Network Working Group                                     T. Murphy, Jr.
Request for Comments: 2877                                      P. Rieth
Category: Informational                                       J. Stevens
Updates: 1205                                            IBM Corporation
                                                               July 2000


                        5250 Telnet Enhancements

Status of this Memo

   This memo provides information for the Internet community.  It does
   not specify an Internet standard of any kind.  Distribution of this
   memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

Abstract

This memo describes the interface to the IBM 5250 Telnet server that allows client Telnet to request a Telnet terminal or printer session using a specific device name. If a requested device name is not available, a method to retry the request using a new device name is described. Methods to request specific Telnet session settings and auto-signon function are also described. By allowing a Telnet client to select the device name, the 5250 Telnet server opens the door for applications to set and/or extract useful information about the Telnet client. Some possibilities are 1) selecting a customized device name associated with a particular user profile name for National Language Support or subsystem routing, 2) connecting PC and network printers as clients and 3) auto-signon using clear-text or DES-encrypted password exchange. Applications may need to use system API's on the AS/400 in order to extract Telnet session settings from the device name description. Refer to the Retrieve Device Description (QDCRDEVD) API described in the AS/400 System API book [3] on how to extract information using the DEVD0600 and DEVD1100 templates. This memo describes how the IBM 5250 Telnet server supports Work Station Function (WSF) printers using 5250 Display Station Pass- Through. A response code is returned by the Telnet server to indicate success or failure of the WSF printer session.
ToP   noToC   RFC2877 - Page 2

Table of Contents

1. Enhancing Telnet Negotiations...................... 3 2. Standard Telnet Option Negotiation................. 3 3. Enhanced Telnet Option Negotiation................. 4 4. Enhanced Display Emulation Support................. 7 5. Enhanced Display Auto-Signon and Password Encryption......................................... 8 5.1 Password Substitutes Processing.............. 12 5.2 Handling passwords of length 9 and 10........ 14 5.3 Example Password Substitute Calculation...... 15 6. Device Name Collision Processing................... 15 7. Enhanced Printer Emulation Support................. 16 8. Telnet Printer Terminal Types...................... 18 9. Telnet Printer Startup Response Record for Printer Emulators.......................................... 20 9.1 Example of a Success Response Record......... 20 9.2 Example of an Error Response Record.......... 21 9.3 Response Codes............................... 22 10. Printer Steady-State Pass-Through Interface........ 23 10.1 Example of a Print Record.................... 25 10.2 Example of a Print Complete Record........... 27 10.3 Example of a Null Print Record............... 27 11. End-to-End Print Example........................... 28 12. Authors' Note...................................... 33 13. References......................................... 33 14. Security Considerations............................ 35 15. Authors' Addresses................................. 35 16. Relation to Other RFC's............................ 35 17. Full Copyright Statement........................... 36 LIST OF FIGURES Figure 1. Example of a success status response record....................................... 20 Figure 2. Example of an error response record.......... 21 Figure 3. Layout of the printer pass-through header....................................... 23 Figure 4. Server sending client data with a print record....................................... 26 Figure 5. Client sending server a print complete record....................................... 27 Figure 6. Server sending client a null print record....................................... 28
ToP   noToC   RFC2877 - Page 3

1. Enhancing Telnet Negotiations

The 5250 Telnet server enables clients to negotiate both terminal and printer device names through Telnet Environment Options Negotiations, defined in the Standards Track RFC 1572 [13]. The purpose of RFC 1572 is to exchange environment information using a set of standard or custom variables. By using a combination of both standard VAR's and custom USERVAR's, the 5250 Telnet server allows client Telnet to request a pre-defined specific device by name. If no pre-defined device exists then the device will be created, with client Telnet having the option to negotiate device attributes, such as the code page, character set, keyboard type, etc. Since printers can now be negotiated as a device name, new terminal types have been defined to request printers. For example, you can now negotiate "IBM-3812-1" and "IBM-5553-B01" as valid TERMINAL-TYPE options [11]. Finally, the 5250 Telnet server will allow exchange of user profile and password information, where the password may be in either clear- text or encrypted form. If a valid combination of profile and password is received, then the client is allowed to bypass the sign- on panel. The setting of the QRMTSIGN system value must be either *VERIFY or *SAMEPRF for the bypass of the sign-on panel to succeed.

2. Standard Telnet Option Negotiation

Telnet server option negotiation typically begins with the issuance, by the server, of an invitation to engage in terminal type negotiation with the Telnet client (DO TERMINAL-TYPE) [11]. The client and server then enter into a series of sub-negotiations to determine the level of terminal support that will be used. After the terminal type is agreed upon, the client and server will normally negotiate a required set of additional options (EOR [12], BINARY [10], SGA [15]) that are required to support "transparent mode" or full screen 5250/3270 block mode support. As soon as the required options have been negotiated, the server will suspend further negotiations, and begin with initializing the actual virtual device on the AS/400. A typical exchange might start like the following:
ToP   noToC   RFC2877 - Page 4
   AS/400 Telnet server              Enhanced Telnet client
   --------------------------        -------------------------
   IAC DO TERMINAL-TYPE        -->
                               <--   IAC WILL TERMINAL-TYPE
   IAC SB TERMINAL-TYPE SEND
   IAC SE                      -->
                                     IAC SB TERMINAL-TYPE IS
                               <--   IBM-5555-C01 IAC SE
   IAC DO EOR                  -->
                               <--   IAC WILL EOR
                               <--   IAC DO EOR
   IAC WILL EOR                -->
                                .
                                .
   (other negotiations)         .

   Actual bytes transmitted in the above example are shown in hex below.

   AS/400 Telnet server              Enhanced Telnet client
   --------------------------        -------------------------
   FF FD 18                    -->
                               <--   FF FB 18
   FF FA 18 01 FF F0           -->
                                     FF FA 18 00 49 42 4D 2D
                                     35 35 35 35 2D 43 30 31
                               <--   FF F0
   FF FD 19                    -->
                               <--   FF FB 19
                               <--   FF FD 19
   FF FB 19                    -->
                                .
                                .
   (other negotiations)         .

   Some negotiations are symmetrical between client and server and some
   are negotiated in one direction only.  Also, it is permissible and
   common practice to bundle more than one response or request, or
   combine a request with a response, so the actual exchange may look
   different in practice to what is shown above.

3. Enhanced Telnet Option Negotiation

In order to accommodate the new environment option negotiations, the server will bundle an environment option invitation along with the standard terminal type invitation request to the client.
ToP   noToC   RFC2877 - Page 5
   A client should either send a negative acknowledgment (WONT NEW-
   ENVIRON), or at some point after completing terminal-type
   negotiations, but before completing the full set of negotiations
   required for 5250 transparent mode, engage in environment option
   sub-negotiation with the server.  A maximum of 1024 bytes of
   environment strings may be sent to the server.  A recommended
   sequence might look like the following:

   AS/400 Telnet server              Enhanced Telnet client
   --------------------------        -------------------------
   IAC DO NEW-ENVIRON
   IAC DO TERMINAL-TYPE        -->
   (2 requests bundled)
                               <--   IAC WILL NEW-ENVIRON
   IAC SB NEW-ENVIRON SEND
   VAR IAC SE                  -->
                                     IAC SB NEW-ENVIRON IS
                                     VAR "USER" VALUE "JONES"
                                     USERVAR "DEVNAME"
                                     VALUE "MYDEVICE07"
                               <--   IAC SE
                               <--   IAC WILL TERMINAL-TYPE
                                     (do the terminal type
                                     sequence first)
   IAC SB TERMINAL-TYPE SEND
   IAC SE                      -->
                                     IAC SB TERMINAL-TYPE IS
                               <--   IBM-5555-C01 IAC SE
                                     (terminal type negotiations
                                     completed)
   IAC DO EOR                  -->
   (server will continue
   with normal transparent
   mode negotiations)
                               <--   IAC WILL EOR
                                .
                                .
     (other negotiations)       .

   Actual bytes transmitted in the above example are shown in hex below.

