6  Definition of charging informationp. 17

6.1  Data description for network slice performance and analytics chargingp. 17

6.1.1  Message contentsp. 17

6.1.1.1  Generalp. 17

The Charging Data Request and Charging Data Response are specified in clause 5.1.2.2.1 of TS 32.290.
Table 6.1.1.1-1 describes the use of these messages for network slice performance and analytics charging.
Message Source Destination
Charging Data RequestCEFCHF
Charging Data ResponseCHFCEF
The following clauses describe the different fields used in the Charging Data messages and the category in the tables is used according to the charging data configuration defined in clause 5.4 of TS 32.240.
Up

6.1.1.2  Charging Data Request messagep. 18

Table 6.1.1.2-1 illustrates the basic structure of a Charging Data Request message from the CEF as used for performance and analytics based charging.
Information Element Category for converged charging Description
Tenant IdentifierOMThis field if present is the identifier of subscriber of network slice.
NF Consumer IdentificationMDescribed in TS 32.290.
NF Functionality
MDescribed in TS 32.290.
NF Name
OCDescribed in TS 32.290.
NF Address
OCDescribed in TS 32.290.
NF PLMN ID
OCDescribed in TS 32.290.
Invocation TimestampMDescribed in TS 32.290.
Invocation Sequence NumberMDescribed in TS 32.290.
One-time EventOCDescribed in TS 32.290.
One-time Event TypeOCDescribed in TS 32.290.
Service Specification InformationOCDescribed in TS 32.290.
Multiple Unit Usage OCDescribed in TS 32.290, with the exception that quota management is not applicable.
Rating Group
MDescribed in TS 32.290
Used Unit Container
OCDescribed in TS 32.290
Local Sequence Number
OMDescribed in TS 32.290
NSPA Container Information
OCThis field holds the network slice performance and analytics container specific information described in clause 6.2.1.3.
NSPA Charging InformationOCThis field holds the network slice information, which is reported to the CHF described in clause 6.2.1.2.
Up

6.1.1.3  Charging data response messagep. 19

Table 6.1.1.3-1 illustrates the basic structure of a Charging Data Response message from the CHF as used for performance and analytics based charging.
Information Element Category for converged charging Description
Session IdentifierOCDescribed in TS 32.290.
Invocation TimestampMDescribed in TS 32.290.
Invocation ResultOCDescribed in TS 32.290.
Invocation Sequence NumberMDescribed in TS 32.290.
Up

6.1.2  Ga message contentsp. 19

Details of the Ga message contents are specified in TS 32.295.

6.1.3  CDR description on the Bns interfacep. 19

6.1.3.1  Generalp. 19

This clause describes the CDR content and format generated for performance and analytics based charging.
The following table provide a brief description of each CDR parameter. The category in the tables is used according to the charging data configuration defined in clause 5.4 of TS 32.240. Full definitions of the CDR parameters, sorted by the name in alphabetical order, are provided in TS 32.298.
Up

6.1.3.2  Network slice performance and analytics CHF CDR datap. 19

If enabled, network slice performance and analytics CDRs shall be produced for each network slice (i.e. S-NSSAI).
The fields of network slice performance and analytics CHF CDR are specified in Table 6.1.3.2-1.
Field Category Description
Record TypeMCHF record.
Recording Network Function IDOMThis field holds the name of the recording entity, i.e. the CHF id.
Tenant IdentifierOMThis field if present is the identifier of subscriber of network slice.
NF Consumer InformationMThis field holds the information of the CEF that used the charging service.
NF FunctionalityMThis field contains the function of the node (i.e. CEF)
NF NameOCThis field holds the name of the CEF used.
NF AddressOCThis field holds the IP Address of the CEF used.
NF PLMN IDOCThis field holds the PLMN identifier (MCC MNC) of the CEF.
List of Multiple Unit Usage OMThis field holds a list of changes in charging conditions for one single Network Slice Selection Assistance. The list is categorized per rating group. Each change is time stamped.
Rating Group
OMThis filed holds the rating group.
Used Unit Container
OCThis field holds the information connected to the reported network slice.
Local Sequence Number
MThis field holds the container sequence number.
NSPA Container Information
OCThis field holds the network slice performance and analytics container specific information described in clause 6.2.1.3.
NSPA Charging InformationOMThis field holds the network slice performance and analytics charging information defined in clause 6.2.1.2.
Record Opening TimeMDescribed in TS 32.298.
DurationMDescribed in TS 32.298.
Record Sequence NumberCDescribed in TS 32.298.
Cause for Record Closing MDescribed in TS 32.298.
Local Record Sequence NumberOMDescribed in TS 32.298.
Record ExtensionsOCDescribed in TS 32.298.
Up

6.2  Network slice performance and analytics charging specific parametersp. 20

6.2.1  Definition of network slice performance and analytics charging informationp. 20

6.2.1.1  Generalp. 20

The Charging Information parameter used for network slice performance and analytics charging is provided in the following clauses.

