consider the entering condition for this event to be satisfied when both condition D1-1 and condition D1-2, as specified below, are fulfilled;
1 >
consider the leaving condition for this event to be satisfied when condition D1-3 or condition D1-4, i.e. at least one of the two, as specified below, are fulfilled;
Inequality D1-1 (Entering condition 1)
Ml1-Hys > Thresh1
Inequality D1-2 (Entering condition 2)
Ml2+Hys < Thresh2
Inequality D1-3 (Leaving condition 1)
Ml1+Hys < Thresh1
Inequality D1-4 (Leaving condition 2)
Ml2-Hys > Thresh2
The variables in the formula are defined as follows:
Ml1
is the distance between UE and a reference location for this event (i.e. referenceLocation1 as defined within reportConfigNR for this event), not taking into account any offsets.
Ml2
is the distance between UE and a reference location for this event (i.e. referenceLocation2 as defined within reportConfigNR for this event), not taking into account any offsets.
Hys
is the hysteresis parameter for this event (i.e. hysteresisLocation as defined within reportConfigNR for this event).
Thresh1
is the threshold for this event defined as a distance, configured with parameter distanceThreshFromReference1, from a reference location configured with parameter referenceLocation1 within reportConfigNR for this event.
Thresh2
is the threshold for this event defined as a distance, configured with parameter distanceThreshFromReference2, from a reference location configured with parameter referenceLocation2 within reportConfigNR for this event.
consider the entering condition for this event to be satisfied when both condition D2-1 and condition D2-2, as specified below, are fulfilled;
1 >
consider the leaving condition for this event to be satisfied when condition D2-3 or condition D2-4, i.e. at least one of the two, as specified below, are fulfilled;
Inequality D2-1 (Entering condition 1)
Ml1-Hys>Thresh1
Inequality D2-2 (Entering condition 2)
Ml2+Hys<Thresh2
Inequality D2-3 (Leaving condition 1)
Ml1+Hys<Thresh1
Inequality D2-4 (Leaving condition 2)
Ml2-Hys>Thresh2
The variables in the formula are defined as follows:
Ml1
is the distance between UE and a moving reference location for this event, not taking into account any offsets. The moving reference location is determined based on referenceLocation1 as defined within reportConfigNR for this event and the corresponding epoch time and satellite ephemeris.
Ml2
is the distance between UE and a moving reference location for this event, not taking into account any offsets. The moving reference location is determined based on referenceLocation2 as defined within reportConfigNR for this event and the corresponding epoch time and satellite ephemeris
Hys
is the hysteresis parameter for this event (i.e. hysteresisLocation as defined within reportConfigNR for this event).
Thresh1
is the threshold for this event defined as a distance, configured with parameter distanceThreshFromReference1, from a moving reference location configured with parameter referenceLocation1 within reportConfigNR for this event.
Thresh2
is the threshold for this event defined as a distance, configured with parameter distanceThreshFromReference2, from a moving reference location configured with parameter referenceLocation2 within reportConfigNR for this event.
consider the entering condition for this event to be satisfied when both condition X1-1 and condition X1-2, as specified below, are fulfilled;
1 >
consider the leaving condition for this event to be satisfied when condition X1-3 or condition X1-4, i.e. at least one of the two, as specified below, is fulfilled;
Inequality X1-1 (Entering condition 1)
Mr + Hys < Thresh1
Inequality X1-2 (Entering condition 2)
Mn + Ofn + Ocn - Hys > Thresh2
Inequality X1-3 (Leaving condition 1)
Mr - Hys > Thresh1
Inequality X1-4 (Leaving condition 2)
Mn + Ofn + Ocn + Hys < Thresh2
The variables in the formula are defined as follows:
Mr
is the measurement result of the serving L2 U2N Relay UE, not taking into account any offsets.
Mn
is the measurement result of the NR cell, not taking into account any offsets.
Ofn
is the measurement object specific offset of the reference signal of the NR cell (i.e. offsetMO as defined within measObjectNR corresponding to the NR cell).
Ocn
is the cell specific offset of the NR cell (i.e. cellIndividualOffset as defined within measObjectNR corresponding to the frequency of the NR cell, or cellIndividualOffset as defined within reportConfigNR), and set to zero if not configured for the cell.
Hys
is the hysteresis parameter for this event.
Thresh1
is the threshold parameter for this event (i.e. x1-Threshold1-Relay as defined within reportConfigNR for this event).
Thresh2
is the threshold parameter for this event (i.e. x1-Threshold2 as defined within reportConfigNR for this event).
Mr
is expressed in dBm.
Mn
is expressed in dBm in case of RSRP, or in dB in case of RSRQ and RS-SINR.
consider the entering condition for this event to be satisfied when both condition Y1-1 and condition Y1-2, as specified below, are fulfilled;
1 >
consider the leaving condition for this event to be satisfied when condition Y1-3 or condition Y1-4, i.e. at least one of the two, as specified below, is fulfilled;
Inequality Y1-1 (Entering condition 1)
Mp + Hys < Thresh1
Inequality Y1-2 (Entering condition 2)
Mr - Hys > Thresh2
Inequality Y1-3 (Leaving condition 1)
Mp - Hys > Thresh1
Inequality Y1-4 (Leaving condition 2)
Mr + Hys < Thresh2
The variables in the formula are defined as follows:
Mp
is the measurement result of the PCell, not taking into account any offsets.
Mr
is the measurement result of the candidate L2 U2N Relay UE, not taking into account any offsets.
Hys
is the hysteresis parameter for this event (i.e. hysteresis as defined within reportConfigInterRAT for this event).
Thresh1
is the threshold parameter for this event (i.e. y1-Threshold1 as defined within reportConfigInterRAT for this event).
Thresh2
is the threshold parameter for this event (i.e. y1-Threshold2-Relay as defined within reportConfigInterRAT for this event).
Mp
is expressed in dBm in case of RSRP, or in dB in case of RSRQ and SINR.
Mr
is expressed in dBm or dB, depending on the measurement quantity of candidate L2 U2N Relay UE.
consider the entering condition for this event to be satisfied when both condition Z1-1 and condition Z1-2, as specified below, are fulfilled;
1 >
consider the leaving condition for this event to be satisfied when condition Z1-3 or condition Z1-4, i.e. at least one of the two, as specified below, is fulfilled;
Inequality Z1-1 (Entering condition 1)
Mr + Hys < Thresh1
Inequality Z1-2 (Entering condition 2)
Mn - Hys > Thresh2
Inequality Z1-3 (Leaving condition 1)
Mr - Hys > Thresh1
Inequality Z1-4 (Leaving condition 2)
Mn + Hys < Thresh2
The variables in the formula are defined as follows:
Mr
is the measurement result of the serving L2 U2N Relay UE, not taking into account any offsets.
Mn
is the measurement result of the candidate L2 U2N Relay UE, not taking into account any offsets.
Hys
is the hysteresis parameter for this event (i.e. hysteresis as defined within reportConfigInterRAT for this event).
Thresh1
is the threshold parameter for this event (i.e. sl-rsrp in z1-Threshold1-Relay as defined within reportConfigInterRAT if the UE measures SL-RSRP, or sd-rsrp in z1-Threshold1-Relay as defined within reportConfigInterRAT if the UE measures SD-RSRP for this event).
Thresh2
is the threshold parameter for this event (i.e. z1-Threshold2-Relay as defined within reportConfigInterRAT for this event).
Mr
is expressed in dBm or dB, depending on the measurement quantity of serving L2 U2N Relay UE.
Mn
is expressed in dBm or dB, depending on the measurement quantity of candidate L2 U2N Relay UE.