   AS/400 Telnet server              Enhanced Telnet client
   --------------------------        -------------------------
   FF FD 27
   FF FD 18                    -->
   (2 requests bundled)
                               <--   FF FB 27
   FF FA 27 01 00 FF F0        -->
ToP   noToC   RFC2877 - Page 6
                                     FF FA 27 00 00 55 53 45
                                     52 01 4A 4F 4E 45 53 03
                                     44 45 56 4E 41 4D 45 01
                                     4D 59 44 45 56 49 43 45
                               <--   30 37 FF F0
                               <--   FF FB 18
                                     (do the terminal type
                                     sequence first)
   FF FA 18 01 FF F0           -->
                                     FF FA 18 00 49 42 4D 2D
                                     35 35 35 35 2D 43 30 31
                               <--   FF F0
   FF FD 19                    -->
   (server will continue
   with normal transparent
   mode negotiations)
                               <--   FF FB 19
                                .
                                .
   (other negotiations)         .

   RFC 1572 defines 6 standard VAR's: USER, JOB, ACCT, PRINTER,
   SYSTEMTYPE, and DISPLAY.  The USER standard VAR will hold the value
   of the AS/400 user profile name to be used in auto-signon requests.
   The Telnet server will make no direct use of the additional 5 VAR's,
   nor are any of them required to be sent.  All standard VAR's and
   their values that are received by the Telnet server will be placed in
   a buffer, along with any USERVAR's received (described below), and
   made available to a registered initialization exit program to be used
   for any purpose desired.

   There are some reasons you may want to send NEW-ENVIRON negotiations
   prior to TERMINAL-TYPE negotiations.  With AS/400 TELNET server,
   several virtual device modes can be negotiated: 1) VTxxx device 2)
   3270 device 3) 5250 device (includes Network Station).  The virtual
   device mode selected depends on the TERMINAL-TYPE negotiated plus any
   other TELNET option negotiations necessary to support those modes.
   The AS/400 TELNET server will create the desired virtual device at
   the first opportunity it thinks it has all the requested attributes
   needed to create the device.  This can be as early as completion of
   the TERMINAL-TYPE negotiations.

   For the case of Transparent mode (5250 device), then the moment
   TERMINAL-TYPE, BINARY, and EOR options are negotiated the TELNET
   server will go create the virtual device.  Receiving any NEW-ENVIRON
   negotiations after these option negotiations are complete will result
   in the NEW-ENVIRON negotiations having no effect on device
   attributes, as the virtual device will have already been created.
ToP   noToC   RFC2877 - Page 7
   So, for Transparent mode, NEW-ENVIRON negotiations are effectively
   closed once EOR is negotiated, since EOR is generally the last option
   done.

   For other devices modes (such as VTxxx or 3270), you cannot be sure
   when the AS/400 TELNET server thinks it has all the attributes to
   create the device.  Recall that NEW-ENVIRON negotiations are
   optional, and therefore the AS/400 TELNET server need not wait for
   any NEW-ENVIRON options prior to creating the virtual device.  It is
   in the clients best interest to send NEW-ENVIRON negotiations as soon
   as possible, preferably before TERMINAL-TYPE is negotiated.  That
   way, the client can be sure the requested attributes were received
   before the virtual device is created.

4. Enhanced Display Emulation Support

RFC 1572 style USERVAR variables have been defined to allow a compliant Telnet client more control over the Telnet server virtual device on the AS/400. These USERVAR's allow the client Telnet to create or select a previously created virtual device. If the virtual device does not exist and must be created, then the USERVAR variables are used to create and initialize the device attributes. If the virtual device already exists, the device attributes are modified. The USERVAR's defined to accomplish this are: USERVAR VALUE EXAMPLE DESCRIPTION -------- ---------------- ---------------- ------------------- DEVNAME us-ascii char(x) MYDEVICE07 Display device name KBDTYPE us-ascii char(3) USB Keyboard type CODEPAGE us-ascii char(y) 437 Code page CHARSET us-ascii char(y) 1212 Character set x - up to a maximum of 10 characters y - up to a maximum of 5 characters For a description of the KBDTYPE, CODEPAGE and CHARSET parameters and their permissible values, refer to Chapter 8 in the Communications Configuration Reference [5] and also to Appendix C in National Language Support [16]. The CODEPAGE and CHARSET USERVAR's must be associated with a KBDTYPE USERVAR. If either CODEPAGE or CHARSET are sent without KBDTYPE, they will default to system values. A default value for KBDTYPE can be sent to force CODEPAGE and CHARSET values to be used.
ToP   noToC   RFC2877 - Page 8
   AS/400 system objects such as device names, user profiles, clear-text
   passwords, programs, libraries, etc. are required to be specified in
   English Upper Case (EUC).  This includes:

     Any letter (A-Z), any number (0-9), special characters (# $ _ @)

   Therefore, where us-ascii is specified for VAR or USERVAR values, it
   is recommended that upper-cased ASCII values be sent, which will be
   converted to EBCDIC by the Telnet server.

   A special case occurs for encrypted passwords (described in the next
   section), where both the initial password and user profile used to
   build the encrypted password must be EBCDIC English Upper Case, in
   order to be properly authenticated by the Telnet server.

5. Enhanced Display Auto-Signon and Password Encryption

Several 5250 Telnet server specific USERVAR's will be defined. One will carry a random seed to be used in Data Encryption Standard (DES) password encryption, and another will carry the encrypted copy of the password. This would use the same 7-step DES-based password substitution scheme as APPC and Client Access. For a description of DES encryption, refer to Federal Information Processing Standards Publications (FIPS) 46-2 [17] and 81 [18], which can be found at the Federal Information Processing Standards Publications link: http://www.itl.nist.gov/div897/pubs/by-num.htm For a description of the 7-step password substitution scheme, refer to these IBM Customer Support FTP Server links: ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.ps ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.ps.Z ftp://ftp.networking.ibm.com/pub/standards/ciw/sig/sec/pwsubciw.zip If encrypted password exchange is not required, clear-text password exchange is permitted using the same USERVAR's defined for encryption. For this case, the random client seed should be set to either an empty value (RFC 1572 preferred method) or to hexadecimal zeros to indicate the password is not encrypted, but is clear-text. It should be noted that security of clear-text password exchange cannot be guaranteed unless the network is physically protected or a trusted network (such as an intranet). If your network is vulnerable to IP address spoofing or directly connected to the Internet, you should engage in encrypted password exchange to validate a clients identity.
ToP   noToC   RFC2877 - Page 9
   Additional VAR's and USERVAR's have also been defined to allow an
   auto-signon user greater control over their startup environment,
   similar to what is supported using the Open Virtual Terminal
   (QTVOPNVT) API [3].

   The standard VAR's supported to accomplish this are:

   VAR        VALUE              EXAMPLE           DESCRIPTION
   --------   ----------------   ----------------  -------------------
   USER       us-ascii char(x)   USERXYZ           User profile name

   x - up to a maximum of 10 characters

   The custom USERVAR's defined to accomplish this are:

   USERVAR       VALUE              EXAMPLE           DESCRIPTION
   --------      ----------------   ----------------  -------------------
   IBMRSEED      binary(8)          8-byte hex field  Random client seed
   IBMSUBSPW     binary(10)         10-byte hex field Substitute password
   IBMCURLIB     us-ascii char(x)   QGPL              Current library
   IBMIMENU      us-ascii char(x)   MAIN              Initial menu
   IBMPROGRAM    us-ascii char(x)   QCMD              Program to call

   x - up to a maximum of 10 characters

   In order to communicate the server random seed value to the client,
   the server will request a USERVAR name made up of a fixed part (the 8
   characters "IBMRSEED" immediately followed by an 8-byte hexadecimal
   variable part, which is the server random seed.  The client generates
   its own 8-byte random seed value, and uses both seeds to encrypt the
   password.  Both the encrypted password and the client random seed
   value are then sent to the server for authentication.  RFC 1572 rules
   will need to be adhered to when transmitting the client random seed
   and substituted password values to the server.  Specifically, since a
   typical environment string is a variable length hexadecimal field,
   the hexadecimal fields are required to be escaped and/or byte stuffed
   according to the RFC 854 [8], where any single byte could be mis-
   construed as a Telnet IAC or other Telnet option negotiation control
   character.  The client must escape and/or byte stuff any bytes which
   could be seen as a RFC 1572 [13] option, specifically VAR, VALUE, ESC
   and USERVAR.
ToP   noToC   RFC2877 - Page 10
   The following illustrates the encrypted case:

   AS/400 Telnet server             Enhanced Telnet client
   --------------------------       -------------------------------
   IAC DO NEW-ENVIRON          -->
                               <--  IAC WILL NEW-ENVIRON
   IAC SB NEW-ENVIRON SEND
   USERVAR "IBMRSEEDxxxxxxxx"
   USERVAR "IBMSUBSPW"
   VAR USERVAR IAC SE          -->
                                    IAC SB NEW-ENVIRON IS
                                    VAR "USER" VALUE "DUMMYUSR"
                                    USERVAR "IBMRSEED" VALUE "yyyyyyyy"
                                    USERVAR "IBMSUBSPW" VALUE "zzzzzzzz"
                               <--  IAC SE
                                .
                                .
   (other negotiations)         .

