  This object is initialized to zero when
                         the port is created."
                    ::= { sdlcPortStatsEntry 13 }

sdlcPortStatsProtocolErrs OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         times that the SDLC link stations on this port
                         have deactivated the link as a result of
                         having received a protocol violation from the
                         adjacent link station.  This object is
                         initialized to zero when the port is created."
                    ::= { sdlcPortStatsEntry 14 }

sdlcPortStatsActivityTOs OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         times that the SDLC link stations on this port
                         have deactivated the link as a result of no
                         activity on the link.  This object is
                         initialized to zero when the port is created."
                    ::= { sdlcPortStatsEntry 15 }

sdlcPortStatsRNRLIMITs OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         times that the SDLC link stations on this port
                         have deactivated the link as a result of its
                         RNRLIMIT timer expiring.  This object is
                         initialized to zero when the port is created."
                    ::= { sdlcPortStatsEntry 16 }

sdlcPortStatsRetriesExps OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
Top   ToC   RFC1747 - Page 25
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         times that the SDLC link stations on this port
                         have deactivated the link as a result of a
                         retry sequence being exhausted.  This object
                         is initialized to zero when the port is
                         created."
                    ::= { sdlcPortStatsEntry 17 }

sdlcPortStatsRetransmitsIn OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         I-Frames retransmitted by remote link stations
                         for all SDLC link stations on this port.  This
                         object is initialized to zero when the port is
                         created."
                    ::= { sdlcPortStatsEntry 18 }

sdlcPortStatsRetransmitsOut OBJECT-TYPE
                    SYNTAX      Counter32
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "This object reflects the total number of
                         I-Frames retransmitted by all local SDLC link
                         stations on this port.  This object is
                         initialized to zero when the port is created."
                    ::= { sdlcPortStatsEntry 19 }
Top   ToC   RFC1747 - Page 26
--
--  THE SDLC LINK STATION GROUP
--  ===========================
--

--  The following classes of information is modelled for each SDLC link
--  station:
--
--     1.  ADMINISTRATIVE ( read-write)
--     2.  OPERATIONAL    ( read-only)
--     3.  STATISTICS     ( read-only)

--  *************************************************************
--  *                                                           *
--  *        THE SDLC LINK STATION ADMINISTRATIVE TABLE         *
--  *                                                           *
--  *************************************************************

sdlcLSAdminTable  OBJECT-TYPE
                    SYNTAX      SEQUENCE OF SdlcLSAdminEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                        "This table contains objects that can be
                        changed to manage an SDLC link station.
                        Changing one of these parameters may take
                        effect in the operating link immediately or may
                        wait until the link is restarted depending on
                        the details of the implementation.

                        The entries in sdlcLSAdminTable can be created
                        either by an agent or a management station. The
                        management station can create an entry in
                        sdlcLSAdminTable by setting the appropriate
                        value in sdlcLSAdminRowStatus.

                        Most of the objects in this read-create table
                        have corresponding read-only objects in the
                        sdlcLSOperTable that reflect the current
                        operating value.

                        The operating values may be different from
                        these configured values if changed by XID
                        negotiation or if a configured parameter was
                        changed after the link was started."
                    ::= { sdlcLSGroup 1 }

sdlcLSAdminEntry    OBJECT-TYPE
Top   ToC   RFC1747 - Page 27
                    SYNTAX      SdlcLSAdminEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                         "A list of configured values for an SDLC link
                         station."
                    INDEX   { ifIndex, sdlcLSAddress }
                    ::= { sdlcLSAdminTable 1 }

SdlcLSAdminEntry ::= SEQUENCE
{
        sdlcLSAddress           INTEGER,
        sdlcLSAdminName         DisplayString,
        sdlcLSAdminState        INTEGER,
        sdlcLSAdminISTATUS      INTEGER,
        sdlcLSAdminMAXDATASend  Integer32,
        sdlcLSAdminMAXDATARcv   Integer32,
        sdlcLSAdminREPLYTO      TimeInterval,
        sdlcLSAdminMAXIN        INTEGER,
        sdlcLSAdminMAXOUT       INTEGER,
        sdlcLSAdminMODULO       INTEGER,
        sdlcLSAdminRETRIESm     INTEGER,
        sdlcLSAdminRETRIESt     TimeInterval,
        sdlcLSAdminRETRIESn     Integer32,
        sdlcLSAdminRNRLIMIT     TimeInterval,
        sdlcLSAdminDATMODE      INTEGER,
        sdlcLSAdminGPoll        INTEGER,
        sdlcLSAdminSimRim       INTEGER,
        sdlcLSAdminXmitRcvCap   INTEGER,
        sdlcLSAdminRowStatus    RowStatus
}

