Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 38.321  Word version:  18.0.0

Top   Top   Up   Prev   None
1…   4…   5…   5.1.2…   5.2…   5.4…   5.4.4…   5.5…   5.9…   5.18…   5.18.18…   5.19…   5.22…   5.22.1.4…   5.22.2…   5.23…   6…   6.1.3…   6.1.3.8…   6.1.3.11…   6.1.3.17…   6.1.3.21…   6.1.3.26…   6.1.3.31…   6.1.3.37…   6.1.3.42…   6.1.3.49…   6.1.3.53…   6.1.3.59…   6.1.3.64…   6.1.3.70…   6.1.3.74…   6.1.3.79…   6.1.4…   6.2…   7…

 

7  Variables and constantsp. 298

7.1  RNTI valuesp. 298

RNTI values are presented in Table 7.1-1.
Value (hexa-decimal) RNTI
0000N/A
0001-FFF2RA-RNTI, MSGB-RNTI, Temporary C-RNTI, C-RNTI, CI-RNTI, MCS-C-RNTI, CS-RNTI, TPC-PUCCH-RNTI, TPC-PUSCH-RNTI, TPC-SRS-RNTI, INT-RNTI, SFI-RNTI, SP-CSI-RNTI, PS-RNTI, SL-RNTI, SL-CS-RNTI, SL-PRS-RNTI, SL-PRS-CS-RNTI, SL Semi-Persistent Scheduling V-RNTI, AI-RNTI, G-RNTI, G-CS-RNTI, CG-SDT-CS-RNTI, and NCR-RNTI
FFF3-FFFAReserved
FFFBMulticast MCCH-RNTI
FFFCPEI-RNTI
FFFDMCCH-RNTI
FFFEP-RNTI
FFFFSI-RNTI
RNTI Usage Transport Channel Logical Channel
P-RNTIPaging and System Information change notificationPCHPCCH
SI-RNTIBroadcast of System InformationDL-SCHBCCH
RA-RNTIRandom Access ResponseDL-SCHN/A
MSGB-RNTIRandom Access Response for 2-step RA typeDL-SCHCCCH, DCCH, DTCH
Temporary C-RNTIContention Resolution (when no valid C-RNTI is available)DL-SCHCCCH, DCCH, DTCH
Temporary C-RNTIMsg3 transmissionUL-SCHCCCH, DCCH, DTCH
C-RNTI, MCS-C-RNTIDynamically scheduled unicast transmissionUL-SCHDCCH, DTCH
C-RNTIDynamically scheduled unicast transmissionDL-SCHCCCH, DCCH, DTCH
NCR-RNTITransmission of Side Control Information for NCR operationN/AN/A
MCS-C-RNTIDynamically scheduled unicast transmissionDL-SCHDCCH, DTCH
C-RNTITriggering of PDCCH ordered random accessN/AN/A
C-RNTIDynamically scheduled PTP retransmission for initial PTM transmission for multicast MBS.DL-SCHMTCH
CG-SDT-CS-RNTIDynamically scheduled unicast transmission (retransmission)UL-SCHCCCH, DCCH, DTCH
CS-RNTIConfigured scheduled unicast transmission (activation, reactivation and retransmission)DL-SCH, UL-SCHDCCH, DTCH
CS-RNTIConfigured scheduled unicast transmission (deactivation)N/AN/A
CS-RNTIConfigured scheduled unicast transmission (PTP retransmission for initial PTM transmission)DL-SCHMTCH
CS-RNTIConfigured scheduled unicast transmission (MBS SPS deactivation)N/AN/A
G-CS-RNTIConfigured scheduled multicast transmission (activation, reactivation and retransmission)DL-SCHMTCH
G-CS-RNTIConfigured scheduled multicast transmission (deactivation)N/AN/A
TPC-PUCCH-RNTIPUCCH power controlN/AN/A
TPC-PUSCH-RNTIPUSCH power controlN/AN/A
TPC-SRS-RNTISRS trigger and power controlN/AN/A
INT-RNTIIndication pre-emption in DLN/AN/A
SFI-RNTISlot Format Indication on the given cellN/AN/A
SP-CSI-RNTIActivation of Semi-persistent CSI reporting on PUSCHN/AN/A
CI-RNTICancellation indication in ULN/AN/A
PS-RNTIDCP to indicate whether to start drx-onDurationTimer for associated DRX cycleN/AN/A
SL-RNTIDynamically scheduled sidelink transmissionSL-SCHSCCH, STCH
SL-CS-RNTIConfigured scheduled sidelink transmission (activation, reactivation and retransmission)SL-SCHSCCH, STCH
SL-CS-RNTIConfigured scheduled sidelink transmission (deactivation)N/AN/A
SL-PRS-RNTIDynamically scheduled sidelink PRS transmissionN/AN/A
SL-PRS-CS-RNTIConfigured scheduled sidelink PRS transmission (activation and reactivation)N/AN/A
SL-PRS-CS-RNTIConfigured scheduled sidelink PRS transmission (deactivation)N/AN/A
SL Semi-Persistent Scheduling V-RNTI (NOTE 2)Semi-Persistently scheduled sidelink transmission for V2X sidelink communication (activation, reactivation and retransmission)SL-SCHSTCH
SL Semi-Persistent Scheduling V-RNTI (NOTE 2)Semi-Persistently scheduled sidelink transmission for V2X sidelink communication (deactivation)N/AN/A
AI-RNTIAvailability indication on the given cellN/AN/A
G-RNTIDynamically scheduled MBS PTM transmissionDL-SCHMTCH
MCCH-RNTIDynamically scheduled MCCH signalling and MCCH change notificationDL-SCHMCCH
PEI-RNTIPaging Early IndicationN/AN/A
NOTE 1:
The usage of MCS-C-RNTI is equivalent to that of C-RNTI in MAC procedures (except for the C-RNTI MAC CE).
NOTE 2:
The MAC entity uses SL Semi-Persistent Scheduling V-RNTI to control semi-persistently scheduled sidelink transmission on SL-SCH for V2X sidelink communication as specified in clause 5.14.1.1 of TS 36.321.
NOTE 3:
The usage of CG-SDT-CS-RNTI is equivalent to that of CS-RNTI when there is an CG-SDT procedure ongoing.
Up