   In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
   seed, "yyyyyyyy" is an 8-byte hexadecimal random client seed and
   "zzzzzzzz" is an 8-byte hexadecimal encrypted password.  If the
   password is not valid, then the sign-on panel is displayed.  If the
   password is expired, then the Change Password panel is displayed.

   Actual bytes transmitted in the above example are shown in hex below,
   where the server seed is "7D3E488F18080404", the client seed is
   "4E4142334E414233" and the encrypted password is "DFB0402F22ABA3BA".
   The user profile used to generate the encrypted password is
   "44554D4D59555352" (DUMMYUSR), with a clear-text password of
   "44554D4D595057" (DUMMYPW).

   AS/400 Telnet server             Enhanced Telnet client
   --------------------------       -------------------------
   FF FD 27                    -->
                               <--  FF FB 27
   FF FA 27 01 03 49 42 4D
   52 53 45 45 44 7D 3E 48
   8F 18 08 04 04 03 49 42
   4D 53 55 42 53 50 57 03
   00 FF F0                    -->
                                    FF FA 27 00 00 55 53 45
                                    52 01 44 55 4D 4D 59 55
                                    53 52 03 49 42 4D 52 53
                                    45 45 44 01 4E 41 42 33
                                    4E 41 42 33 03 49 42 4D
ToP   noToC   RFC2877 - Page 11
                                    53 55 42 53 50 57 01 DF
                                    B0 40 2F 22 AB A3 BA FF
                               <--  F0

   The following illustrates the clear-text case:

   AS/400 Telnet server             Enhanced Telnet client
   --------------------------       -------------------------
   IAC DO NEW-ENVIRON          -->
                               <--  IAC WILL NEW-ENVIRON
   IAC SB NEW-ENVIRON SEND
   USERVAR "IBMRSEEDxxxxxxxx"
   USERVAR "IBMSUBSPW"
   VAR USERVAR IAC SE          -->
                                    IAC SB NEW-ENVIRON IS
                                    VAR "USER" VALUE "DUMMYUSR"
                                    USERVAR "IBMRSEED" VALUE
                                    USERVAR "IBMSUBSPW" VALUE "yyyyyyyy"
                               <--  IAC SE
                                .
                                .
   (other negotiations)         .

   In this example, "xxxxxxxx" is an 8-byte hexadecimal random server
   seed, "yyyyyyyyyy" is a 10-byte us-ascii client clear-text password.
   If the password has expired, then the sign-on panel is displayed.

   Actual bytes transmitted in the above example are shown in hex below,
   where the server seed is "7D3E488F18080404", the client seed is empty
   and the clear-text password is "44554D4D595057" (DUMMYPW).  The user
   profile used is "44554D4D59555352" (DUMMYUSR).

   AS/400 Telnet server             Enhanced Telnet client
   --------------------------       -------------------------
   FF FD 27                    -->
                               <--  FF FB 27
   FF FA 27 01 03 49 42 4D
   52 53 45 45 44 7D 3E 48
   8F 18 08 04 04 03 49 42
   4D 53 55 42 53 50 57 03
   00 FF F0                    -->
                                    FF FA 27 00 00 55 53 45
                                    52 01 44 55 4D 4D 59 55
                                    53 52 03 49 42 4D 52 53
                                    45 45 44 01 03 49 42 4D
                                    53 55 42 53 50 57 01 44
                               <--  55 4D 4D 59 50 57 FF F0
ToP   noToC   RFC2877 - Page 12

5.1 Password Substitutes Processing

Both APPC and Client Access use well-known DES encryption algorithms to create encrypted passwords. A Network Station or Enhanced Client can generate compatible encrypted passwords if they follow these steps, details of which can be found in the Federal Information Processing Standards 46-2 [17]. 1. Padded_PW = Left justified user password padded to the right with '40'X to 8 bytes. The users password must be left justified in an 8 byte variable and padded to the right with '40'X up to an 8 byte length. If the users password is 8 bytes in length, no padding would occur. For computing password substitutes for passwords of length 9 and 10 see section "Handling passwords of length 9 and 10" below. Passwords less than 1 byte or greater than 10 bytes in length are not valid. Please note, if password is not in EBCDIC, it must be converted to EBCDIC uppercase. 2. XOR_PW = Padded_PW xor '5555555555555555'X The padded password is Exclusive OR'ed with 8 bytes of '55'X. 3. SHIFT_RESULT = XOR_PW << 1 The entire 8 byte result is shifted 1 bit to the left; the leftmost bit value is discarded, and the rightmost bit value is cleared to 0. 4. PW_TOKEN = DES_ECB_mode(SHIFT_RESULT, /* key */ userID_in_EBCDIC_uppercase /* data */ ) This shifted result is used as key to the Data Encryption Standard (Federal Information Processing Standards 46-2 [17]) to encipher the user identifier. When the user identifier is less than 8 bytes, it is left justified in an 8 byte variable and padded to the right with '40'X. When the user identifier is 9 or 10 bytes, it is first padded to the right with '40'X to a length of 10 bytes. Then bytes 9 and 10 are "folded" into bytes 1-8 using the following algorithm: Bit 0 is the high-order bit (i.e. has value of '80'X). Byte 1, bits 0 and 1 are replaced with byte 1, bits 0 and 1 Exclusive OR'ed with byte 9, bits 0 and 1. Byte 2, bits 0 and 1 are replaced with byte 2, bits 0 and 1 Exclusive OR'ed with byte 9, bits 2 and 3.
ToP   noToC   RFC2877 - Page 13
        Byte 3, bits 0 and 1 are replaced with byte 3, bits 0 and 1
        Exclusive OR'ed with byte 9, bits 4 and 5.
        Byte 4, bits 0 and 1 are replaced with byte 4, bits 0 and 1
        Exclusive OR'ed with byte 9, bits 6 and 7.
        Byte 5, bits 0 and 1 are replaced with byte 5, bits 0 and 1
        Exclusive OR'ed with byte 10, bits 0 and 1.
        Byte 6, bits 0 and 1 are replaced with byte 6, bits 0 and 1
        Exclusive OR'ed with byte 10, bits 2 and 3.
        Byte 7, bits 0 and 1 are replaced with byte 7, bits 0 and 1
        Exclusive OR'ed with byte 10, bits 4 and 5.
        Byte 8, bits 0 and 1 are replaced with byte 8, bits 0 and 1
        Exclusive OR'ed with byte 10, bits 6 and 7.

      User identifier greater than 10 bytes or less than 1 byte are not
      the result of this encryption id known as PW_TOKEN in the paper.

   5. Increment PWSEQs and store it.

      Each LU must maintain a pair of sequence numbers for ATTACHs sent
      and received on each session.  Each time an ATTACH is generated,
      (and password substitutes are in use on the session) the sending
      sequence number, PWSEQs, is incremented and saved for the next
      time.  Both values are set to zero at BIND time.  So the first use
      of PWSEQs has the value of 1, and increases by one with each use.
      A new field is added to the ATTACH to carry this sequence number.
      However, in certain error conditions, it is possible for the
      sending side to increment the sequence number and the receiver may
      not increment it.  When the sender sends a subsequent ATTACH, the
      receiver will detect a missing sequence.  This is allowed.
      However the sequence number received must always be larger than
      the previous one, even if some are missing.

      The maximum number of consecutive missing sequence numbers allowed
      is 16.  If this is exceeded, the session is unbound with a
      protocol violation.

      Note: The sequence number must be incremented for every ATTACH
      sent.  However, the sequence number field is only required to be
      included in the FMH5 if a password substitute is sent (byte 4, bit
      3 on).

