Tech-
invite
3GPP
space
IETF
space
21
22
23
24
25
26
27
28
29
31
32
33
34
35
36
37
38
4‑5x
Content for
TR 37.976
Word version: 18.0.0
1…
4…
4
Introduction
5
Performance Metrics
6
Measurement Methodologies
7
Measurement Results from COST2100
8
Measurement Results from CTIA
9
Conclusions
10
Recommendations
A
Test Plan for Anechoic Chamber based candidate methodologies with 3 or more probe antennas
B
LTE MIMO OTA Test Plan
$
Change history
4
Introduction
p. 8
4.1
Background
p. 8
4.2
Study item objective
p. 8
4.3
High Level Requirements
p. 8
4.4
Proposed work plan
p. 8
5
Performance Metrics
p. 11
5.1
Figure of Merits
p. 11
5.1.1
Definition of MIMO Throughput
p. 11
5.1.2
Definition of SNR
p. 11
5.1.2.1
Multiple probe antenna based method
p. 12
5.1.2.2
Reverberation chamber based method
p. 13
5.1.2.3
Two-stage method
p. 13
5.2
Receiver Performance Metrics
p. 13
6
Measurement Methodologies
p. 13
6.1
Fixed Reference Measurement Channels (FRCs)
p. 13
6.2
MIMO Channel Models
p. 13
6.3
Downlink Measurement Methodologies
p. 17
6.3.1
Methodologies based on Anechoic RF Chamber
p. 18
6.3.1.1
Candidate Solution 1
p. 18
6.3.1.1.1
Concept and Configuration
p. 19
6.3.1.1.2
Test Conditions
p. 20
6.3.1.2
Candidate Solution 2
p. 21
6.3.1.2.1
Concept and Configuration
p. 22
6.3.1.2.1A
Scalability of the methodology
p. 23
6.3.1.2.2
Test Conditions
p. 24
6.3.1.3
Candidate Solution 3
p. 25
6.3.1.3.1
Concept and Configuration
p. 25
6.3.1.3.2
Test Conditions
p. 26
6.3.1.4
Candidate Solution 4
p. 27
6.3.1.4.1
Concept and Configuration
p. 27
6.3.1.5
Candidate Solution 5
p. 28
6.3.1.5.1
Concept and Configuration
p. 28
6.3.1.5.2
Test Conditions
p. 31
6.3.1.Y
Downlink Transmission Modes
p. 32
6.3.2
Methodologies based on Reverberation Chamber
p. 32
6.3.2.1
Candidate Solution 1
p. 32
6.3.2.1.1
Concept and Configuration
p. 33
6.3.2.1.2
Test Conditions
p. 34
6.3.2.2
Candidate Solution 2
p. 35
6.3.2.2.1
Concept and Configuration
p. 36
6.3.2.2.2
Test Conditions
p. 36
6.3.2.Y
Downlink Transmission Modes
p. 37
7
Measurement Results from COST2100
p. 37
7.1
Reference Measurement Channels
p. 37
8
Measurement Results from CTIA
p. 37
8.1
Reference Measurement Channels
p. 37
9
Conclusions
p. 38
9.1
Comparison of Candidate Methodologies
p. 38
9.1.1
Definitions of rows in the table
p. 41
9.2
Lessons learnt and conclusions
p. 42
10
Recommendations
p. 43
A
Test Plan for Anechoic Chamber based candidate methodologies with 3 or more probe antennas
p. 45
A.1
Introduction
p. 45
A.2
Test setup
p. 45
A.2.1
Calibration
p. 46
A.2.1.1
Calibration Check
p. 46
A.2.2
Radio Channel Conditions
p. 47
A.2.2.1
Average channel power
p. 47
A.3
Test Procedure
p. 48
A.3.1
HSDPA connection settings
p. 48
A.3.1.1
FRC
p. 48
A.3.2
Method of test
p. 49
B
LTE MIMO OTA Test Plan
p. 51
B.1
Test Objectives
p. 51
B.2
Test Setup
p. 51
B.2.1
Figure of Merits (FOMs)
p. 54
B.2.2
Channel Models
p. 55
B.2.3
Antenna Probes
p. 55
B.2.4
eNodeB Emulator Parameter Settings
p. 56
B.2.5
Reference DUTs Configurations
p. 57
B.3
Calibration of Test System
p. 58
B.3.1
Calibration Procedure for Anechoic-chamber based methodologies
p. 58
B.3.1.1
Probe power calibration
p. 58
B.3.1.2
Channel power calibration
p. 59
B.3.1.3
Calibration check
p. 59
B.3.2
Calibration Procedure for Reverberation-chamber based methodologies
p. 60
B.3.2.1
Tuning Reverberation Chamber to Specific Channel Model
p. 61
B.3.2.2
Average Path Loss Measurement
p. 61
B.3.3
Calibration Procedure for 2-Stage methodologies
p. 62
B.3.3.1
Antenna pattern measurement calibration in stage I
p. 62
B.3.3.3
Power calibration for results comparison from different OTA test methods
p. 64
B.3.4
Calibration Procedure for antenna pattern based methodologies
p. 64
B.3.5
Calibration Procedure for two-channel method
p. 65
B.4
Test Procedure
p. 65
B.4.1
Test Procedure 1
p. 65
B.4.1A
Test Procedure 1A (Reverberation Chamber Based Methodologies)
p. 67
B.4.2
Test Procedure 2
p. 67
B.4.3
Test Procedure 3 (Antenna spatial correlation measurement)
p. 68
B.4.4
Test Procedure 4 (Two-stage throughput)
p. 69
B.4.5
Test Procedure 5 for two-channel method
p. 71
$
Change history
p. 72