Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 38.115-2  Word version:  17.3.0

Top   Top   None   None   Next
1…   3…   A…

 

1  Scopep. 17

The present document specifies the Radio Frequency (RF) test methods and conformance requirements for NR Repeater type 2-O. These have been derived from, and are consistent with the radiated requirements for Repeater type 2-O in Repeater specification defined in TS 38.106.
A Repeater type 1-C only has conducted requirements so it does not require compliance to this specification.
A Repeater type 2-O have only radiated requirements so they require compliance to this specification only.
Up

2  Referencesp. 17

The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
  • References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific.
  • For a specific reference, subsequent revisions do not apply.
  • For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in the same Release as the present document.
[1]
TR 21.905: "Vocabulary for 3GPP Specifications"
[2]
TS 38.106: "NR repeater radio transmission and reception"
[3]
Recommendation ITU-R M.1545: "Measurement uncertainty as it applies to test limits for the terrestrial component of International Mobile Telecommunications-2000"
[4]
ITU-R Recommendation SM.329: "Unwanted emissions in the spurious domain"
[5]
TS 38.104: "NR Base Station (BS) radio transmission and reception"
[6]
TS 38.141-2: "NR; Base Station (BS) conformance testing; Part 2: Radiated conformance testing"
[7]
IEC 60 721-3-3: "Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weather protected locations"
[8]
IEC 60 721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Clause 4: Stationary use at non-weather protected locations"
[9]
IEC 60 721: "Classification of environmental conditions"
[10]
IEC 60 068-2-1 (2007): "Environmental testing - Part 2: Tests. Tests A: Cold"
[11]
IEC 60 068-2-2: (2007): "Environmental testing - Part 2: Tests. Tests B: Dry heat"
[12]
IEC 60 068-2-6: (2007): "Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)"
[13]
TR 37.941: "Radio Frequency (RF) conformance testing background for radiated Base Station (BS) requirements"
[14]
TS 38.101-2: "NR; User Equipment (UE) radio transmission and reception; Part 2: Range 2 Standalone".
Up

Up   Top   ToC