   6. RDrSEQ = RDr + PWSEQs  /* RDr is server seed. */

      The current value of PWSEQs is added to RDr, the random value
      received from the partner LU on this session, yielding RDrSEQ,
      essentially a predictably modified value of the random value
      received from the partner LU at BIND time.
ToP   noToC   RFC2877 - Page 14
   7. PW_SUB = DES_CBC_mode(PW_TOKEN,        /* key      */
                            (RDrSEQ,         /* 8 bytes  */
                             RDs,            /* 8 bytes  */
                             ID xor RDrSEQ,  /* 16 bytes */
                             PWSEQs,         /* 8 bytes  */
                             )               /* data     */
                            )

       The PW_TOKEN is used as a key to the DES function to generate
       a 8 bytes value for the following string of inputs.  The DES
       CBC mode Initialization Vector (IV) used is 8 bytes of '00'X.

         RDrSEQ: the random data value received from the partner LU
                 plus the sequence number.

         RDs:    the random data value sent to the partner LU on BIND
                 for this session.

         A 16 byte value created by:

                 - padding the user identifier with '40'X to a
                   length of 16 bytes.

                 - Exclusive OR the two 8 byte halves of the padded
                   user identifier with the RDrSEQ value.

                 Note: User ID must first be converted to EBCDIC
                 upper case.

         PWSEQs: the sequence number.

      This is similar to the process used on LU-LU verification as
      described in the Enhanced LU-LU Bind Security.  The resulting
      enciphered random data is the 'password substitute'.

5.2 Handling passwords of length 9 and 10

1. Generate PW_TOKENa by using characters 1 to 8 of the password and steps 1-4 from the previous section. 2. Generate PW_TOKENb by using characters 9 and 10 and steps 1-4 from the previous section. In this case Padded_PW from step 1 will be characters 9 and 10 padded to the right with '40'X, for a total length of 8. 3. PW_TOKEN = PW_TOKENa xor PW_TOKENb
ToP   noToC   RFC2877 - Page 15
   4. Now compute PW_SUB by performing steps 5-7 from the previous
      section.

5.3 Example Password Substitute Calculation

ID: USER123 Password: ABCDEFG Server seed: '7D4C2319F28004B2'X Client seed: '08BEF662D851F4B1'X PWSEQs: 1 (PWSEQs is a sequence number needed in the 7-step encryption, and it is always one) Encrypted Password should be : '5A58BD50E4DD9B5F'X

6. Device Name Collision Processing

Device name collision occurs when a Telnet client sends the Telnet server a virtual device name that it wants to use, but that device is already in use on the server. When this occurs, the Telnet server sends a request to the client asking it to try another device name. The environment option negotiation uses the USERVAR name of DEVNAME to communicate the virtual device name. The following shows how the Telnet server will request the Telnet client to send a different DEVNAME when device name collision occurs. AS/400 Telnet server Enhanced Telnet client -------------------------- ------------------------- IAC SB NEW-ENVIRON SEND VAR USERVAR IAC SE --> Server requests all environment variables be sent. IAC SB NEW-ENVIRON IS USERVAR "DEVNAME" VALUE "MYDEVICE1" USERVAR "xxxxx" VALUE "xxx" ... <-- IAC SE Client sends all environment variables, including DEVNAME. Server tries to select device MYDEVICE1. If the device is already in use, server requests DEVNAME be sent again. IAC SB NEW-ENVIRON SEND USERVAR "DEVNAME" IAC SE -->
ToP   noToC   RFC2877 - Page 16
   Server sends a request for a single environment variable: DEVNAME

                                    IAC SB NEW-ENVIRON IS USERVAR
                              <--   "DEVNAME" VALUE "MYDEVICE2" IAC SE

   Client sends one environment variable, calculating a new value of
   MYDEVICE2.  If MYDEVICE2 is different from the last request, then
   server tries to select device MYDEVICE2, else server disconnects
   client.  If MYDEVICE2 is also in use, server will send DEVNAME
   request again, and keep doing so until it receives a device that is
   not in use, or the same device name twice in row.

7. Enhanced Printer Emulation Support

RFC 1572 style USERVAR variables have been defined to allow a compliant Telnet client more control over the Telnet server virtual device on the AS/400. These USERVAR's allow the client Telnet to select a previously created virtual device or auto-create a new virtual device with requested attributes. This makes the enhancements available to any Telnet client that chonoses to support the new negotiations. The USERVAR's defined to accomplish this are: USERVAR VALUE EXAMPLE DESCRIPTION ------------- ---------------- ---------------- ------------------- DEVNAME us-ascii char(x) PRINTER1 Printer device name IBMIGCFEAT us-ascii char(6) 2424J0 IGC feature (DBCS) IBMMSGQNAME us-ascii char(x) QSYSOPR *MSGQ name IBMMSGQLIB us-ascii char(x) QSYS *MSGQ library IBMFONT us-ascii char(x) 12 Font IBMFORMFEED us-ascii char(1) C | U | A Formfeed IBMTRANSFORM us-ascii char(1) 1 | 0 Transform IBMMFRTYPMDL us-ascii char(x) *IBM42023 Mfg. type and model IBMPPRSRC1 binary(1) 1-byte hex field Paper source 1 IBMPPRSRC2 binary(1) 1-byte hex field Paper source 2 IBMENVELOPE binary(1) 1-byte hex field Envelope hopper IBMASCII899 us-ascii char(1) 1 | 0 ASCII 899 support IBMWSCSTNAME us-ascii char(x) *NONE WSCST name IBMWSCSTLIB us-ascii char(x) *LIBL WSCST library x - up to a maximum of 10 characters The "IBM" prefix on the USERVAR's denotes AS/400 specific attributes. The DEVNAME USERVAR is used both for displays and printers. The IBMFONT and IBMASCII899 are used only for SBCS environments.
ToP   noToC   RFC2877 - Page 17
   For a description of most of these parameters (drop the "IBM" from
   the USERVAR) and their permissible values, refer to Chapter 8 in the
   Communications Configuration Reference [5].

   The IBMIGCFEAT supports the following variable DBCS language
   identifiers in position 5 (positions 1-4 must be '2424', position 6
   must be '0'):

        'J' = Japanese              'K' = Korean
        'C' = Traditional Chinese   'S' = Simplified Chinese

   The IBMTRANSFORM and IBMASCII899 values correspond to:

        '1' = Yes  '2' = No

   The IBMFORMFEED values correspond to:

        'C' = Continuous  'U' = Cut  'A' = Autocut

   The IBMPPRSRC1, IBMPPRSRC2 and IBMENVELOPE custom USERVAR's do not
   map directly to their descriptions in Chapter 8 in the Communications
   Configuration Reference [5].  To map these, use the index listed
   here:

   IBMPPRSRC1    HEX     IBMPPRSRC2    HEX     IBMENVELOPE    HEX
   ----------   -----    ----------   -----    -----------   -----
   *NONE        'FF'X    *NONE        'FF'X    *NONE         'FF'X
   *MFRTYPMDL   '00'X    *MFRTYPMDL   '00'X    *MFRTYPMDL    '00'X
   *LETTER      '01'X    *LETTER      '01'X    *B5           '06'X
   *LEGAL       '02'X    *LEGAL       '02'X    *MONARCH      '09'X
   *EXECUTIVE   '03'X    *EXECUTIVE   '03'X    *NUMBER9      '0A'X
   *A4          '04'X    *A4          '04'X    *NUMBER10     '0B'X
   *A5          '05'X    *A5          '05'X    *C5           '0C'X
   *B5          '06'X    *B5          '06'X    *DL           '0D'X
   *CONT80      '07'X    *CONT80      '07'X
   *CONT132     '08'X    *CONT132     '08'X
   *A3          '0E'X    *A3          '0E'X
   *B4          '0F'X    *B4          '0F'X
   *LEDGER      '10'X    *LEDGER      '10'X

   Note 1:  For IBMPPRSRC2, *CONT80 and *CONT132 support starts at V3R7.