6.2.1.2  Definition of Performance and Analytics Charging Informationp. 20

Specific charging information used for network slice performance and analytics charging is provided within the Performance and Analytics Charging Information.
The detailed structure of the Performance and Analytics Charging Information can be found in Table 6.2.1.2-1.
Information Element Category Description
Single NSSAIMThis field holds network slice information the performance and analytics information belongs to.
Up

6.2.1.3  Definition of NSPA Container Informationp. 21

Specific charging information used for network slice performance and analytics charging is provided within the NSPA Container Information.
The detailed structure of the NSPA Charging Information can be found in Table 6.2.1.3-1.
Information Element Category Description
Uplink LatencyOCThis field holds uplink latency as described in clause 6.4 of TS 28.541 uLLatency attribute (see NOTE 1).
Downlink LatencyOCThis field holds downlink latency as described in clause 6.4 of TS 28.541 dLLatency attribute.
Uplink ThroughputOCThis field holds uplink throughput of one single network slice as described in clause 6.4 of TS 28.541 uLThptPerSlice attribute (see NOTE 2).
Downlink ThroughputOCThis field holds downlink throughput of one single network slice as described in clause 6.4 of TS 28.541 dLThptPerSlice attribute.
Maximum packet loss rate ULOCThis field holds maximum packet loss rate uplink as described in clause 5.4 of TS 28.541 maxPacketLossRateUl attribute (see NOTE 3).
Maximum packet loss rate DLOCThis field holds maximum packet loss rate downlink as described in clause 5.4 of TS 28.541 maxPacketLossRateDl attribute.
Service Experience statistics dataOCThis field holds service experience statistics data as described in TS 23.288
Number of PDU sessionsOCThis field holds the number of PDU sessions as described in TS 28.554.
Number of registered SubscribersOCThis field holds the number of registered subscribers as described in TS 28.554.
Load levelOCThis field holds the load level as described in TS 23.288.
NOTE 1:
For the back compatible, by default, the Latency holds the uplink latency.
NOTE 2:
For the back compatible, by default, the Throughput holds the uplink throughput.
NOTE 3:
For the back compatible, by default, the Maximum packet loss rate UL holds Maximum packet loss rate uplink.
Up

6.2.2  Formal network slice performance and analytics charging parameter descriptionp. 21

6.2.2.1  Network slice performance and analytics CHF CDR parametersp. 21

The detailed definitions, abstract syntax and encoding of network slice performance and analytics CHF CDRs parameters are specified in TS 32.298.

6.2.2.2  Network slice performance and analytics resources attributesp. 21

The detailed definitions of resources attributes used for network slice performance and analytics charging are specified in TS 32.291.

6.2.3  Detailed message format for converged chargingp. 21

The following clause specifies per Operation Type the charging data that are sent by CEF for network slice performance and analytics converged charging.
The Operation Types are listed in the following order: I (Initial)/T (Termination)/E (Event). Therefore, when all Operation Types are possible it is marked as ITE. If only some Operation Types are allowed for a node, only the appropriate letters are used (i.e. IT or E) as indicated in the Table heading. The omission of an Operation Type for a particular field is marked with "-" (i.e. I-E). Also, when an entire field is not allowed in a node the entire cell is marked as "-".
Table 6.2.3-1 defines the basic structure of the supported fields in the Charging Data Request message for CEF converged charging.
Information Element Performance and Analytics CEF
Supported Operation Types E
Tenant IdentifierE
NF Consumer IdentificationE
Invocation TimestampE
Invocation Sequence NumberE
One-time EventE
One-time Event TypeE
Multiple Unit UsageE
Rating Group
E
Used Unit Container
E
Local Sequence Number
E
NSPA Container Information
E
NSPA Charging Information
Single NSSAI
E
Table 6.2.3-2 defines the basic structure of the supported fields in the Charging Data Response message for CEF converged charging.
Information Element Performance and Analytics CEF
Supported Operation Types E
Session IdentifierE
Invocation TimestampE
Invocation ResultE
Invocation Sequence NumberE
Up

6.3  Bindings for network slice performance and analytics converged chargingp. 22

This mapping between the Information Elements, resource attributes and CHF CDR parameters for network slice performance and analytics converged charging is described in clause 7 of TS 32.291.

$  Change historyp. 23