sdlcLSAddress       OBJECT-TYPE
                    SYNTAX      INTEGER (1..255)
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                         "This value is the poll address of the
                         secondary link station for this SDLC link.  It
                         uniquely identifies the SDLC link station
                         within a single SDLC port."
                    ::= { sdlcLSAdminEntry 1 }

sdlcLSAdminName     OBJECT-TYPE
                    SYNTAX      DisplayString (SIZE (1..10))
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
Top   ToC   RFC1747 - Page 28
                        "An octet string that defines the local name of
                        the SDLC link station.  This field may be sent
                        in the XID3 control vector 0x0E, type 0xF7."
                    ::= { sdlcLSAdminEntry 2 }

sdlcLSAdminState    OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         inactive(1),
                         active(2)
                    }
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the desired state of the
                        SDLC station.  The managed system shall attempt
                        to keep the operational state, sdlcLSOperState,
                        consistent with this value."
                    DEFVAL { active }
                    ::= { sdlcLSAdminEntry 3 }

sdlcLSAdminISTATUS  OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         inactive(1),
                         active(2)
                    }
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This parameter controls the desired state,
                        sdlcLSAdminState, of the SDLC link station at
                        link station start-up."
                    DEFVAL { active }
                    ::= { sdlcLSAdminEntry 4 }

sdlcLSAdminMAXDATASend  OBJECT-TYPE
                    SYNTAX      Integer32
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object contains the maximum PDU size that
                        the local link station thinks it can send to
                        the adjacent link station before having
                        received any XID from the ALS.  After the
                        maximum PDU size that the ALS can receive is
                        known (via XID exchange) that value is
                        reflected in sdlcLSOperMAXDATASend and takes
Top   ToC   RFC1747 - Page 29
                        precedence over this object.

                        This value includes the Transmission Header
                        (TH) and the Request Header (RH)."
                    ::= { sdlcLSAdminEntry 5 }

sdlcLSAdminMAXDATARcv  OBJECT-TYPE
                    SYNTAX      Integer32
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object contains the maximum PDU size that
                        the local link station can receive from the
                        adjacent link station.  This value is sent in
                        the XID to the ALS.

                        This value includes the Transmission Header
                        (TH) and the Request Header (RH)."
                    ::= { sdlcLSAdminEntry 6 }

sdlcLSAdminREPLYTO  OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the reply timeout (in
                        1/100ths of a second) for an SDLC link
                        station.  If the link station does not receive
                        a response to a poll or message before the
                        specified time expires then the appropriate
                        error recovery shall be initiated.

                        The object descriptor contains the name of an
                        NCP configuration parameter, REPLYTO.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP REPLYTO is
                        represented in 1/10ths of a second.

                        Depending on the implementation, a write
                        operation to this administered value  may not
                        change the operational value, sdlcLSOperREPLYTO,
                        until the link station is cycled inactive.

                        This object only has meaning for SDLC ports
                        where sdlcPortAdminRole == primary "
                    DEFVAL { 100 }
                    ::= { sdlcLSAdminEntry 7 }
Top   ToC   RFC1747 - Page 30
sdlcLSAdminMAXIN    OBJECT-TYPE
                    SYNTAX      INTEGER (1..127)
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the maximum number of
                        unacknowledged I-frames which an SDLC link
                        station may receive.  This should range from 1
                        to (sdlcLSAdminMODULO - 1).  This value is sent
                        in the XID to the ALS.

                        A write operation to this administered value
                        will not change the operational value,
                        sdlcLSOperMAXIN, until the link station is
                        cycled inactive."
                    DEFVAL { 7 }
                    ::= { sdlcLSAdminEntry 8 }

sdlcLSAdminMAXOUT   OBJECT-TYPE
                    SYNTAX      INTEGER (1..127)
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the maximum number of
                        consecutive unacknowledged I-frames which an
                        SDLC link station shall send without an
                        acknowledgement.  This shall range from 1 to
                        (sdlcLSAdminMODULO - 1).

                        For link stations on switched SDLC lines,
                        certain implementions may choose to override
                        this administered value with the value
                        received in the XID exchange.

                        Depending on the implementation, a write
                        operation to this administered value may not
                        change the operational value,
                        sdlcLSOperMAXOUT, until the link station is
                        cycled inactive.

                        An implementation can support only modulo 8,
                        only modulo 128, or both."
                    DEFVAL { 1 }
                    ::= { sdlcLSAdminEntry 9 }

sdlcLSAdminMODULO   OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
Top   ToC   RFC1747 - Page 31
                        eight(8),
                        onetwentyeight(128)
                    }
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the modulus for an SDLC
                        link station.  This modulus determines the size
                        of the rotating acknowledgement window used the
                        SDLC link station pair.