   Note 2:  For IBMPPRSRC1 and IBMPPRSRC2, *A3, *B4 and *LEDGER support
   starts at V3R7.
ToP   noToC   RFC2877 - Page 18

8. Telnet Printer Terminal Types

New Telnet options are defined for the printer pass-through mode of operation. To enable printer pass-through mode, both the client and server must agree to at least support the Transmit-Binary, End-Of- Record, and Terminal-Type Telnet options. The following are new terminal types for printers: TERMINAL-TYPE DESCRIPTION ------------- ------------------- IBM-5553-B01 Double-Byte printer IBM-3812-1 Single-Byte printer Specific characteristics of the IBM-5553-B01 or IBM-3812-1 printers are specified through the USERVAR IBMMFRTYPMDL, which specifies the manufacturer type and model. An example of a typical negotiation process to establish printer pass-through mode of operation is shown below. In this example, the server initiates the negotiation by sending the DO TERMINAL-TYPE request. For DBCS environments, if IBMTRANSFORM is set to 1 (use Host Print Transform), then the virtual device created is 3812, not 5553. Therefore, IBM-3812-1 should be negotiated for TERMINAL-TYPE, and not IBM-5553-B01. AS/400 Telnet server Enhanced Telnet client -------------------------- -------------------------- IAC DO NEW-ENVIRON --> <-- IAC WILL NEW-ENVIRON IAC SB NEW-ENVIRON SEND VAR USERVAR IAC SE --> IAC SB NEW-ENVIRON IS USERVAR "DEVNAME" VALUE "PCPRINTER" USERVAR "IBMMSGQNAME" VALUE "QSYSOPR" USERVAR "IBMMSGQLIB" VALUE "*LIBL" USERVAR "IBMTRANSFORM" VALUE "0" USERVAR "IBMFONT" VALUE "12" USERVAR "IBMFORMFEED" VALUE "C" USERVAR "IBMPPRSRC1" VALUE ESC '01'X USERVAR "IBMPPRSRC2" VALUE '04'X USERVAR "IBMENVELOPE" VALUE IAC 'FF'X <-- IAC SE IAC DO TERMINAL-TYPE --> <-- IAC WILL TERMINAL-TYPE IAC SB TERMINAL-TYPE SEND IAC SE -->
ToP   noToC   RFC2877 - Page 19
                                   IAC SB TERMINAL-TYPE IS IBM-3812-1
                              <--  IAC SE
   IAC DO BINARY              -->
                              <--  IAC WILL BINARY
   IAC DO EOR                 -->
                              <--  IAC WILL EOR

   Some points about the above example.  The IBMPPRSRC1 value requires
   escaping the value using ESC according to RFC 1572 [13].  The
   IBMPPRSRC2 does not require an ESC character since '04'X has no
   conflict with RFC 1572 options.  Finally, to send 'FF'X for the
   IBMENVELOPE value, escape the 'FF'X value by using another 'FF'X
   (called "doubling"), so as not to have the value interpreted as a
   Telnet character per RFC 854 [8].

   Actual bytes transmitted in the above example are shown in hex below.

   AS/400 Telnet server             Enhanced Telnet client
   --------------------------       --------------------------
   FF FD 27                    -->
                               <--  FF FB 27
   FF FA 27 01 00 03 FF F0     -->
                                    FF FA 27 00 03 44 45 56
                                    4E 41 4D 45 01 50 43 50
                                    52 49 4E 54 45 52 03 49
                                    42 4D 4D 53 47 51 4E 41
                                    4D 45 01 51 53 59 53 4F
                                    50 52 03 49 42 4D 4D 53
                                    47 51 4C 49 42 01 2A 4C
                                    49 42 4C 03 49 42 4D 54
                                    52 41 4E 53 46 4F 52 4D
                                    01 30 03 49 42 4D 46 4F
                                    4E 54 01 31 32 03 49 42
                                    4D 46 4F 52 4D 46 45 45
                                    44 01 43 03 49 42 4D 50
                                    50 52 53 52 43 31 01 02
                                    01 03 49 42 4D 50 50 52
                                    53 52 43 32 01 04 03 49
                                    42 4D 45 4E 56 45 4C 4F
                               <--  50 45 01 FF FF FF F0
   FF FD 18                    -->
                               <--  FF FB 18
   FF FA 18 01 FF F0           -->
                                    FF FA 18 00 49 42 4D 2D
                               <--  33 38 31 32 2D 31 FF F0
   FF FD 00                    -->
                               <--  FF FB 00
   FF FD 19                    -->
ToP   noToC   RFC2877 - Page 20
                                    FF FB 19

9. Telnet Printer Startup Response Record for Printer Emulators

Once Telnet negotiation for a 5250 pass-through mode is completed, the 5250 Telnet server will initiate a virtual printer power-on sequence on behalf of the Telnet client. The Telnet server will supply a Startup Response Record to the Telnet client with the status of the printer power-on sequence, indicating success or failure of the virtual printer power-on sequence. This section shows an example of two Startup Response Records. The source device is a type 3812 model 01 printer with name "PCPRINTER" on the target system "TARGET". Figure 1 shows an example of a successful response; Figure 2 shows an example of an error response.

9.1 Example of a Success Response Record

The response record in Figure 1 was sent by an AS/400 at Release V4R2. It is an example of the target sending back a successful Startup Response Record. +------------------------------------------------------------------+ | +----- Pass-Through header | | | +--- Response data | | | | +---- Start diagnostic information| | | | | | | +----------++----------++--------------------------------------- | | | || || | | 004912A090000560060020C0003D0000C9F9F0F2E3C1D9C7C5E34040D7C3D7D9 | | | | T A R G E T P C P R | | +------+ | | Response Code (I902) | | | | ---------------------------------------------------------------- | | | | C9D5E3C5D9400000000000000000000000000000000000000000000000000000 | | I N T E R | | | | +------- End of diagnostic information | | | | | -----------------+ | | | | | 000000000000000000 | +------------------------------------------------------------------+ Figure 1. Example of a success response record.
ToP   noToC   RFC2877 - Page 21
   - '0049'X = Length pass-through data, including this length field
   - '12A0'X = GDS LU6.2 header
   - '90000560060020C0003D0000'X = Fixed value fields
   - 'C9F9F0F2'X                 = Response Code (I902)
   - 'E3C1D9C7C5E34040'X         = System Name (TARGET)
   - 'D7C3D7D9C9D5E3C5D940'X     = Object Name (PCPRINTER)

9.2 Example of an Error Response Record

The response record in Figure 2 is one that reports an error. The virtual device named "PCPRINTER", is not available on the target system "TARGET", because the device is not available. You would normally see this error if the printer was already assigned to another Telnet session. +------------------------------------------------------------------+ | +----- Pass-Through header | | | +--- Response data | | | | +---- Start diagnostic information| | | | | | | +----------++----------++--------------------------------------- | | | || || | | 004912A09000056006008200003D0000F8F9F0F2E3C1D9C7C5E34040D7C3D7D9 | | | | T A R G E T P C P R | | +------+ | | Response Code (8902) | | | | ---------------------------------------------------------------- | | | | C9D5E3C5D9400000000000000000000000000000000000000000000000000000 | | I N T E R | | | | +------- End of diagnostic information | | | | | -----------------+ | | | | | 000000000000000000 | +------------------------------------------------------------------+ Figure 2. Example of an error response record. - '0049'X = Length pass-through data, including this length field - '12A0'X = GDS LU6.2 header - '90000560060020C0003D0000'X = Fixed value fields - 'F8F9F0F2'X = Response Code (8902) - 'E3C1D9C7C5E34040'X = System Name (TARGET) - 'D7C3D7D9C9D5E3C5D940'X = Object Name (PCPRINTER)
ToP   noToC   RFC2877 - Page 22

9.3 Response Codes

The Start-Up Response Record success response codes: CODE DESCRIPTION ---- ------------------------------------------------------ I901 Virtual device has less function than source device I902 Session successfully started I906 Automatic sign-on requested, but not allowed. Session still allowed; a sign-on screen will be coming. The Start-Up Response Record error response codes: CODE DESCRIPTION ---- ------------------------------------------------------ 2702 Device description not found. 2703 Controller description not found. 2777 Damaged device description. 8901 Device not varied on. 8902 Device not available. 8903 Device not valid for session. 8906 Session initiation failed. 8907 Session failure. 8910 Controller not valid for session. 8916 No matching device found. 8917 Not authorized to object. 8918 Job canceled. 8920 Object partially damaged. 8921 Communications error. 8922 Negative response received. 8923 Start-up record built incorrectly. 8925 Creation of device failed. 8928 Change of device failed. 8929 Vary on or vary off failed. 8930 Message queue does not exist. 8934 Start-up for S/36 WSF received. 8935 Session rejected. 8936 Security failure on session attempt. 8937 Automatic sign-on rejected. 8940 Automatic configuration failed or not allowed. I904 Source system at incompatible release.
ToP   noToC   RFC2877 - Page 23