7.2  Backoff Parameter valuesp. 301

Backoff Parameter values are presented in Table 7.2-1.
Index Backoff Parameter value (ms)
05
110
220
330
440
560
680
7120
8160
9240
10320
11480
12960
131920
14Reserved
15Reserved
Up

7.3  DELTA_PREAMBLE valuesp. 301

The DELTA_PREAMBLE preamble format based power offset values are presented in Table 7.3-1 and Table 7.3-2.
Preamble Format DELTA_PREAMBLE values
0 0 dB
1-3 dB
2-6 dB
3 0 dB
Preamble Format DELTA_PREAMBLE values (dB)
A18 + 3 × μ
A25 + 3 × μ
A33 + 3 × μ
B18 + 3 × μ
B25 + 3 × μ
B33 + 3 × μ
B43 × μ
C011 + 3 × μ
C25 + 3 × μ
where μ is the sub-carrier spacing configuration determined by msg1-SubcarrierSpacing or msgA-SubcarrierSpacing, as specified in TS 38.331 and Table 4.2-1 in TS 38.211, and the preamble formats are given by prach-ConfigurationIndex or msgA-PRACH-ConfigurationIndex, as specified in TS 38.331 and Tables 6.3.3.2-2 to 6.3.3.2-4 in TS 38.211.
Up

7.4  PRACH Mask Index valuesp. 302

PRACH Mask Index/
msgA-SSB-SharedRO-MaskIndex/
ssb-SharedRO-MaskIndex
Allowed PRACH occasion(s) of SSB
0All
1PRACH occasion index 1
2PRACH occasion index 2
3PRACH occasion index 3
4PRACH occasion index 4
5PRACH occasion index 5
6PRACH occasion index 6
7PRACH occasion index 7
8PRACH occasion index 8
9Every even PRACH occasion
10Every odd PRACH occasion
11Reserved
12Reserved
13Reserved
14Reserved
15Reserved
Up

$  Change historyp. 303


Up   Top