The measurement request procedure is used by the E-SMLC to obtain timing measurement for a particular target UE from an LMU.
Step 1.
The E-SMLC sends a measurement request to the LMU. The measurement request identifies the UE to be positioned and contains the data (including SRS transmission configuration) needed to obtain the measurements.
Step 2.
In response to step 1, the LMU transfers UL RTOA measurements to the E-SMLC.
The Measurement Update procedure is used by the E-SMLC to inform the LMU of a change in the UE SRS transmission configuration during an ongoing SLmAP measurement reporting transaction.
Step 1.
An SLmAP Measurement reporting transaction is ongoing between the E-SMLC and LMU.
Step 2.
The E-SMLC determines that the SRS transmission configuration data previously sent to the LMU is no longer valid. The E-SMLC sends a Measurement Update to the LMU containing the new SRS transmission configuration data. The E-SMLC shall not send a Measurement Update after receiving a Measurement Response from the LMU.
Step 3.
The LMU continues UL RTOA measurements using the updated SRS configuration.
The measurement abort procedure is used by the E-SMLC to abort an ongoing SLmAP measurement reporting transaction.
Step 1.
An SLmAP Measurement reporting transaction is ongoing between the E-SMLC and LMU.
Step 2.
The E-SMLC determines that the transaction should be aborted (e.g. due to UE detach or inter-MME handover). The E-SMLC sends a measurement abort to the LMU and the ongoing SLmAP Measurement reporting transaction is abandoned. The E-SMLC shall not send a Measurement Abort after receiving a Measurement response from the LMU.