10. Printer Steady-State Pass-Through Interface

The information in this section applies to the passthrough session after the receipt of startup confirmation records is complete. Following is the printer header interface used by Telnet. +------------------------------------------------------------------+ | +-- Length of structure (LLLL) | | | | | | +-- GDS identifier | | | | | | | | +-- Data flow record | | | | | | | | | | +-- Length of pass-through specific header (LL) | | | | | | | | | | | | +-- Flags | | | | | | | | | | | | | | +-- Printer operation code | | | | | | | | | | | | | | | | +-- Diagnostic field - zero pad to| | | | | | | | | LL specified | | | | | | | | | | | | | | | | | | +-- Printer data | | | | | | | | | | | | +--+ +--+ +--+ ++ +--+ ++ +----------+ +----------------+ | | | | | | | | || | | || | | | | | | xxxx 12A0 xxxx xx xxxx xx xxxxxxxxxxxx ... print data ... | | | +------------------------------------------------------------------+ Figure 3. Layout of the printer pass-through header BYTES 0-1: Length of structure including this field (LLLL) BYTES 2-3: GDS Identifier ('12A0'X) BYTE 4-5: Data flow record This field contains flags that describe what type of data pass-through should expect to find following this header. Generally, bits 0-2 in the first byte are mutually exclusive (that is, if one of them is set to ' 1'B, the rest will be set to '0'B.) The bits, and their meanings follow.
ToP   noToC   RFC2877 - Page 24
                BIT       DESCRIPTION

                0         Start-Up confirmation
                1         Termination record
                2         Start-Up Record
                3         Diagnostic information included
                4 - 5     Reserved
                6         Reserved
                7         Printer record
                8 - 13    Reserved
                14        Client-originated (inbound) printer record
                15        Server-originated (outbound) printer record

   BYTE 6:      Length printer pass-through header including this
                field (LL)

   BYTES 7-8:   Flags

     BYTE 7 BITS:  xxxx x111 --> Reserved
                   xxxx 1xxx --> Last of chain
                   xxx1 xxxx --> First of chain
                   xx1x xxxx --> Printer now ready
                   x1xx xxxx --> Intervention Required
                   1xxx xxxx --> Error Indicator

     BYTE 8 BITS:  xxxx xxxx --> Reserved

   BYTE 9:      Printer operation code

                '01'X  Print/Print complete
                '02'X  Clear Print Buffers

   BYTE 10-LL:  Diagnostic information (1)

     If BYTE 7 = xx1x xxxx then bytes 10-LL may contain:
        Printer ready                C9 00 00 00 02

     If BYTE 7 = x1xx xxxx then bytes 10-LL may contain: (2)
        Command/parameter not valid  C9 00 03 02 2x
        Print check                  C9 00 03 02 3x
        Forms check                  C9 00 03 02 4x
        Normal periodic condition    C9 00 03 02 5x
        Data stream error            C9 00 03 02 6x
        Machine/print/ribbon check   C9 00 03 02 8x

     If BYTE 7 = 1xxx xxxx then bytes 10-LL may contain: (3)
        Cancel                       08 11 02 00
        Invalid print parameter      08 11 02 29
ToP   noToC   RFC2877 - Page 25
        Invalid print command        08 11 02 28

   Diagnostic information notes:

   1.  LL is the length of the structure defined in Byte 6.  If no
       additional data is present, the remainder of the structure must
       be padded with zeroes.

   2.  These are printer SIGNAL commands.  Further information on these
       commands may be obtained from the 5494 Remote Control Unit
       Functions Reference guide [2].  Refer to your AS/400 printer
       documentation for more specific information on these data stream
       exceptions.  Some 3812 and 5553 errors that may be seen:

       Machine check              C9 00 03 02 11
       Graphics check             C9 00 03 02 26
       Print check                C9 00 03 02 31
       Form jam                   C9 00 03 02 41
       Paper jam                  C9 00 03 02 47
       End of forms               C9 00 03 02 50
       Printer not ready          C9 00 03 02 51
       Data stream - class 1      C9 00 03 02 66 loss of text
       Data stream - class 2      C9 00 03 02 67 text appearance
       Data stream - class 3      C9 00 03 02 68 multibyte control error
       Data stream - class 4      C9 00 03 02 69 multibyte control parm
       Cover unexpectedly open    C9 00 03 02 81
       Machine check              C9 00 03 02 86
       Machine check              C9 00 03 02 87
       Ribbon check               C9 00 03 02 88

   3.  These are printer negative responses.  Further information on
       these commands may be obtained from the 5494 Remote Control Unit
       Functions Reference guide [2].

       The print data will start in byte LL+1.

10.1 Example of a Print Record

Figure 4 shows the server sending the client data with a print record. This is normally seen following receipt of a Success Response Record, such as the example in Figure 1.
ToP   noToC   RFC2877 - Page 26
  +--------------------------------------------------------------------+
  |   +-- Length of structure (LLLL)                                   |
  |   |    +-- GDS identifier                                          |
  |   |    |    +-- Data flow record                                   |
  |   |    |    |   +-- Length of pass-through specific header (LL)    |
  |   |    |    |   |   +-- Flags                                      |
  |   |    |    |   |   |   +-- Printer operation code                 |
  |   |    |    |   |   |   |      +-- Zero pad to LL specified (0A)   |
  |   |    |    |   |   |   |      |            +-- Printer data       |
  |   |    |    |   |   |   |      |            |                      |
  | +--+ +--+ +--+ ++ +--+ ++ +----------+ +---------------------------|
  | |  | |  | |  | || |  | || |          | |                           |
  | 0085 12A0 0101 0A 1800 01 000000000000 34C4012BD20345FF2BD2044C0002|
  |                                                                    |
  | ------------------------------------------------------------       |
  |                                                                    |
  | 2BD2040D00002BD20A8501010201030204022BD20309022BD2061100014A       |
  |                                                                    |
  | ------------------------------------------------------------       |
  |                                                                    |
  | 402BD20601010000012BD306F60000FFFF2BD20A48000001000000010100       |
  |                                                                    |
  | ------------------------------------------------------------       |
  |                                                                    |
  | 2BD10705000B0090012BD2044900F02BD206404A403DE02BD2041500F034       |
  |                                                                    |
  |    end of printer data                                             |
  | -------------------------+                                         |
  |                          |                                         |
  | C4012BD10381FF002BC8034001                                         |
  +--------------------------------------------------------------------+
   Figure 4. Server sending client data with a print record

   - '0085'X         = Logical record length, including this byte (LLLL)
   - '12A0'X         = GDS LU6.2 header
   - '0101'X         = Data flow record (server to client)
   - '0A'X           = Length of pass-through specific header (LL)
   - '1800'X         = First of chain / Last of chain indicators
   - '01'X           = Print
   - '000000000000'X = Zero pad header to LL specified
   - '34C401'X       = First piece of data for spooled data
   - Remainder is printer data/commands/orders
ToP   noToC   RFC2877 - Page 27

10.2 Example of a Print Complete Record

Figure 5 shows the client sending the server a print complete record. This would normally follow receipt of a print record, such as the example in Figure 4. This indicates successful completion of a print request. +-------------------------------------------------------------------+ | +-- Length of structure (LLLL) | | | +-- GDS identifier | | | | +-- Data flow record | | | | | +-- Length of pass-through specific header (LL) | | | | | | +-- Flags | | | | | | | +-- Printer operation code | | | | | | | | | | +--+ +--+ +--+ ++ +--+ ++ | | | | | | | | || | | || | | 000A 12A0 0102 04 0000 01 | +-------------------------------------------------------------------+ Figure 5. Client sending server a print complete record - '000A'X = Logical record length, including this byte (LLLL) - '12A0'X = GDS LU6.2 header - '0102'X = Data flow response record (client to server) - '04'X = Length of pass-through specific header (LL) - '0000'X = Good Response - '01'X = Print Complete

10.3 Example of a Null Print Record

Figure 6 shows the server sending the client a null print record. The null print record is the last print command the server sends to the client for a print job, and indicates to the printer there is no more data. The null data byte '00'X is optional, and in some cases may be omitted (in particular, this scenario occurs in DBCS print streams). This example would normally follow any number of print records, such as the example in Figure 4. This indicates successful completion of a print job. The client normally responds to this null print record with another print complete record, such as in Figure 5.
ToP   noToC   RFC2877 - Page 28
   +------------------------------------------------------------------+
   |   +-- Length of structure (LLLL)                                 |
   |   |    +-- GDS identifier                                        |
   |   |    |    +-- Data flow record                                 |
   |   |    |    |   +-- Length of pass-through specific header (LL)  |
   |   |    |    |   |   +-- Flags                                    |
   |   |    |    |   |   |   +-- Printer operation code               |
   |   |    |    |   |   |   |      +-- Zero pad to LL specified (0A) |
   |   |    |    |   |   |   |      |        +-- Printer data         |
   |   |    |    |   |   |   |      |        |                        |
   | +--+ +--+ +--+ ++ +--+ ++ +----------+ ++                        |
   | |  | |  | |  | || |  | || |          | ||                        |
   | 0011 12A0 0101 0A 0800 01 000000000000 00                        |
   +------------------------------------------------------------------+
    Figure 6. Server sending client a null print record