                        A write operation to this administered value
                        will not change the operational value,
                        sdlcLSOperMODULO, until the link station is
                        cycled inactive.

                        An implementation can support only modulo 8,
                        only modulo 128, or both."
                    DEFVAL { eight }
                    ::= { sdlcLSAdminEntry 10 }

sdlcLSAdminRETRIESm OBJECT-TYPE
                    SYNTAX      INTEGER (0..128)
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls number of retries in a
                        retry sequence for the local SDLC link
                        station.  A retry sequence is a series of
                        retransmitted frames ( data or control) for
                        which no positive acknowledgement is received.

                        The number of times that the retry sequence is
                        to be repeated is controlled by the object:
                        sdlcLSAdminRETRIESn.  The interval between retry
                        sequences is controlled by the object:
                        sdlcLSAdminRETRIESt.

                        A value of zero indicates no retries. If the
                        value of sdlcLSAdminRETRIESm is zero, then the
                        values of sdlcLSAdminRETRIESt and
                        sdlcLSAdminRETRIESn should also be zero.

                        Depending on the implementation, a write
                        operation to this administered value  may not
                        change the operational value,
                        sdlcLSOperRETRIESm, until the link station is
                        cycled inactive."
Top   ToC   RFC1747 - Page 32
                    DEFVAL { 15 }
                    ::= { sdlcLSAdminEntry 11 }

sdlcLSAdminRETRIESt OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the interval (in 1/100ths
                        of a second) between retry sequences for the
                        local SDLC link station if multiple retry
                        sequences are specified .  A retry sequence is
                        a series of retransmitted frames ( data or
                        control) for which no positive acknowledgement
                        is received.

                        The number of repeated retries sequences is
                        controlled by the object: sdlcLSAdminRETRIESn.
                        The retries per sequence is controlled by the
                        object:  sdlcLSAdminRETRIESm.

                        The object descriptor contains the name of an
                        NCP configuration parameter, RETRIESt.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP RETRIESt is
                        represented in seconds.

                        Depending on the implementation, a write
                        operation to this administered value  may not
                        change the operational value,
                        sdlcLSOperRETRIESt, until the link station is
                        cycled inactive."
                    DEFVAL { 0 }
                    ::= { sdlcLSAdminEntry 12 }

sdlcLSAdminRETRIESn OBJECT-TYPE
                    SYNTAX      Integer32
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the number of times that
                        a retry sequence is repeated for the local SDLC
                        link station.  A retry sequence is a series of
                        retransmitted frames ( data or control) for
                        which no positive acknowledgement is received.

                        The interval between retry sequences is
                        controlled by the object: sdlcLSAdminRETRIESn.
Top   ToC   RFC1747 - Page 33
                        The retries per sequence is controlled by the
                        object:  sdlcLSAdminRETRIESm.

                        Depending on the implementation, a write
                        operation to this administered value  may not
                        change the operational value,
                        sdlcLSOperRETRIESn, until the link station is
                        cycled inactive."
                    DEFVAL { 0 }
                    ::= { sdlcLSAdminEntry 13 }

sdlcLSAdminRNRLIMIT OBJECT-TYPE
                    SYNTAX      TimeInterval
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the length of time (in
                        1/100ths of a second) that an SDLC link station
                        will allow its adjacent link station to remain
                        in a busy (RNR) state before declaring it
                        inoperative.

                        A value of sdlcLSAdminRNRLIMIT == 0 means there
                        is no limit.

                        The object descriptor contains the name of an
                        NCP configuration parameter, RNRLIMIT.  Please
                        note that the value of this object represents
                        1/100ths of a second while the NCP RNRLIMIT is
                        represented in minutes.

                        Depending on the implementation, a write
                        operation to this administered value  may not
                        change the operational value,
                        sdlcLSOperRNRLIMIT, until the link station is
                        cycled inactive."
                    DEFVAL { 18000 }
                    ::= { sdlcLSAdminEntry 14 }

sdlcLSAdminDATMODE  OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                        half(1),
                        full(2)
                    }
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
Top   ToC   RFC1747 - Page 34
                        "This object controls whether communications
                        mode with the adjacent link station is
                        two-way-alternate (half) or two-way-simultaneous
                        (full).

                        A write operation to this administered value
                        will not change the operational value,
                        sdlcLSOperDATMODE, until the link station is
                        cycled inactive."
                    DEFVAL { half }
                    ::= { sdlcLSAdminEntry 15 }

sdlcLSAdminGPoll    OBJECT-TYPE
                    SYNTAX      INTEGER (0..254)
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object describes the group poll address
                        for this link station instance.  If group poll
                        is not in effect for this link station
                        instance, the value for sdlcLSAdminGPoll should
                        be zero.

