Test pattern
Spectrum mask and emission requirement shall be tested both with a consecutive series of
"0" and an alternating sequence of
"0" and
"1".
Emission requirement below noise floor
As a general rule, the resolution bandwidth of the measuring equipment should be equal to the measurement bandwidth. However, to improve measurement accuracy and sensitivity when measuring close to or below the noise floor, the resolution bandwidth may be smaller than the measurement bandwidth. When the resolution bandwidth is smaller than the measurement bandwidth, the result should be integrated over the measurement bandwidth in order to obtain the equivalent noise bandwidth of the measurement bandwidth.
Conversion between modulated and CW for IM measurement
The requirement for IM3 below 1 GHz shall be relaxed 15 dB and tested with CW interferers at the specified levels.
The requirement for IM3 above 1 GHz shall be relaxed 5 dB and tested with CW interferers at the specified levels.
The requirement for IM5 or higher below 1 GHz shall be relaxed 10 dB and tested with CW interferers at the specified levels.
The requirement for IM5 or higher above 1 GHz shall be relaxed 0 dB and tested with CW interferers at the specified levels.
Example: A -130 dBm/100 kHz requirement below 1 GHz with two WCDMA-modulated carriers at 43 dBm is converted to a -115 dBm requirement with two CW carriers at 43 dBm.