   - '0011'X         = Logical record length, including this byte
   - '12A0'X         = GDS LU6.2 header
   - '0101'X         = Data flow record
   - '0A'X           = Length of pass-through specific header (LL)
   - '0800'X         = Last of Chain
   - '01'X           = Print
   - '000000000000'X = Zero pad header to LL specified
   - '00'X           = Null data byte

11. End-to-End Print Example

The next example shows a full print exchange between a Telnet client and server for a 526 byte spooled file. Selective translation of the hexadecimal streams into 1) Telnet negotiations and 2) ASCII/EBCDIC characters are done to aid readability. Telnet negotiations are delimited by '(' and ')' parenthesis characters; ASCII/EBCDIC conversions are bracketed by '|' vertical bar characters. AS/400 Telnet server Enhanced Telnet client ------------------------------- --------------------------------- FFFD27 --> (IAC DO NEW-ENVIRON) <-- FFFB27 (IAC WILL NEW-ENVIRON) FFFD18FFFA270103 49424D5253454544 7EA5DFDDFD300404 0003FFF0 --> (IAC DO TERMINAL-TYPE IAC SB NEW-ENVIRON SEND USERVAR
ToP   noToC   RFC2877 - Page 29
 IBMRSEED xxxxxxxx VAR USERVAR
 IAC SE)

                                 <-- FFFB18

                                     (IAC WILL TERMINAL-TYPE)

 FFFA1801FFF0                    -->

 (IAC SB TERMINAL-TYPE SEND IAC
  SE)

                                     FFFA27000349424D 52534545447EA5DF
                                     DDFD300404000344 45564E414D450144
                                     554D4D5950525403 49424D4D5347514E
                                     414D450151535953 4F50520349424D4D
                                     5347514C4942012A 4C49424C0349424D
                                     464F4E5401313103 49424D5452414E53
                                     464F524D01310349 424D4D4652545950
                                     4D444C012A485049 490349424D505052
                                     5352433101020103 49424D5050525352
                                     433201040349424D 454E56454C4F5045
                                     01FFFF0349424D41 5343494938393901
                                 <-- 30FFF0

                                     (IAC SB NEW-ENVIRON IS USERVAR
                                      IBMRSEED xxxxxxxx VAR
                                      USERVAR DEVNAME VALUE DUMMYPRT
                                      USERVAR IBMMSGQNAME VALUE QSYSOPR
                                      USERVAR IBMMSGQLIB VALUE *LIBL
                                      USERVAR IBMFONT VALUE 11
                                      USERVAR IBMTRANSFORM VALUE 1
                                      USERVAR IBMMFRTYPMDL VALUE *HPII
                                      USERVAR IBMPPRSRC1 VALUE ESC '01'X
                                      USERVAR IBMPPRSRC2 VALUE '04'X
                                      USERVAR IBMENVELOPE VALUE IAC
                                      USERVAR IBMASCII899 VALUE 0
                                      IAC SE)

                                 <-- FFFA180049424D2D 333831322D31FFF0

                                     (IAC SB TERMINAL-TYPE IS
                                      IBM-3812-1 IAC SE)
 FFFD19                          -->

 (IAC DO EOR)
                                 <-- FFFB19
ToP   noToC   RFC2877 - Page 30
                                     (IAC WILL EOR)

 FFFB19                          -->

 (IAC WILL EOR)
                                 <-- FFFD19

                                     (IAC DO EOR)
 FFFD00                          -->

 (IAC DO BINARY)
                                 <-- FFFB00

                                     (IAC WILL BINARY)
 FFFB00                          -->

 (IAC WILL BINARY)
                                 <-- FFFD00

                                     (IAC DO BINARY)

 004912A090000560 060020C0003D0000     |       -   {    |
 C9F9F0F2C5D3C3D9 E3D7F0F6C4E4D4D4     |I902ELCRTP06DUMM| (EBCDIC)
 E8D7D9E340400000 0000000000000000     |YPRT            |
 0000000000000000 0000000000000000     |                |
 0000000000000000 00FFEF           --> |                |

 (73-byte startup success response
  record ... IAC EOR)
 00DF12A001010A18 0001000000000000     |                |
 03CD1B451B283130 551B287330703130     |   E (10U (s0p10| (ASCII)
 2E30306831327630 733062303033541B     |.00h12v0s0b003T |
 287330421B266440 1B266C304F1B266C     |(s0B &d@ &l0O &l|
 303038431B266C30 3035431B28733070     |008C &l005C (s0p|
 31372E3130683130 7630733062303030     |17.10h10v0s0b000|
 541B283130551B28 73307031372E3130     |T (10U (s0p17.10|
 6831307630733062 303030541B287330     |h10v0s0b000T (s0|
 421B2664401B266C 314F1B266C303035     |B &d@ &l1O &l005|
 431B287330703137 2E31306831307630     |C (s0p17.10h10v0|
 733062303030541B 266C314F1B287330     |s0b000T &l1O (s0|
 7031372E31306831 3076307330623030     |p17.10h10v0s0b00|
 30541B2873307031 372E313068313076     |0T (s0p17.10h10v|
 3073306230303054 1B266C30303543FF     |0s0b000T &l005C |
 EF                                --> |                |

 (... 223-byte print record ...
  ... first of chain ...
  ... last of chain ... IAC EOR)
ToP   noToC   RFC2877 - Page 31
                                   <-- 000A12A001020400 0001FFEF

                                       (10-byte print complete header)
 031012A001010A10 0001000000000000     |                |
 03FFFF1B451B2831 30551B2873307031     |    E (10U (s0p1| (ASCII)
 372E313068313076 3073306230303054     |7.10h10v0s0b000T|
 1B287330421B2664 401B266C314F1B26     | (s0B &d@ &l1O &|
 6C303035431B266C 31481B266C314F1B     |l005C &l1H &l1O |
 266C3032411B266C 31431B266C303030     |&l02A &l1C &l000|
 38451B266C303038 431B266C30303439     |8E &l008C &l0049|
 461B266130521B26 6C303035430A0A0A     |F &a0R &l005C   |
 0A0A0A0A1B26612B 3030303130561B26     |     &a+00010V &|
 6C303035431B2661 2B30303231364820     |l005C &a+00216H |
 2020202020202020 2020202020202020     |                |
 2020202020205072 696E74204B657920     |      Print Key |
 4F75747075742020 2020202020202020     |Output          |
 2020202020202020 2020202020202020     |                |
 2020202020205061 6765202020310D0A     |      Page   1  |
 1B26612B30303231 3648202020203537     | &a+00216H    57|
 3639535331205634 52334D3020393830     |69SS1 V4R3M0 980|
 373203FFFF392020 2020202020202020     |72   9          |
 202020202020454C 4352545030362020     |      ELCRTP06  |
 2020202020202020 202030332F33312F     |          03/31/|
 3939202031363A33 303A34350D0A1B26     |99  16:30:45   &|
 612B303032313648 0D0A1B26612B3030     |a+00216H   &a+00|
 3231364820202020 446973706C617920     |216H    Display |
 4465766963652020 2E202E202E202E20     |Device  . . . . |
 2E203A2020515041 444556303033510D     |. :  QPADEV003Q |
 0A1B26612B303032 3136482020202055     |  &a+00216H    U|
 73657220202E202E 202E202E202E202E     |ser  . . . . . .|
 202E202E202E202E 203A202052434153     | . . . . :  RCAS|
 54524F0D0A1B2661 2B3030323136480D     |TRO   &a+00216H |
 0A1B26612B303032 313648204D41494E     |  &a+00216H MAIN|
 2020202020202020 2020202020202020     |                |
 2020202020202020 20202041532F3430     |           AS/40|
 30204D61696E204D 656E750D0A1B2661     |0 Main Menu   &a|
 2B30303203FFFF31 3648202020202020     |+002   16H      |
 2020202020202020 2020202020202020     |                |
 2020202020202020 2020202020202020     |                |
 2020202020202020 2020202020202020     |                |
 2020202020202053 797374656D3A2020     |       System:  |
 20454C4352545030 360D0A1B26612B30     | ELCRTP06   &a+0|
 3032313648205365 6C656374206F6E65     |0216H Select one|
 206F662074686520 666F6C6C6F77696E     | of the followin|
 673A0D0A1B26612B 3030323136480D0A     |g:   &a+00216H  |
 1B26612B30303231 3648202020202020     | &a+00216H      |
 312E205573657220 7461736B730D0A1B     |1. User tasks   |
 26612B3030323136 4820202020202032     |&a+00216H      2|
ToP   noToC   RFC2877 - Page 32
 2E204F6666696365 207461736B730D0A     |. Office tasks  |
 1B26612B30303231 36480D0A1B26612B     | &a+00216H   &a+|
 3030323136482020 20202020342E2046     |00216H      4. F|
 696C65732C206C69 627261726965732C     |iles, libraries,|
 20616EFFEF                            | an             |