                        Depending on the implementation, a write
                        operation to this administered value may not
                        change the operational value, sdlcLSOperGPoll,
                        until the link station is cycled inactive."
                    ::= { sdlcLSAdminEntry 16 }

sdlcLSAdminSimRim   OBJECT-TYPE
                    SYNTAX      INTEGER
                    {
                         no(1),
                         yes(2)
                    }
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the support for
                        transmission and receipt of SIM and RIM control
                        frames for this link station.  The value of
                        this object controls the setting of the
                        transmit-receive capability sent in the XID
                        field."
                    DEFVAL { no }
                    ::= { sdlcLSAdminEntry 17 }

sdlcLSAdminXmitRcvCap OBJECT-TYPE
Top   ToC   RFC1747 - Page 35
                    SYNTAX      INTEGER
                    {
                         twa(1),
                         tws(2)
                    }
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object controls the transmit-receive
                        capabilities for this SDLC link station.  The
                        value of this object establishes the value of
                        the transmit-receive capability indicator sent
                        in the XID image to the adjacent link station."
                    DEFVAL { twa }
                    ::= { sdlcLSAdminEntry 18 }

sdlcLSAdminRowStatus OBJECT-TYPE
                    SYNTAX      RowStatus
                    MAX-ACCESS  read-create
                    STATUS      current
                    DESCRIPTION
                        "This object is used by a management station to
                        create or delete the row entry in
                        sdlcLSAdminTable following the RowStatus
                        textual convention.

                        Upon successful creation of the row, an agent
                        automatically creates a corresponding entry in
                        the sdlcLSOperTable with sdlcLSOperState equal
                        to 'discontacted (1)'."
                    ::= { sdlcLSAdminEntry 19 }

--  *************************************************************
--  *                                                           *
--  *           THE SDLC LINK STATION OPERATIONAL TABLE         *
--  *                                                           *
--  *************************************************************

sdlcLSOperTable     OBJECT-TYPE
                    SYNTAX      SEQUENCE OF SdlcLSOperEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                          "This table contains current SDLC link
                          parameters.  Many of these objects have
                          corresponding objects in the
                          sdlcLSAdminTable."
                    ::= { sdlcLSGroup 2 }
Top   ToC   RFC1747 - Page 36
sdlcLSOperEntry     OBJECT-TYPE
                    SYNTAX      SdlcLSOperEntry
                    MAX-ACCESS  not-accessible
                    STATUS      current
                    DESCRIPTION
                         "A list of status and control values for an
                         SDLC link station."
                    INDEX   { ifIndex, sdlcLSAddress }
                    ::= { sdlcLSOperTable 1 }

SdlcLSOperEntry     ::= SEQUENCE
{
        sdlcLSOperName                  DisplayString,
        sdlcLSOperRole                  INTEGER,
        sdlcLSOperState                 INTEGER,
        sdlcLSOperMAXDATASend           Integer32,
        sdlcLSOperREPLYTO               TimeInterval,
        sdlcLSOperMAXIN                 INTEGER,
        sdlcLSOperMAXOUT                INTEGER,
        sdlcLSOperMODULO                INTEGER,
        sdlcLSOperRETRIESm              INTEGER,
        sdlcLSOperRETRIESt              TimeInterval,
        sdlcLSOperRETRIESn              INTEGER,
        sdlcLSOperRNRLIMIT              TimeInterval,
        sdlcLSOperDATMODE               INTEGER,
        sdlcLSOperLastModifyTime        TimeTicks,
        sdlcLSOperLastFailTime          TimeTicks,
        sdlcLSOperLastFailCause         INTEGER,
        sdlcLSOperLastFailCtrlIn        OCTET STRING,
        sdlcLSOperLastFailCtrlOut       OCTET STRING,
        sdlcLSOperLastFailFRMRInfo      OCTET STRING,
        sdlcLSOperLastFailREPLYTOs      Counter32,
        sdlcLSOperEcho                  INTEGER,
        sdlcLSOperGPoll                 INTEGER,
        sdlcLSOperSimRim                INTEGER,
        sdlcLSOperXmitRcvCap            INTEGER
}

sdlcLSOperName      OBJECT-TYPE
                    SYNTAX      DisplayString (SIZE (1..10))
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION
                         "An octet string that defines the name of the
                         remote SDLC link station.  This field is
                         received in the XID3 control vector 0x0E, type
                         0xF7."
                    ::= { sdlcLSOperEntry 1 }


(next page on part 3)