 (... 784-byte print record ...
  ... first of chain ... IAC EOR)
                                   <-- 000A12A001020400 0001FFEF

                                       (10-byte print complete header)

 020312A001010A00 0001000000000000     |                |
 64206603FFFF6F6C 646572730D0A1B26     |d f   olders   &| (ASCII)
 612B303032313648 0D0A1B26612B3030     |a+00216H   &a+00|
 3231364820202020 2020362E20436F6D     |216H      6. Com|
 6D756E6963617469 6F6E730D0A1B2661     |munications   &a|
 2B3030323136480D 0A1B26612B303032     |+00216H   &a+002|
 3136482020202020 20382E2050726F62     |16H      8. Prob|
 6C656D2068616E64 6C696E670D0A1B26     |lem handling   &|
 612B303032313648 202020202020392E     |a+00216H      9.|
 20446973706C6179 2061206D656E750D     | Display a menu |
 0A1B26612B303032 3136482020202020     |  &a+00216H     |
 31302E20496E666F 726D6174696F6E20     |10. Information |
 417373697374616E 74206F7074696F6E     |Assistant option|
 730D0A1B26612B30 3032313648202020     |s   &a+00216H   |
 202031312E20436C 69656E7420416363     |  11. Client Acc|
 6573732F34303020 7461736B730D0A1B     |ess/400 tasks   |
 26612B3030323136 480D0A1B26612B30     |&a+00216H   &a+0|
 303231364803ED20 2020202039302E20     |0216H       90. |
 5369676E206F6666 0D0A1B26612B3030     |Sign off   &a+00|
 323136480D0A1B26 612B303032313648     |216H   &a+00216H|
 2053656C65637469 6F6E206F7220636F     | Selection or co|
 6D6D616E640D0A1B 26612B3030323136     |mmand   &a+00216|
 48203D3D3D3E0D0A 1B26612B30303231     |H ===>   &a+0021|
 36480D0A1B26612B 3030323136482046     |6H   &a+00216H F|
 333D457869742020 2046343D50726F6D     |3=Exit   F4=Prom|
 707420202046393D 5265747269657665     |pt   F9=Retrieve|
 2020204631323D43 616E63656C202020     |   F12=Cancel   |
 4631333D496E666F 726D6174696F6E20     |F13=Information |
 417373697374616E 740D0A1B26612B30     |Assistant   &a+0|
 3032313648204632 333D53657420696E     |0216H F23=Set in|
 697469616C206D65 6E750D0A1B26612B     |itial menu   &a+|
 3030323136480D0A 1B26612B30303231     |00216H   &a+0021|
 36480D0CFFEF                          |6H              |

 (... 515-byte print record ...
  IAC EOR)
ToP   noToC   RFC2877 - Page 33
                                   <-- 000A12A001020400 0001FFEF

                                       (10-byte print complete header)
 001412A001010A00 0001000000000000     |                |
 03021B45FFEF                          |   E            |  (ASCII)

 (... 20-byte print record ...
  IAC EOR)
                                   <-- 000A12A001020400 0001FFEF

                                       (10-byte print complete header)
 001112A001010A08 0001000000000000
 00FFEF                            -->

 (... 17-byte NULL print record ...
  ... last of chain ... IAC EOR)
                                   <-- 000A12A001020400 0001FFEF

                                       (10-byte print complete header)

12. Authors' Note

Discussion of this memo should occur in one of these mailing lists: TN3270E List (Roger Fajman raf@cu.nih.gov). Send subscription requests as e-mail with "subscribe tn3270e your_full_name" to listserv@list.nih.gov. Midrange-L List (David Gibbs david@midrange.com). Send subscription requests as email with "subscribe midrange-l your_internet_address" to majordomo@midrange.com. Telnet Working Group Mailing List: Send subscription requests as email with "subscribe telnet-ietf" to telnet-ietf- request@bsdi.com.

13. References

[1] IBM, "IBM 5250 Information Display System, Functions Reference Manual", SA21-9247-6, March 1987. [2] IBM, "5494 Remote Control Unit, Functions Reference", SC30- 3533-04, August 1995. [3] IBM, "AS/400 System API Reference", SC41-5801-01, February 1998.
ToP   noToC   RFC2877 - Page 34
   [4]   IBM, "AS/400 TCP/IP Configuration and Reference", SC41-5420-02,
         September 1998.

   [5]   IBM, "AS/400 Communications Configuration", SC41-5401-00,
         August 1997.

   [6]   IBM, "SNA Formats", GA27-3136-13, November 1993.

   [7]   IBM, "Using the Pageprinter 3812 with System/36 or System/38",
         S544-3343-01, September 1997.

   [8]   Postel, J. and J. Reynolds, "Telnet Protocol Specification",
         STD 8, RFC 854, May 1983.

   [9]   Postel, J. and J. Reynolds, "Telnet Option Specifications", STD
         8, RFC 855, May 1983.

   [10]  Postel, J. and J. Reynolds, "Telnet Binary Transmission", STD
         27, RFC 856, May 1983.

   [11]  VanBokkeln, J., "Telnet Terminal-Type Option", RFC 1091,
         February 1989.

   [12]  Postel, J. and J. Reynolds, "Telnet End of Record Option", RFC
         885, December 1983.

   [13]  Alexander, S., "Telnet Environment Option", RFC 1572, January
         1994.

   [14]  Chmielewski, P., "5250 Telnet Interface", RFC 1205, February
         1991.

   [15]  Postel, J. and J. Reynolds, "Telnet Supress Go Ahead Option",
         STD 29, RFC 858, May 1983.

   [16]  IBM, "AS/400 National Language Support", SC41-5101-01, February
         1998.

   [17]  Data Encryption Standard (DES), Federal Information Processing
         Standards Publication 46-2, January 22, 1988.

   [18]  DES Modes of Operation, Federal Information Processing
         Standards Publication 81, December 1980.

   [19]  Reynolds, J. and J. Postel, "Assigned Numbers", STD 2, RFC
         1700, October 1994.

   [20]  IBM, "IBM Pageprinter 3812 Programming Reference", S544-3268.
ToP   noToC   RFC2877 - Page 35

14. Security Considerations

Security considerations of passwords are discussed in Section 6.

15. Authors' Addresses

Thomas E. Murphy, Jr. IBM Corporation 1701 North Street Endicott, NY 13760 Phone: (607) 752-5482 Fax: (607) 752-5421 EMail: murphyte@us.ibm.com Paul F. Rieth IBM Corporation 1701 North Street Endicott, NY 13760 Phone: (607) 752-5474 Fax: (607) 752-5421 EMail: rieth@us.ibm.com Jeffrey S. Stevens IBM Corporation 1701 North Street Endicott, NY 13760 Phone: (607) 752-5488 Fax: (607) 752-5421 EMail: jssteven@us.ibm.com

16. Relation to Other RFC's

UPDATES This memo is an update to RFC 1205 [14], which describes the 5250 Telnet Interface. This update enhances that description to include device negotiation as well as printer support. This memo makes use of RFC 1572 [13] to enhance communications with 5250 Telnet clients. RFC 1572 is currently on the Standards Track as a Proposed Standard, and is listed in Assigned Numbers [19].
ToP   noToC   RFC2877 - Page 36

17. Full Copyright Statement

Copyright (C) The Internet Society (2000). All Rights Reserved. This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English. The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns. This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Acknowledgement Funding for the RFC Editor function is currently provided by the Internet Society.